Q7 Flashcards

(75 cards)

1
Q

Which statement is correct when performing a rope rescue with the LSR?

A

Rescuer remains clipped in when going through a window with a victim

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

You arrive home after a long day from Proby School and you put your favorite Salisbury Steak TV dinner in the oven but fall asleep on the couch. You wake up to the FDNY forcing your door. What is the appropriate 10-code for this?

A

10-26, Food on Stove

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is correct in regards to Foam Operations?

A

Cannot mix 2 low expansion foam concentrates

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which of the following is INCORRECT about the 4 primary methods of extinguishment with foam?

A

Controls – Foam controls the spill and the direction of the stream

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How far should the eye of the hook to the EXO measurement be?

A

8”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When passing through studs with the swim move, what is correct?

A

Right knee, Right Shoulder, Then Head

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the tool assignments for the 1st due Roof at a fire on the 15th Floor of a 20 Floor High Rise Multi-Dwelling?

A

KO Curtain, Hydra-Ram, & Halligan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

(T/F) When using the FAST Pak, you use the Low-Pressure Hose to connect with the downed member’s UAC.

A

False (High Pressure Hose connects to the UAC.)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

(T/F) When In-Line Pumping, the ECC should be mindful of other companies responding from the opposite side of the street that may block the hydrant.

A

False (When inline pumping, the hydrant is before the fire building & there is no worry of opposing traffic being an issue. If it said backstretch instead, True.)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is correct when using the FAST Pak?

A

You can disconnect the high-pressure hose from a downed member’s cylinder when both pressures are equalized.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

(T/F) When placing portable ladders along fire escapes to assist victim egress, you should lash them to the fire escape if time permits.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the correct length of the PSS rope?

A

50 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the correct Handie-Talkie code for Ladder 10 Roof position?

A

7010003 (Engine = 5 [1-6, Officer, Chauffeur, Nozzle, Backup, Control, Door/Spare]; Ladder = 7 [1-6, Officer, Chauffeur, Roof, OV, Irons, Can])

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is INCORRECT for 1st due OV at a 20-story Fireproof Multi-Dwelling?

A

Take the fire escape to the fire floor to VEIS. (No Fire Escapes on Fireproof Multi-Dwellings.)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the 10-Code for Carbon Monoxide?

A

10-38

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is INCORRECT about 1st due Roof position at a Fireproof Multi-Dwelling?

A

In the apartment above the fire apartment, you would start closing the door and opening the window to simulate wind conditions and report them.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What is INCORRECT about packaging & removing a downed member?

A

Sit the member upright and face his legs towards the exit. (Should be back to the exit.)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

(T/F) The 125 GPM foam nozzle works with the 1 ¾” and 2 ½” hoses.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What is the correct tool assignment for 2nd due OV at a taxpayer fire?

A

Maul & Halligan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

What is a horizontal building member that supports the weight above windows or doors?

A

Lintel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What is the 10-code for Carbon Monoxide?

A

10-38

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

When the fire escape becomes overcrowded, can the firefighter lash ladders to the fire escape if time permits?

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

The foam eductor can only be used at 125 GPM with a 2 ½ inch hose?

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

At a taxpayer with high heat and heavy smoke visible in multiple store fronts but no visible flames, what can firefighters suspect?

