Random 2018 For captain Flashcards

1
Q

Place Aerial apparatus ——— feet from building for a good climbing angle. The —— or the ——- can assist the LCC with initial placement of the apparatus

A

25-35 feet
Officer or OV

Ladders 2 3.1.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Severe fire , people on the FE above the fire

Place the ladder alongside the FE with the tip —- away from the face of the building and about ——- above the FE railing

A

2 inches
1-3 feet

Ladders 2 3.3.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When placing an Aerial ladder to the roof, extend the ladder so that the tip is at least —— above the point where the ladder comes in contact with the building

A

At least 5 feet

Ladders 2 7.13

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The FPI ( foam plastic insulation) layer should be considered combustible since it is essentially a thermoplastic, styrofoam material, typically —— thick. The rate of heat release can be —— times higher than normal combustibles.

AUC 362

A

1/4 inch to 8 inches thick

3 to 5 times higher

Sect 1.3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

A building —- stories or higher or a large area building may require the use of a —- handline

AUC 362

A

3 stories or higher

2 1/2 inch handline

*1 3/4 handline may be sufficient for a smaller PD

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Testing at the bureau of training has shown that a —— handline equipped with the —— nozzle can be used to apply water to an exterior fire that is above the reach of ground based streams.

AUC 362

A

2 1/2

Cockloft nozzle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The —— nozzle operated upward on the exterior of the building can provide a vertical reach of —-floors. The nozzle should be extended approximately — feet from the window sill and then operated at a slight angle toward the building

AUC 362

A

Cockloft nozzle

2 floors

3 feet

Sect 3.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The Altair gas meter will alarm at :

LEL -
02-
O2-

A
  1. 0 %
  2. 5 % oxygen enriched
  3. 5 % oxygen deficient
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Altair gas sensor

A series of 3 large +++ along the screen under the O2 icon indicates the atmosphere is above —— oxygen .

EP Nat Gas Add 2

A

30 % oxygen

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When an Altair gas meter is placed out of service , the on duty officer shall call ——- and request a replacement

EP ADD 2

A

Has Mat Operations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Examples of Choking agents:

Distinctive odor:

A

Chlorine, ammonia, phosgene

Distinctive odor: chlorine, ammonia, grass

” phosgene, Phil Leto choking chicken, mows grass”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

ERP ADD 3A FDNY members shall only operate inside a Warm Zone when requested by PD. This operation must be approved by————– unless the NYPD incident commander requests entry for immediate live saving medical intervention

A

FDNY Deputy Chief

Sect 7.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Ignition temperature of CO

Haz Mat 4

A

1128 degrees F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When CO concentration falls below 100 ppm the meter will go into,law alarm. CO Meters will display readings up to ——-ppm. If readings of ——— ppm or more are detected, the CO meter will display —- indicating an over limit condition

A

999 ppm

1000 ppm

“OL”

Haz mat 4 add 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Location for the foam eductor is at the ———–

TB Foam Ev 1

A

AT THE PUMPER ONLY

This is a change !

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The member at the pumper places the pick up tube into the container and the ECC starts water, providing ——— at the eductor. The foam nozzle shall then be ——— and directed at the fire.

TB Foam

A

200 psi at the eductor

Fully opened

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

A first alarm assignment of 3 engines and 2 ladders should provide – 5 gallon containers of foam which is a total of — gallons of AR-AFFF foam concentrate. This will provide approximately—- minutes of finished firefighting foam at a 3 % setting on the eductor. At 3% the eductor will be consuming —- gallons of foam concentrate per minute.

A

13

65

17 minutes

3.75 gallons of foam concentrate per min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

The Transport Index of a package should not exceed —mr/hr

The total transport Index for a vehicles shipment should not exceed — mr/hr

ERP Add 4

A

10

50

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

The go gauge needle has two positions : GREEN and RED. The needle in the GREEN indicates proper foam proportioning, the needle in the RED indicates there is a problem such as the following:

TB FOAM ADD3

A
Kink 
Burst length
Nozzle not fully open
Nozzle shut
Elevation problem 

BENNK

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

The following units shall start each tour with at least 2 SCHOOL TRAINED CHAUFFEURS:

AUC 254

A
Satellites 
Collapse Rescue Units
Planning vehicle
Decon Units
Squads ( NEW CHANGE) 
Haz mat tech units (NEW CHANGE)

“Suffolk County PD has Squads and Haz Mat “

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

The SENSIT TKX combustible gas detector produces a “Geiger” like ticking sound which increases in frequency when a gas source as low as —— is detected

EP Gas Add 5

A

20 ppm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

When discussing back drafts at Taxpayer fires, the color of smoke varies according to the materials burning and the make-up of the flammable gases that are being produced. Dense ——–
smoke indicates the lack of oxygen and large quantities of
free carbon and carbon monoxide gas. Other colors of smoke
associated with a backdraft are —————–.

