RT - Voltage Application And Thickness Flashcards Preview

NDT Methods > RT - Voltage Application And Thickness > Flashcards

Flashcards in RT - Voltage Application And Thickness Deck (11):
1

Then sections of the most metals, moderate thicknesses of graphite and beryllium, small electronic components, wood, plastic, etc.

50 kV

2

5 inch aluminum or equivalent

150 kV none or lead foil

3

1 1/2 inch steel or equivalent

150 kV fluorescent

4

3 inch steel or equivalent

300 kV lead foil

5

4 inch steel or equivalent

300 kV fluorescent

6

3 1/2 inch steel or equivalent

400 kV lead foil

7

4 1/2 inch steel or equivalent

400 kV florescent

8

5 inch steel or equivalent

1000 kV lead foil

9

8 inch steel or equivalent

2000 kV lead foil or 1000 kV fluorescent

10

16 inch steel or equivalent

8 to 25 MeV lead foil

11

20 inch steel or equivalent

8 to 25 MeV fluorescent