RMU Flashcards
(14 cards)
List what RMU supplies
RCS via Blender SF cooling BTRS RCDT PRT BA Batch Tank SAT RWST via Blender RCP #3 seals Resin sluice
Discuss what Causes RMW-V-30 to auto close
Phase A isolation (T signal)
Loss of air
Discuss design flow rate of the boric acid pumps
Each pump at 75 GPM for a total 150 GPM is equal to the design flow of one CCP
Discuss the function of the boric acid filter
removes particulates and undissolved crystals, the help prevents potential damage to the CCPs
Discuss how to borate if the Boric Acid filter was inoperable
- bypass flow around the filter (CS-V-425 or 743)
- align BAT for gravity flow to the CCP
Discuss how to Determine Boric acid injection rate
use equation:
(RCS Boron * 120GPM) / Boric Acid Tank Boron
Discuss Stepback feature
Throttles 111A or 110A in the last part of the add to prevent overshoot
State Flow deviation Alarm for Boric Acid flow
0.8 GPM for >45seconds.
VAS alarm is received and 110B/111B shuts
State Flow Deviation Alarm for Make up flow
8.0 GPM for >30 seconds
VAS alarm is received and 110B/111B shuts
Discuss flow path for Auto Make up
RMW and Boric acid pumps start
Flow goes into the bottom of the VCT (110B)
Discuss flow path for Manual Make up
RMW and Boric acid pumps are started
Flow goes into the top and Bottom of the VCT (111B and 110B)
Discuss flow path for Borate
Boric acid pump starts
Flow goes into the bottom of the VCT (110B)
Discuss flow path for Dilute and Alt Dilute
RMW pump starts
Flow goes into the top of the VCT (111B)
For alt its both (111B and 110B)
Discuss flow path for Rapid Borate
CS-V-426 opens
Boric acid pumps starts
Flow goes into the suction of the CCPs