Misc 777 Flashcards

1
Q

Min crew complement

A

10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Total pax

A

344

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Total sky couch

A

20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Door Closed
FA check

A

No items in door frame
Push down on handle
RED Arrow continuous

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Door Arming

A

Cover lever cover
Arming lever in the Red band
Yellow girt bar indicators

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Disarming

A

Cover lever cover
Arming lever in Green band
Black girt bar indicators

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Slide raft capacity

A

1&2 L&R
Cap 65
Overload 81

4 L&R
Cap 57
Overload 71

5 L&R
Cap 64
Overload 79

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

CSCP/CACP location

A

Door 1L CSCP
Door 2L CACP
Door 5R CACP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

SATCOM location

A

1 at VCC
1 at 4R

Note - call F/D first to ask permission and connect

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

PA all cabin’s

A

46 + PTT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Direct access PA switch location

777 …. Check

A

1L
2L
4L

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Sky couch restrictions

A

Max 4 seat mode
Max 3 couch mode
Inf 0-2 accompanied
2-14 behind or directly adjacent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Infant Pod pre-flight check

A

Req No. provided
Seal white- clean
Seal orange-used

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Infant harness size’s

A

Sm 0-5kg <65cm
Med 5-10kg 65-85cm
Leg 10-18kg. 85-110cm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Check for infant harness kits

A

Req. No. provided

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Pre ldg sky couch & pods

A

Wake 15min prior top
Leg rest stowed
Return pod and harness stowed with orange seal

Unserviceable - Red tag
Cabin log
Return to stowage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

O2 flowing to mask

A

In-line flow indicator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Type of O2 system

A

Gaseous

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

How to turn off O2 system

A

Lift flap and replace pin

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

777
Mask deployment

A

13500

One LO/HI chime

Tape will play

21
Q

Communicator announcement for fire fighting

A

“Attention flight attendant,would the ISM report to……area.”

22
Q

At what angle is the BCF unusable

A

60degrees

23
Q

Fly deck lithium fire PA

A

Flight attendant report to the flight deck immediately

24
Q

Alternative evac command from F/D

A

Seatbelt sign on and off three times causing 6 chime’s

25
Q

Emergency light duration

A

Approximately 20min

26
Q

When emergency light button pushed

A

All lights illuminated inside and out

27
Q

Opening an armed door illuminates emergency lights

A

At that door inside and out

28
Q

Emergency light test switch is located at

A

1L and 5R

On approximately 1 min

29
Q

Lights on outside illuminate what area

A

Base of slide

There are also slight lights

30
Q

Flight deck indications of toilet smoke alarm

A

Caution alarm sounds
‘SMOKE LAVATORY’ EICAS msg

31
Q

Cabin smoke indications toilet alarm

A

Smoke detector Red light
Smoke detector Alarm sounds
Amber call light flashes above toilet door
Nearest ACP Amber call light flashes
Nearest ACP continuous Hi chime
‘SMOKE DETECTED’ and location on CSCP and CACP

32
Q

How to rest smoke indicators

A

Push Ambercall light
Push clear on CSCP or CACP

Red light stays illuminated until smoke has cleared

33
Q

Scott/AVOX portable O2 bottle
Pre flight check

A

Min 1600psi
Mask and tubing attached to HI/outlet
Required No provided

34
Q

Pre flight check Aisle chair

A

Secured
Serviceable

35
Q

Pre flight check
Torch 777

A

Red light flashing every 3-4 seconds

36
Q

777 Smoke hood
Pre flight check

A

Look through clear lid check inside
Check replace by date
Check green plastic seals
Both seals broken remove check indicator
Blue-serviceable
Pink-36hrs from discovery
Cabin log

37
Q

Pax mask

A

Biz 3 outboard
5 inboard

PE 3 Outboard
5 inboard
23ab jk 4
30dg 3

Econ 3 outboard double seat
4 outboard triple seat’s
5 inboard quadruple seat
48abc 9 mask. 48hjk 7 mask
23defg 8 mask
35defg 8 mask
48defg 8 mask

2 for toilet and crew seat

38
Q

777

OFAR smoke indications

A

Ceiling horn
Alert horn
Detector alarm
Detector red light
Amber airflow off light
Area light

39
Q

OFCR & OFAR smoke indications in the cabin

A

Amber light above door flashes
Nearest ACP flashes
Continuous HI chime

CSCP CACP alert msg

40
Q

Reset smoke indications for overhead rest in the overhead rest

A

Push horn shutoff

41
Q

Medical power outlet 777 and point location

A

9A - PSU
26A - Sidewall
36Abc - Sidewall between row 36 and 37
49Abc - Sidewall
58AB - Sidewall

42
Q

Where is the escape hatch in OFAR

A

Under bunk 6

43
Q

Alert Horn sounds 777 OFAR

A

Smoke - Pulsating
Decompression - Continuous

44
Q

How to reset cabin smoke indications

A

Push Amber call light above rest door

45
Q

777

How to reset Smoke Detection System when smoke has cleared Overhead rest plus warnings

A

Push Airflow/Smoke Reset button

Push for 2sec

Warning - don’t push until fire out and smoke cleared ( may allow smoke to enter the cabin)

Failure to reset may incur subsequent indications

46
Q

Supply Airflow Off Light
Check and write ref page with regards to 5 Lo/Hi chimes

A

Amber when airflow off
Amber when below 25,000’
Amber when smoke detected
Amber when air supply valves turned off and exhaust valves open
Five LO/HI chime’s when airflow commanded closed

47
Q

The alert horn in crew rest smoke vs decompression

A

Smoke - pulsating
Decompression - continuous

48
Q

Chimes in OFAR for airflow off

A

5 LO/HI when commanded closed
Amber light on when below 25,000’

49
Q

Water shutoff valve at 2L shuts off water supply

A

Forward of 2L/R