SPECIFICATIONS Flashcards

(44 cards)

1
Q

UNIFORMAT LEVEL 1

A
A / SUBSTRUCTURE
B / SHELL
C / INTERIORS
D / SERVICES
E / EQUIPMENT and FURNISHINGS
F / SPECIALTIES and DEMO
G / SITEWORK
Z / GENERAL
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

UNIFORMAT MAJOR GROUP ELEMENTS

A

A

A / SUBSTRUCTURE

A10 - Foundation
A20 - Basement Conditions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

UNIFORMAT MAJOR GROUP ELEMENTS

B

A

B / SHELL

B10 - Superstructure
B20 - Exterior Enclosure
B30 - Roofing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

UNIFORMAT MAJOR GROUP ELEMENTS

C

A

C / INTERIORS

C10 - Interior Construction
C20 - Stairs
C30 - Interior Finishes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

UNIFORMAT MAJOR GORUP ELEMENTS

D

A

D / SERVICES

D10 - Conveying
D20 - Plumbing
D30 - HVAC
D40 - Fire Protection
D50 - Electrical
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

UNIFORMAT MAJOR GROUP ELEMENTS

E

A

E / EQUIPMENT and FURNISHINGS

E10 - Equipment
E20 - Furnishings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

UNIFORMAT MAJOR GROUP ELEMENTS

F

A

F / SPECIAL CONSTRUCTION & DEMO

F10 - Special Construction
F20 - Demolition

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

UNIFORMAT MAJOR GROUP ELEMENTS

G

A

G / BUILDING SITEWORK

G10 - Site Preparation
G20 - Site Improvements
G30 - Site Civil/Mechanical Utilities
G40 - Site Electrical Utilities
G90 - Other Site Construction
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

MASTER FORMAT MAJOR GROUPS

A
  • PROCUREMENT & CONTRACTING REQUIREMENTS
  • –[00]
  • SPECIFICATION GROUP
  • –General Requirements [01]

TECHNICAL SPECIFICATIONS:

  • –Facility Construction Group [02-14]
  • –Facility Services Group [21-28]
  • –Site Infrastructure [31-35]
  • –Process Equipment [40-48]
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

MASTER FORMAT Sub-Group

Facility CONSTRUCTION

A

[02-14]

02 - Existing Conditions
03 - Concrete
04 - Masonry
05 - Metals
06 - Wood, Plastics, Composites
07 - Thermal and Moisture Protection
08 - Openings
09 - Finishes
10 - Specialties
11 - Equipment
12 - Furnishings
13 - Special Construction
14 - Conveying Equipment
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

MASTER FORMAT Sub-Group

Facility SERVICES

A

[21-28]

21 - Fire Suppression
22 - Plumbing
23 - HVAC
24 - OPEN
25 - Integrated Automation
26 - Electrical
27 - Communications
28 - Electronic Safety and Security
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

MASTER FORMAT Sub-Group

SITE and INFRASTRUCTURE

A

[31-35]

31 - Earthwork
32 - Exterior Improvements
33 - Utilities
34 - Transportation
35 - Waterway and Marine Construction
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

MASTER FORMAT Sub-Group

PROCESS EQUIPMENT

A

[40-48]

40 - Process Interconnections
41 - Material Processing and Handling Equipment
42 - Process Heating, Cooling, and Drying Equipment
43 - Process Gas and Liquid Handling, Purification and Storage Equipment
44 - Pollution and Waste Control Equipment
45 - Industry-Specific Manuf Equipment
46 - Water and Wastewater Equip.
47 - OPEN
48 - Electrical Power Generation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

MASTER FORMAT Sub-Group

PROCESS EQUIPMENT

A

[40-48]

40 - Process Interconnections
41 - Material Processing and Handling Equip.
42 - Process Heating, Cooling, and Drying Equip.
43 - Process Gas and Liquid Handling, Purif. and Storage Equip.
44 - Pollution and Waste Control Equip.
45 - Industry-Specific Manuf Equip.
46 - Water and Wastewater Equip.
47 - OPEN
48 - Electrical Power Generation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