A

Fire in the cellar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Which of the following is incorrect about the 2nd due roof man's responsibilities?
(Answer Needed)
26
The presence of a standpipe does not mandate that the engine company must use it for water operations.
True
27
When does the digital gauge go to sleep after no water flow?
15 min
28
Which of the following does the 2nd due OV bring to a FPMD?
6ft Hook
29
What is incorrect about operations regarding rescue with an LSR?
Rescuing member remains attached to the LSR when entering the apartment to search for the victim (rescuing member does not enter the apartment)
30
You can cut bolts, case hardened locks, and wires with bolt cutters?
False
31
Which of the following is incorrect about the foam eductor?
You can put the eductor two lengths away from the rig
32
What is the supporting member above doors and windows called?
Lintel
33
Which of the following is correct in regard to apparatus positioning at a car fire?
Operating engine can be positioned beyond the vehicle on fire, if the engine will be threatened by fire exposure, and a minimum of one, ideally two blocking apparatus to be placed in the way of oncoming traffic.
34
In regards to the 2 in 2 out rule, if there is a 5-man ladder and a 4-man engine company, who will be the safety team?
LCC and control
35
What is the correct order for the FAST pack in order of quickest application?
RHFU
36
You arrive home after a long day of proby school and you put your favorite Salisbury steak TV dinner in the oven but fall asleep on the couch. You wake up to the FDNY forcing open your door. What is the appropriate 10-code for this?
10-26
37
(T or F) At a fire, if the fire escape becomes overcrowded you would lash the ladders to the fire escape if time permits to alleviate crowding.
True
38
(T or F) The 125 GPM foam nozzle can be used on either the 1 3/4 inch hose or the 2 1/2 inch hose.
True
39
What is the 10-code for a high-rise residential?
10-77
40
(T or F) When using the FAST-Pak you use the low-pressure hose to connect to a downed member's UAC?
False
41
Which Statement is INCORRECT regarding High Rise Fireproof Multiple Dwelling?
Fire extension is a major concern
42
What is True About ventilation?
Vent the window off the fire escape before the one on the fire escape
43
(T or F) The presence of a standpipe mandates its use by an Engine company in a high-rise fireproof multiple dwelling in a building.
False
44
What is incorrect about the 2nd due roof Firefighter at a High Rise Fireproof Multiple Dwelling?
They use the evacuation stairs to access the floor above the fire apartment
45
During relay operations, the apparatus supplying water to the operating apparatus is called the pumper.
Supply
46
Who is the safety team when two 5-man engine companies are at the scene?
Backup and Control of the second arriving engine
47
What is correct about airbag usage?
The rated tonnage of an airbag can be lifted 1 inch (it can lift half the tonnage all the way)
48
(T or F) Bolt cutters can be used on case-hardened locks.
False
49
Which of the following is not a method of extinguishment regarding foam operations?
Controls (C is cools)
50
What is incorrect about the FAST-PAK?
When connecting to a downed member's SCBA, you would use the 5-foot low-pressure hose (it is 6-foot)
51
What is correct about the apparatus placement at an auto accident?
The apparatus can be beyond the vehicle with the blocking truck against oncoming traffic protecting the incident.
52
What is incorrect about single slide?
Empty the contents of the bag on the roof and then throw the bag off the roof to the street.
53
What is NOT in the standpipe kit bag?
1 3/4” nozzle with 15/16 MST
54
What is the correct tool assignment for the first due Roof Firefighter at a fireproof multiple dwelling?
KO Curtain, Halligan, Hydra-Ram
55
(T or F) When venting the window with a portable Ladder and no other member available, you grab it by the rungs and throw it into the window leaving your hands on the rungs?
False (Once you throw it into the window, you remove your hands quickly and stay clear of falling debris)
56
The digital inline pressure gauge will go to sleep mode after how many minutes?
15
57
The digital inline pressure gauge will flash LO Batt when how many minutes are remaining?
10
58
Which is incorrect about the eductor during foam operations?
Eductor can be attached two lengths away from the rig
59
You arrive home after a long day of proby school and you put your favorite Salisbury steak TV dinner in the oven but fall asleep on the couch. You wake up to the FDNY forcing open your door. What is the appropriate 10-code for this?
10-26
60
(T/F) At a fire, if the fire escape becomes overcrowded you would lash the ladders to the fire escape if time permits to alleviate crowding.
True
61
(T/F) The 125 GPM foam nozzle can be used on either the 1 3/4 inch hose or the 2 1/2 inch hose.
True
62
What is the 10-code for a high-rise residential?
10-77
63
Which Statement is incorrect regarding High Rise Fireproof Multiple Dwelling?
Fire extension is a major concern
64
(T/F) The presence of a standpipe mandates its use by an Engine company in a high-rise fireproof multiple dwelling in a building.
False
65
Who is the safety team when two 5-man engine companies are at the scene?
Backup and Control of the second arriving engine
66
(T/F) Bolt cutters can be used on cables/wires but not on case-hardened locks.
True
67
What is incorrect about the FAST-PAK?
When connecting to a downed member's SCBA, you would use the 5-foot low-pressure hose
68
What is correct about the apparatus placement at an auto accident?
The apparatus can be beyond the vehicle with the blocking truck against oncoming traffic protecting the incident.
69
What is incorrect about single slide?
Empty the contents of the bag on the roof and then throw the bag off the roof to the street.
70
What tool is incorrect for the first due Roof Firefighter at a fireproof multiple dwelling?
Halligan Hook (Correct: KO Curtain, Halligan, Hydra Ram)
71
(T or F) When venting the window with a portable ladder and no other member available, you grab it by the rungs and throw it into the window leaving your hands on the rungs?
False (Once you throw it into the window, you remove your hands quickly and stay clear of falling debris)
72
How far should the eye of the hook to the EXO measurement be?
8”
73
What is the correct length of the PSS rope?
50 feet
74
What is the correct way to give air to a downed member using the FastPak High Pressure Hose?
Connect to UAC
75
What is correct about the 2nd due roof FF at a cellar fire at taxpayer?