Taxpayers 4.4.1

A

Black

Dirty brown, yellow brown, and gray yellow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

While air monitoring, the Altair digital gas meter will emit a vibrating pulse and flashing green LED light every —– to alert the user the meter is operating

EP NAT GAS ADD 2

A

Every 30 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

The Search rope, when deployed , should be maintained approximately——— feet above ground

TB Rope 6 5.6

A

1-2 Feet above the ground

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Concerning the new combination metal/concrete saw blade: Diamond percentage ------ Diameter----- Arbor ----- Generates -------less sparks than abrasive blades One blade should outlast ------ quality abrasive blades TOOLS 9 DS 1 (NEW MATERIAL)
``` Diamond % 85 pct on the cutting edge 12 inch diameter 7/8 Arbor 90 pct less sparks 150 abrasive blades ``` * *** can cut wood, but not recommended * ***can be used for both wet and dry cutting
26
MOLST
Medical Orders For Life Sustaining Treatment New term 8/18, documents a patient end of life care preferences that MAY include a DNR. FOR PURPOSES OF THIS POLICY A MOLST FORM WITHOUT A DNR ORDER IS NOT SUFFICIENT FOR WITHHOLDING CPR CFR CH 2, ADD 1
27
Hospital or nursing home DNR
Review the DNR to confirm that the document : 1. Has NOT expired 2. And is from the same facility from which the patient is being transported New information 8/18 CFR CH 2 ADD 1
28
The length of the throw rope in the water SAFETY kit
75 feet of buoyant nylon rope
29
Methods and times for filling the inflatable water rescue hose
One 45 min cylinder can fill 5 lengths of 2 1/2 hose in 1 MINUTE APPARATUS AIR OUTLET can fill lengths of hose in approx 1 MINUTE new numbers 12/18, Water Rescue CH 2
30
The limit for overtime/comp time earnings
375 hours per year New number , PAID 1/2009
31
The Lobby Control Unit will the duties of the ----------- when directed by the IC ICS CH 2
Systems Control Unit
32
On Arrival, the Lobby Control Unit promptly reports to the ----------, or if not on scene, the ------ ICS CH2
Logistics Section chief IC
33
The Lobby Control Unit operates on the --------- radio channel ICS CH 2
TACTICAL
34
The operation, shutdown , or change of any building system by the Systems Control Unit, shall not be done without the permission of the IC or ------------- ICS CH 2 Add 6
Operations section chief Watch out for Logistics as a bluff answer
35
In line pumping, after the hydrant is deemed serviceable, the ----- FF Keys the hydrant Evolution 1A
The Hose FF 4 FF ENGINE : Back up 5 FF ENGINE : Door
36
Not more than --lengths of hose shall be used in the initial supply line. Generally a maximum of -- lengths of supply line may be hand stretched back to the hydrant if necessary. Evolution 1A
6 lengths 3 lengths
37
The wing cock valve on a gas meter shall be turned a 1/4 turn ---------- to shut the gas off. EP Gas
Counter clockwise Wing cock has 2 C's "counterclockwise "
38
If a water relay is necessary, the 2 hoses to use for the hydrant connection are ? Evolution 8
10 ft or 35 ft
39
The tools brought to the roof for hoisting a portable ladder to the roof ? Evolution 18
Life belt Ladder roller Utility rope FE tools " LLUF"
40
The KO curtain will ONLY be deployed on the orders of the IC, the ------------ officer will coordinate the deployment once ordered. Evolution 34
2nd due Ladder officer 2014 change
41
Discussing air pressurized standpipes, the number of air release valves is required to be such that air pressure shall be released in no more than ----------- Eng ch 9 add 2
3 minutes
42
In regard to a utility rope stretch, if the fire is below the ------ floor, then line is stretched up the stairs. Eng ch 8 8.17
Below the 3rd floor
43
Pump discharge pressure for supplying a sprinkler system should start at ......... Eng Ch 10 10.3
150 psi
44
Lithium Ion ESS, response procedures Minimum ---- radius from containers/cabinets Minimum------- from exhaust fan opening , usually on the ---- side of the FDC
50 foot 100 foot , opposite Haz Mat 19
45