MASTER FORMAT Sub-Group

FACILITY CONSTRUCTION

DIVISIONS 10 - 14

A
10 - SPECIALTIES
11 - EQUIPMENT
12 - FURNISHINGS
13 - SPECIAL CONSTRUCTION
14 - CONVEYING EQUIPMENT
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

MASTER FORMAT DIVISIONS

SPECIALTIES

A

DIVISION 10, SPECIALTIES

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

MASTER FORMAT

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

//PROCUREMENT REQUIREMENTS//

A

DIVISION 00 - Procurement & Contracting Req.
Procurement Req. 00 10 00 - 00 40 00

00 10 00 Solicitation
00 20 00 Instructions for Procurement
00 30 00 Available Information
00 40 00 Procurement Forms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

MASTER FORMAT

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

//CONTRACTING REQUIREMENTS//

A

DIVISION 00 - Procurement & Contracting Req.
Contracting Req. 00 50 00 - 00 90 00

00 50 00 Contracting Forms and Supplements
00 60 00 Project Forms
00 70 00 Conditions of the Contract
00 80 00 Unassigned
00 90 00 Revisions, Clarifications, and Modifications

19
Q

MASTER FORMAT

DIVISION 01 - GENERAL REQUIREMENTS

A

DIVISION 01 - General Requirements

01 10 00 Summary
01 20 00 Price and Payment Procedure
01 30 00 Administrative Req.
01 04 00 Quality Req.
01 05 00 Temporary Facilities Controls
01 06 00 Product Requirements
01 07 00 Execution and Closeout Req.
01 08 00 Performance Req.

01 09 00 Life Cycle Activities
Commissioning, Facility Operation, Maintenance, Decommissioning

20
Q

MASTER FORMAT

00 40 00

A

00 40 00 PROCUREMENT FORMS and SUPPLEMENTS

00 41 00 Bid Forms
00 42 00 Proposal Forms
00 43 00 Procurement Form Supplements
00 45 00 Representations and Certifications

21
Q

MASTER FORMAT

00 70 00

A

00 70 00 CONDITIONS of the CONTRACT

00 71 00 Contracting Definitions
00 72 00 General Conditions
00 73 00 Supplementary Conditions

22
Q

MASTER FORMAT

00 60 00

A

00 60 00 PROJECT FORMS

00 61 00 Bond Forms
00 62 00 Certificates and Other Forms
00 63 00 Clarification and Modification Forms
00 65 00 Closeout Forms

23
Q

MASTER FORMAT

01 90 00

A

01 90 00 LIFE CYCLE ACTIVITIES

01 91 00 Commissioning
01 92 00 Facility Operation
01 93 00 Facility Maintenance
01 94 00 Facility Decommissioning

24
Q

MASTER FORMAT

DIVISION 05

A

DIVISION 05 - METALS

05 10 00 - Structural Metal Framing
05 20 00 - Metal Joists
05 30 00 - Metal Decking

05 40 00 - Cold-Formed Metal Framing
05 50 00 - Metal Fabrications: stairs, railings, gratings, metal specialties
05 60 00 - Decorative Metal

