Radiation Protection Program Flashcards

is a systematic arrangement which is aimed at providing adequate consideration of radiation protection and safety measures in an x-ray facility. (56 cards)

1
Q

is a systematic arrangement which is aimed at providing adequate consideration of radiation protection and safety measures in an x-ray facility.

A

Radiation Protection Program

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

is responsible for recommending or approving corrective actions, identifyingradiation safetyproblems, initiating action, and ensuring compliance with regulations.

A

Radiation Safety officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Enforceable order issued by a public authority (under the powers conferred to it by one or more statutes) to an individual or an organization to take certain corrective action, or to refrain from an activity.

A

Administrative order

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

In the Philippines, there are about ____ x-ray facilities doing diagnostic and interventional procedures.

A

3,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In ____ , the International Atomic Energy Agency (IAEA), published the Basic Safety Standards entitled “Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources”.

A

1996

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

In 1996, the International Atomic Energy Agency (IAEA), published the Basic Safety Standards entitled __________________________________.

A

“Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

This standard contains recommendations on the safe use of radiation sources to serve as a guide in the harmonization of standards for radiation regulation bodies of its member states.

A

“Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

To address the need for harmonization of standards with the IAEA, in 2004, the Department of Health adopted the international standard with the issuance of the Administrative Order (AO) No. ____

A

(AO) No. 149

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

To address the need for harmonization of standards with the IAEA, in _____, the Department of Health adopted the international standard with the issuance of the Administrative Order (AO) No. 149

A

2004

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The Department of Health (DOH) ________ s. 2004 (Manual on Basic Radiation Protection and Safety of X-ray Sources) was also issued as an integral part of AO.149.

A

Circular No. 323

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

TRUE OR FALSE: All x-ray facilities shall secure an authorization from the FDA.

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

TRUE OR FALSE: No x-ray facility shall be allowed to operate without a valid authorization issued by the FDA.

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

TRUE OR FALSE:
Any authorized officer or organization applying for authorization:
Shall NOT submit to the FDA the relevant information necessary to support the application for an authorization.

A

FALSE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

TRUE OR FALSE:
Any authorized officer or organization applying for authorization: Shall refrain from carrying out any actions/activities pertaining to the use of the x-ray equipment until the authorization is issued

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

TRUE OR FALSE:
Any authorized officer or organization applying for authorization: Shall NOT assess the nature, likelihood, and magnitude of the expected exposures due to the x-ray machines and shall take all necessary measures for protection and safety.

A

FALSE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

TRUE OR FALSE:
Any authorized officer or organization applying for authorization: Shall have a safety assessment plan made and submitted to the FDA as part of the application.

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

TRUE OR FALSE: All x-ray facilities shall comply with the existing regulations issued by the FDA.

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

TRUE OR FALSE: The x-ray facility shall follow the procedural guidelines set by the FDA in securing the relevant authorization.

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

TRUE OR FALSE: All radiologic procedures shall be done with the most appropriate device that will result in the optimum diagnostic image

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

X-ray Service Category: Chest for Heart and Lungs

A

General Radiography Machine with tube currents of at least 100 mA except for high frequency inverter type x-ray machines and emerging technologies conforming with internationally accepted standards

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

X-ray Service Category: Chest for Heart and Lungs

A

Chest, heart and lungs examinations procedures only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

X-ray Service Category: Level One

A

General Radiography Machine with tube currents of at least 100 mA except for high frequency inverter type x-ray machines and emerging technologies conforming with internationally accepted standards

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

X-ray Service Category: Level One

A

skeletal radiography and abdomen

24
Q

X-ray Service Category: Level Two

A

General Radiography Machine with tube currents of at least 200 mA and/or Radiography/Fluoroscopy System
Helical Computed Tomography Machine

25
X-ray Service Category: Level Two
All of Level one plus radiographic examinations with contrast procedures except interventional radiology
26
X-ray Service Category: Level Three
General Radiography/Fluoroscopy System and/or at least 16 slice Computed Tomography Machine
27
X-ray Service Category: Level Three
All of Level two plus interventional radiology except cardiac catheterization procedures
28
X-ray Service Category: Specialized
Computed Tomography Mammography Cardiac Catheterization Lithotripsy Bone Densitometry Tumor Localization and Simulation
29
The RPO shall either be a _________ OR ________.
diagnostic radiology medical physicist or a radiologic technologist.
30
He/she shall have the authority to stop any activity that may endanger health and safety.
RPO
31
For radiologic technologist to be RPO, he/she shall have completed an appropriate training in radiation protection conducted by an organization recognized by the ________.
FDA
32
A ______ radiologic technologist shall be appointed in a facility.
chief radiologic technologist
33
At least ______ full time radiologic/x-ray technologist per 8-hour shift shall be hired per machine.
one (1)
34
X-ray room for x-ray machines not equipped with radiographic table shall have a minimum width of ____ meters and minimum length of ____ meters.
2.5 & 3.0
35
X-ray room for x-ray machine equipped with radiographic table shall have a minimum width of ____ meters and minimum length of ____meters.
3.5 & 4.0
36
X-ray room for x-ray machine equipped with radiographic/ fluoroscopic machine shall have a minimum width of _____meters and minimum length of _____ meters.
4.5 & 5.0
37
Door leading to the x-ray room must be lined with at least ___ mm (1/6 inch) thick lead sheet to a height of at least ___ meters from the floor/ground outside.
1.5 & 2
38
The base of the examination room window/s shall be elevated to a height of at least __ meters from the floor/ground outside the x-ray examination.
2
39
A red warning light bulb that is automatically illuminated when the x-ray machine is switched on shall be installed ______ the x-ray examination room above the x-ray room door.
outside
40
The warning notice shall be on a ____mm x 270 mm white background.
180mm x 270mm
41
TRUE OR FALSE: Adequate ventilation shall be provided inside the x-ray examination room
TRUE
42
TRUE OR FALSE: The room shall be provided with adequate shielding from scattered and transmitted x-rays.
TRUE
43
DARKROOM: For manual processing, processing tanks consisting of master tank _____ insert tanks made of stainless steel or fiber glass shall be provided.
two (2) tanks
44
DARKROOM: A luminous interval timer/digital timer shall be provided.
YES
45
DARKROOM: A darkroom thermometer or digital thermometer or alcohol thermometer shall be provided
YES
46
DARKROOM: A standard safelight with _____ watt light bulb shall be provided.
10-15 watt
47
DARKROOM: The safelight housing shall be provided with a safelight filter made of glass or hard plastic, tinted with amber or red and which does not fog a pre-exposed film within 45 seconds.
YES
48
DARKROOM: The safelight housing shall be installed not lower than ___ feet from the working table and the processing tanks.
4 FT
49
Films shall be stored _______ on its end. This prevents marks on film because of pressure due to its weight.
vertically
50
ACCESSORIES: A set of contact gonad shields with a minimum lead equivalence of ___ mm lead shall be provided.
1.5 mm
51
ACCESSORIES: A lead rubber apron, with lead equivalence of ___ mm shall be provided.
0.25 mm
52
ACCESSORIES: A _____to measure the thickness of the patient
caliper
53
ACCESSORIES: For a fixed protective barrier, it shall be made of _____cm (6 inches) poured concrete or _____mm thick lead sheets.
15.25cm & 1.50
54
ACCESSORIES: For a movable protective barrier, it shall be made of ____mm thick lead sheets.
1.50mm
55
The fixed/movable protective barrier shall be covered with a lead glass/acrylic viewing window with lead equivalence of at least ____mm.
1.5 mm
56