When a fentanyl OD is present or suspected, and the respiratory rate is less than ----- a minute : Mucosal Atomizer Device MAD: adult ---mg -- nostril Pediatric ---mg --- nostril Narcan Nasal Spray: both Adult and Pediatric : -- mg in --nostril
Respiratory rate less than 10 a minute MAD: Adult 1 mg in EACH nostril Ped .5 mg in EACH nostril Narcan Nasal Spray Adult/Ped 4 mg in ONE nostril HAZ mat 18
46
After administration of narcan during a fentanyl overdose, If after ------- minutes minimal or no response , repeat with a second device in ------ nostril . If after ----- minutes respiratory rate isn't above ----- per min administer a repeat dose.
2-3 minutes Other nostril 5 minutes 10 breaths
47
Operations during hurricanes involve vehicles driving through standing water. The depth of water to be crossed should not exceed ---- for first line apparatus and ---- for FDNY Hi Axle units. AUC 159 p 18
18 inches 50 inches
48
The order of methods of communication for Rapid Response vehicle task forces : AUC 159 Add 8
Dars- Primary 800 MHz- Alternate Cell phones - Contingency Dept Radio - Emergency
49
Properties of Natural Gas per the New Gas bulletin: Depending on the mixture, the explosive range : Mercaptan is added as an odorant giving it a ------- smell ---------- lighter than air ---- cubic feet of NG has the approx. energy potential of --- lb(s) of TNT EP Gas 3.0
``` 5-15 % "Rotting" smell Significantly lighter than air 2 cubic feet 1 lb of TNT ``` NEW BULLETIN
50
Natural Gas Main valve covers are ------- than curb valves/service valves covers to allow servicing and my be ----- or ----- EP GAS 4.3
Larger | Round or square
51
Units shall calibrate their Flowmeters ------------ and/or when necessary to insure proper working order.
Semi -Annually TB Apparatus P2
52
Hose on apparatus is removed and clean in the ---------- of each year . Any hose that will reach ---- years during the current calendar year is to be taken out of service. Engines CH 7
Spring and Fall 10 years
53
Order for shutting down natural gas ( NEW BULLETIN)
``` Appliance Interior gas riser Meter (individual) Master meter HEAD of service valve 1. Building service valve 2. Exterior gas riser Curb valve ``` " AIM MY HEAD BEfore the CURB"
54
The letter suffix " K" designates : Comm CH 2
Division Task Force for Engines, Ladders and Battalions New information 10/18
55
When submitting a CIDS card for a non fireproof structure RENOVATED or REPAIRED using ANY type of lightweight materials would be classified as : Come CH 4
CL3LW
56
All recommendations for unit alarm assignment changes shall be submitted through the chain of command to --------- Come CH 5 5.5.3
Chief of Department In relation to the BARB program (for Captain)
57
During the start of the tour inspection of the PSS system, you depress the cam and pull -------- of rope through the EXO to ensure the device functions properly. Pull rope back through the EXO leaving --------- of rope between the EXO and the anchor hook. TB Rope 4
3-6 inches 8 inches
58
Discussing retract bollard operations , there are 2 key switches inside the control box. The ---- one is used by the FDNY for emergency use only. The ------- is for DOT use only. Tools 35
Top - FDNY bottom - DOT
59
When discussing retractable bollard operations, there is a tamper alarm on the control box. If the key is not placed in the key switch and turned within --------- after opening the control box door, the system will switch to tamper mode. Tools 35
30 seconds
60
The Floor jack: Max capacity: Lifting height : Pumps to achieve max height : Tools 37
Capacity : 2 tons ( 4000 lb) Lifting height: min 3.5 inches to max 18 inches Pumps for Max height : 5 pumps
61
Regarding the digital in line pressure gauge, an effective firefighting stream for a 2 1/2 hose line with an 1 1/8 MST is between ---------- GPM Tools 36
225-250 gpms
62
Digital in line pressure gauge: Press and hold green on/off button for -------- to turn on gauge Tools 36
4-5 seconds
63
Digital in line pressure gauge: Red digital readout flash HI-P when pressure exceeds: Blue digital readout flash HI-F when water flow exceeds : Blue digital readout flash LO-F when water flow is less than:
HI P -pressure exceeds 200 psi HI F - flow exceeds 250 gallons LO F - flow is less than 80 gpms