25
MASTER FORMAT DIVISION 10
DIVISION 10 - SPECIALTIES 10 10 00 - Information Specialties: visual display, signage. directories 10 20 00 - Interior Specialties: compartments and cubicles, partitions, service walls, toilet and bath accessories 10 30 00 - Fireplaces and Stoves: manuf fireplaces, fireplace specialties, stoves 10 40 00 - Safet Specialties: emergency access info cabinets, emergency aid specialties, fire protection specialties 10 50 00 - Storage Specialties: lockers, postal specialties, storage assemblies, wardrobe and closet specialties, 10 70 00 - Exterior Specialties: exterior protection protective covers, manuf ext specialties, flagpoles 10 80 00 - Other Specialties: pest control devices, grilles and screens, flags and banners, gas lighting, security mirrors and domes, scales
26
MASTER FORMAT DIVISION 12
DIVISION 12 - FURNISHINGS 12 10 00 - Art: murals, sculptures, religious art 12 20 00 - Window Treatments: window blinds, curtains and drapes, shutters 12 30 00 - Casework: manuf mtl casework, manuf wood casework, manuf plastic casework, specialty casework, countertops 12 40 00 - Furnishings and Accessories: office accessories, table accessories, portable lamps, bath and bedroom furnishings, rugs and mats 12 50 00 - Furniture: office, retail, hospitality etc furn 12 60 00 - Multiple Seating: fixed audience seating, booths and tables, pews and benches
27
MASTER FORMAT DIVISION 13
DIVISION 13 - SPECIAL CONSTRUCTION 13 10 00 - Special Facility Components: pools, fountains, aquariums, ice rinks, animal shelters, SAUNAS 13 20 00 - Special Purpose Rooms: office shelters and booths, planetariums, vaults, athletic and rec special construction 13 30 00 - Special Structures: fabric structures, space frames, geodesic domes, rammed earth construction, towers 13 40 00 - Integrated Construction: bldg modules and components, modular mezzanines sound vibration control, radiation protection 13 50 00 - Special Instrumentation: stress instrumentation, sismic instrumentation, meteorological instrumentation
28
MASTER FORMAT DIVISION 14
DIVISION 14 - CONVEYING EQUIPMENT 14 10 00 - Dumbwaiters 14 20 00 - Elevators 14 30 00 - Escalators and Moving Walks 14 40 00 - Lifts: wheelchair lifts, vehicle lifts 14 70 00 - Turntables 14 80 00 - Scaffolding 14 90 00 - Other Conveying Equip: trash chutes
29
MASTER FORMAT DIVISION 11
DIVISION 11 - EQUIPMENT 11 10 00 - Vehicle and Pedestrian Equip. 11 20 00 - Commercial Equip. 11 30 00 - Residential Equip. 11 40 00 - Foodservice Equip.: food prep equip, food delivery carts and conveyors, food cooking equip. 11 50 00 - Educational and Scientific Equip. 11 60 00 - Entertainment and Rec Equip. 11 70 00 Healthcare Equip.: medical sterilizing equip., mortuary equip., radiology equip., operating room equip. 11 80 00 - Facility Maintenance and Operation Equipment
30
MASTER FORMAT DIVISION 21
DIVISION 21 - FIRE SUPPRESSION 21 10 00 - Water-Based Fire-Suppression Systems 21 20 00 - Fire-Extinguishing Systems 21 30 00 - Fire Pumps 21 40 00 - Fire-Suppression Water Storage
31
MASTER FORMAT DIVISION 22
DIVISION 22 - PLUMBING 22 10 00 - Piping 22 30 00 - Plumbing Equip. 22 40 00 - Plumbing Fixtures 22 50 00 - Pool and Fountain Plumbing Systems 22 60 00 - Gas and Vacuum Systems for Laboratory and Healthcare Facilities
32
MASTER FORMAT DIVISION 23
DIVISION 23 - HVAC ``` 23 10 00 - Facility Fuel Systems 23 20 00 - HVAC Piping and Pumps 23 30 00 - HVAC Air Distribution 23 40 00 - HVAC Cleaning Devices: particulate air filtration 23 50 00 - Central Heating Equip. 23 60 00 - Central Cooling Equip. 23 70 00 - Central HVAC Equip. 23 80 00 - Decentralized HVAC Equip.: convection heating and cooling units, radiant heating and cooling units, humidity control equip. ```
33
MASTERFORMAT DIVISION 26
DIVISION 26 - ELECTRICAL 26 10 00 - Medium Voltage Electrical Distribution 26 20 00 - Low Voltage Electrical Distribution 26 30 00 - Facility Electrical Power Generating and Storing Equip. 26 40 00 - Electrical Protection: surge protective devices 26 50 00 - Lighting: interior, safety, classified location, special purpose, exterior
