Who’s brings 1st saw to cellar fire in taxpayer?
2nd due roof also throws up own portable
Who is responsible to shut down utilities at cellar/store fires?
1st due inside team
Does 1st due roof bring saw at a store / cockloft fire?
Yes 2nd due will take a second saw
1st due LCC
Taxpayer- store/cockloft fire
Join FE team, if fire extends to cockloft proceed to the roof to assist roof ff
2nd due OV
Taxpayer-store/cockloft fire
Team up with 1st due to VEIS rear
Proceed to roof or other position as directed
2nd due LCC
Taxpayer - store/cockloft fire
Position TL for most effective position
Join FE team if not directed otherwise
Where was core construction used extensively in HROB?
Buildings built after 1968
HVAC systems shall be put into non-circulating mode but?
Open all outside dampers
Closing all mixing dampers
Opening all exhaust dampers
Manuel fire pumps are required in buildings over _______ ft for 1968 building code and ______ft for 1938 building code
300ft
250ft
A loss of 25% can be expected in an _______ riser and 45% in a _________ riser
8”- eng 258
6”- eng 456
10-76 transmitted when?
Report of fire confirmed
Any stretching and operating of one hoseline will necessitate the use of “All Hands”
Transmit a 10-76 second alarm when?
Any visible fire or smoke emanation through exterior of skin of np building or when a serious fire is verified
5th Ladder at a 10-76?
FAST Unit
4th ladder at 10-76?
Operate upper floors, search of attack stairway
Not undertake roof ops until ordered by IC
Primary of top five floors
Logical assignment after roof ops would be upper floors of elevator bank serving fire floor
3rd ladder at HROB
Upon arrival at floe below fire, obtain info from 1st or 2nd due or by rapid survey of this floor
Determine number of stairs serving fire floor and floor above
Proceed to floor above fire via stairway other than attack stairway
Determine best stairway to use for evacuation and advise ICP
Remove all occupants from attack stairway for a reasonable distance above fire floor
Difficulty encountered clearing attack stairway notify 1st due ladder or fire branch director or fire sector supervisor
In HROB who selects stairway for attack of fire?
1st due ladder and stairway needs to have standpipe
Stack Effect is more noticeable in buildings over?
60ft
1st due and 2nd due LCC
TAXPAYERS - Cellar Fire
If tower ladder position in front of building
If building covers more than one street additional TL needed to cover other streets
Aerial place away from fire building
Join FE team if not directed otherwise
When is Possitive stack effect likely?
When outside air temp decreases in relation to inside air temp
Negative stack effect is greatest when?
Outside air temp is above 90 degrees
T/F 2nd due ladder at HROB can use same elevator as first due
True
What is 2nd hose line at HROB used for?
Reinforce first line
Protect position of first line
Protect search and evacuation of the fire floor
Contain and confine spread of fire or prevent fire from wrapping around the core and endangering operation of first line
In PD’s, windows with sills that are approximately chest height may require a drop of how many feet to floor level?
5-6 feet
1st hose line in PD cellar fire shall be stretched where?
Entrance that provides the quickest access to cellar in order to extinguish the fire