64
Digital in line gauge: No water flow for ------ the digital display will go into sleep mode No water flow after ------- the digital display will power off . Tools 36
15 minutes 30 minutes
65
Digital in Line gauge Fully charged battery will supply approx ------ of continuous operation . A SLOW flashing "Lo batt" indicates approx --------- of battery life remains A RAPID flashing "Lo batt" indicates approx -------- of battery life remains
5 hours 90 minutes ( 3.5 hours used) 10 minutes
66
The Blitzfire is designed for a maximum inlet pressure of ------ Tools 38
175 psi, do not exceed this pressure
67
The Blitzfire requires a minimum of ------- gpms for proper oscillating operations Tools 38
175 GPMS
68
The 1 1/4 solid stream tip on the Blitzfire will flow approximately------ gpms when supplied with 175 psi The 1 1/2 solid stream tip will flow approximately-------- gpms when supplied with 175 psi Tools 36
490 GPMS FOR 1 1/4 600 GPMS FOR 1 1/2 The 2 inch solid stream tip should NOT be used with the Blitzfire due to poor stream reach and stream break up
69
When dealing with a wind impacted fire and an alternate strategy has been successfully implemented, approval to enter the public hallway must be given by the ________________ MD's Add 3
IC, Operations, or Fire Sector Supervisor
70
Which unit upon arrival at a HRFPMD fire is responsible for Ensuring the elevators are recalled and searched ?
2nd arriving Ladder MD 6.4.2
71
In regard to Hurricane and storm preparation all members shall be reminded about "reception areas " each year on or about
May 1st AUC 159 4.2.6
72
In an underground chemical attack, which company/team is responsible for evacuation to Gross Decon ?
2nd arriving Ladder Team 1 ERP 2 6.5
73
Bowstring truss roofs may only support ______ of the load they were originally designed to hold.
40 % Taxpayers 3.3.3
74
Serious confrontations with civilians is the responsibility of ?
BITS AUC 268A1.1
75
Lobby control unit operates on the _______ channel
Tactical channel ICS Ch 2 add 4
76
When placing the Aerial ladder to a window sill, the tip of the ladder should be _________ over the window sill
Less than 6 inches Ladders 2 3.1.5
77
The TL basket can operate to reach points ______ below grade
10 Feet below grade TL pages 6-8-14
78
Units should inspect all spare cylinders (depots, Hi Rise, units, company, reserve apparatus ) for full pressure when ?
Weekly on Mondays TB SCBA 3.2.12
79
According to Chief Dunn, when is the most dangerous time for a wood floor to collapse ?
During the DECAY stage Dunn Ch 6
80
When a member assumes the "boxer" stance when cutting with the portable power saw , he should be standing with his feet _____
18-20 inches apart TB Tools 9
81
Gas alert Extreme CO meter will give a visual and low audible warning with a slow vibration if the concentration of CO exceeds _______
EXCEEDS 35 ppm, so 36 or greater * HAZ Mat 4 2.1
82
The relief valve on a TL should be set at _____
250 psi Ladders 6
83
"Danger Do Not Enter" tape is red with black lettering and is carried by __________
All Battalion and Division vehicles AUC 360 NEW
84
Charge the Post Radio ________ whether it was used or not for _________
Weekly At least 8 hours Comm Ch 12 1-2
85
After concluding TL operations, the boom should be raised to a ____ angle and the drains opened
60 degree angle Ladders 6 sec 9
86
Gravity Load is a combination of _______ and __________ load
Dead, Live Dunn
87
For communication at CFR and non fire emergencies , members can switch to which channel, when use of channel 1 is impractical?
10 New info 2017 states fire units will initiate contact using channel 1 Comm Ch 14
88
``` 10 codes for : Brush fire Outside rubbish ADV fire Smoke seeping from manhole ```
10-21 10-22 10-23 10-25-3 Com ch 8
89
FF's 6th. Grade with less than -------- of service may perform HW duty between the hours of 0900-2400. Provided they are monitored by and officer or experienced member
Less than 90 days of service Regs Ch 20
90
A defibrillator that displays a flashing black hourglass in the upper -------corner indicates ?
Right hand corner Indicates operational and ready for use CFR
91
Who is responsible for shutting down the utilities at a PD fire
2nd arriving Ladder PD Ch 4
92
Clear pale color and an odor of musky hay ?
Phosgene ERP add 2 p 20
93
During foam operations At 3%, the foam eductor will be consuming __________ of foam concentrate per minute
3.75 gallons per minute TB Foam 7.2
94
Fans blowing fresh exterior air into a structure have shown to be ______ more efficient than negative pressure ventilation.
75 % more efficient AUC 349 9.3
95
The optimum placement for the PP Fans is ________ from the attack stairway door on the ground floor with an angle tilt of ___ degrees
4-6 Feet 80 degrees AUC 349
96
Discussing negative pressure ventilation with the Dept's electric box fan, when the tarps can't be used and the fan cannot be hung, position the fan inside the contaminated area facing the exhaust opening ________ back and a tilt angle of approx._________
6-8 feet 30 degrees Watch the bluff with these numbers and the PFF fans
97
The Ultra Radiac has the capability to detect _________ types of radiation ?
Gamma and X Ray only ERP add 4 D
98
When performing an operational test of the Ultra Radiac , the following displays indicate: Blinking 9 Blinking 0
Blinking 9 indicates Utlra Radiac passed all tests Blinking 0 indicates instrument failure, place O/S ERP 4D 6.3
99
The Low Rate Alarm and High Rate Alarm for the UltraRadiac ?
Low rate alarm: 2 MR/hr High rate alarm 50R/hr ERP 4D 7.2
100
When EFAS starts, it will automatically download the latest version of the spare radio database, it will read " Radio List Updated " and the date and time in what color ?
Green letters Comm Ch 9 add3
101
FDNY members shall only operate in the Warm Zone at an active shooter incident when approved by ..........
FDNY Deputy Chief , unless the PD requests entry for immediate life saving intervention ERP add 3A
102
The Hi Rise nozzle when being supplied by a 2 1/2 hose line at 50 psi, will produce flows of --------gpms
200-225 GPMS TB Tools DS 17
103
At a chemical attack underground the unit responsible for providing the IC the number of victims
1st arriving Engine ERP add 2 sect 7
104
At a chemical attack underground , which company is responsible for site access control ?
2nd arriving Ladder team 2 ERP add 2 sect 6.6
105
During a PD cellar fire, the decision to reposition the first hose line to a secondary entrance can be made by who ?
Acting chief or Chief Officer PD Ch 3
106
Complaints shall be investigated promptly, but must be investigated within ?
24 hours after receipt BISP Ch 5
107
According to Dunn, the descending order for most likely to least likely to collapse first at Places of Worship. ?
Tower, Steeple, Chimney, Free Standing Walls The Tower and Steeple are the most unstable Dunn Ch 8
108
Fire in a LRFPMD which unit has the responsibility to ENSURE the elevators are recalled and searched ?
2nd Arriving Ladder Company MD 7.2
109
The Diamond brazed saw blade generates ------ less sparks than abrasive blades
90% less sparks Tools 9
110
During an explosive/incendiary incident, when both ladder companies are on scene, the 2nd arriving engine officer must remain at the ---------- and assume control until relieved by a Battalion chief
Triage Transfer Point ERP add 3 sect 5
111
In order to account for members eligible for Chauffeur school , Company Commanders shall forward Form CT-1 to their administrative division SEMI ANNUALLY by ?
Feb 1st and August 1st AUC 254 2.10
112
To reset an EAB, depress and hold the EAB for approximately----until the reset tone is heard
2 seconds Comm Ch 9 add 4
113
Valve colors and associated liquids on board a ship ``` Light Blue Green Yellow Red Orange ```
``` Light Blue- Fresh Water Green-Salt Water Yellow-Lube Oil Red-fuel oil Orange - Air ``` Marine manual 1.8.5
114
Units equipped with the digital in line pressure gauge should ensure batteries are rotated and recharged after use and -----
Weekly TB Tools 36
115
Correct placement of a portable ladder to a window
LEVEL with the window sill Ladders 1 7.4
116
All Ice and Cold water rescue equipment shall be inspected when ?
Quarterly, Jan, April, July , October JAJO Water Rescue 2
117
If difficulty is encountered clearing the attack stairway of occupants, the 3RD arriving ladder at a HROB fire shall advise ------------- to withhold the attack until occupants have been removed .
1st Ladder Fire Sector Supervisor or Fire Brach director HROB 8.5
118
The color of the spherical voice and flight data recorder
Bright Yellow *rectangular recorders will be red or international orange AUC 325 6.2
119
The Chief of Operations requires the supervisor of a unit to submit a "multiple member injury report" when ?
3 or more members suffer injuries at the same incident resulting in ML that TOUR SB 7 add 2
120
Even after final extinguishment seems to have been accomplished, LI-ION-ESS may re ignite ---------- after being involved in a fire.
Hours to Days HazMat 19
121
Danger Zone distances for LI-ION-ESS operations Containers/cabinets: Container/cabinet exhaust fan opening
Minimum 50 feet Minimum 100 feet HAZ Mat 19
122
POST FIRE considerations for Container/Cabinet fires involving LI-ION-ESS systems, the SME is required to be on scene within
2 Hours HAZ Mat 19
123
Pre Printed Emergency Roll Call forms can be found ??
All Battalion and Division vehicles Comm Ch 9 add 2
124
Vacant building markings should be a square approximately --- Lines of markings are to be ------ wide --------color paint
18"X 18" 2" wide Lime Yellow reflective paint Vacants 1.3
125
In EIFS, the foam plastic insulation (FPI) layer should be considered combustible and it's typically ------thick
1/4"-8" thick AUC 362
126
When used on EIFS building fires, the Cockloft nozzle can provide an upward vertical reach up to ------ floors on the exterior of the building , and should be extended approximately----- from the window sill at a slight angle toward the building.
2 floors Approximately 3 feet AUC 362
127
The isolation zone surrounding a suspicious explosive device according to the FDNY would generally exceed
300 feet ERP add 3 sect 4.1
127
Contaminated, non disposal PPE or work duty uniforms shall be placed in a double sealed clear plastic bag with a bio hazard label attached. The bag is marked correctly with
Unit assigned Name Contaminant "UNC" CFR D Ch 3
128
After discovering the apparatus Radio is defective , in order to obtain a portable citywide radio, you notify ?
Division Comm Ch 8
129
The maximum pressure to which any part of the Multi versal should be subjected to is
200 psi TB Tools 17
130
The following leaves of absence SHALL be deducted from annual leave allowance :
Emergency Leave extensions(unless reimbursement is approved and performed in 90 days ) Special Leaves with pay Leaves for legal appearances not involving city business Regs 17.1.8
131
In general, the DOT regulations require placards to be posted only on trucks that are transporting --------- pounds of a particular material
OVER 1000 pounds HAZ Mat 1
132
Commanding officers of all units shall forward reports on form BP 93 within ------- days after date veterans holiday duty was performed. The form should be filled out in -----------
4 days Triplicate Regs 17.5.6
133
When an incident is determined to to be a MAJOR GAS EMERGENCY, transmit a------- and a --------- specifying a Major Gas Emergency
10-75 and a 10-80-1 EP Gas 7.3
134
One of the conditions that is indicative of a Major Gas Emergency is elevated natural gas readings --------- LEL or greater in an unvented subsurface structure (manhole, sewer)
20 % LEL EP Gas
135
A condition indicative of a Major Gas Emergency is ------- LEL inside or outside
10 % LEL or greater EP Gas
136
A condition indicative of a Major Gas Emergency is ___________ damage to major components of the gas infrastructure (Master meter, gas service pipe, etc
SERIOUS DAMAGE Watch for word change EP Gas
137
When discussing the SENSIT TKY Gas Detector , a battery recharge takes ------- and a ------- LED will indicate a fully charged battery which will last approx__________ hours of continuous use
2-5 hours Green LED 20 hours EP Gas add
138
Con Ed main valves have ID numbers located -------- National Grid are ID'd by --------
On tags inside of the valve cover National Grid ID number stamped on the North side of the collar underneath the cover EP Gas 4.3
139
Peck vents may have a ----- cap
RED EP gas 4.4.2