34
MASTER FORMAT 26 50 00
26 50 00 - LIGHTING ``` 26 51 00 - Interior Lighting 26 52 00 - Safety Lighting 26 54 00 - Classified Location Lighting 26 55 00 - Special Purpose Lighting 26 56 00 - Exterior Lighting ```
35
MASTER FORMAT DIVISION 27
DIVISION 27 - COMMUNICATIONS ``` 27 10 00 - Structured Cabling 27 20 00 - Data Comms 27 30 00 - Voice Comms 27 40 00 - Audio-Video Comms 27 50 00 - Distributed Comms and Monitoring Systems ```
36
MASTER FORMAT DIVISION 28
DIVISION 28 - ELECTRONIC SAFETY AND SECURITY 28 10 00 - Access Control: access control hardware, devices, interfaces 28 20 00 - Video Surveilance 28 30 00 - Security Detection, Alarm, and Monitoring 28 40 00 - Life Safety: radiation detection alarm, gas detection alarm, emergency response systems 28 50 00 - Specialized Systems
37
SECTION FORMAT
PART 1 GENERAL: describes administrative, procedural, and temporary requirements unique to the section. PART 2 PRODUCTS: describes products, materials, equipment, fabrications, mixes, systems, and assemblies, that are required PART 3 EXECUTION: describes installation or application, including preparatory actions and post-installation cleaning and protection.
38
THE 4 METHODS OF SPECIFYING
1. DESCRIPTIVE 2. PERFORMANCE 3. REFERENCE STANDARD 4. PROPRIETARY
39
DESCRIPTIVE SPECIFICATION
Specifies properties of materials and methods of installation w/o using proprietary names. A detailed description of physical properties, and workmanship req. for the installation of a product or material. Req. TECHNICAL KNOWLEDGE and experience The burden of performance is assumed by A/E when a descriptive spec is used Lengthy and tedious - not used as often when proprietary names are prohibited by law and when adequate reference standards do no exist, a descriptive spec may be only logical choice.
40
PERFORMANCE SPECIFICATION
The end result instead of the means to the end result is specified - must include a way of verifying compliance through some measurement, test, evaluation, or other assurances. a clg hangar described as "nonsag" (performance) vs "straightened no. 11 wire, tightly wrapped two times" (descriptive) The contractor is free to choose materials and methods complying with Performance criteria. A description of the end result of a product or system and includes criteria to be used for verification of proper installation. Used to encourage INNOVATIVE TECHNIQUES - DELEGATES DESIGN TO INDUSTRY SPECIALISTS
41
REFERENCE SPECIFICATION
Specifies products or processes by established standards. uses recognized industry standards rather than individually written product or installation criteria standards must be reviewed carefully to avoid duplications, optional requirements, and contradictions SAVES A/E TIME example: ASTM B 211, standard spec for aluminum and aluminum alloy extruded bars, rods, wires, shapes, tubes, ANSI safety codes Reference standards might contain embedded options, are typ minimums
42
PROPRIETARY SPECIFICATION
Specifies actual brand names, model numbers, and other proprietary information. describes products and materials by manufacturer's name, brand name, model number, or unique characteristic. CLOSED PROPRIETARY specs do not allow for substitutions OPEN PROPRIETARY specs allow for alternative products If no proprietary name is used and only one company supplies the item then it is considered a proprietary spec
43
WHEN TO USE REFERENCE SPEC
1. KNOW THE STANDARD: free of duplications, conflicts - could state most stringent is used, some standards have diff classes of option (A/E must specify which class) 2. INCORPORATE THE STANDARD PROPERLY 3. ENFORCE THE REQUIREMENTS OF THE STANDARD
44
PROPERLY INCORPORATING REFERENCE SPEC
1. Name of issuing organization 2. Number of the standard 3. Title of the standard 4. Date of issue of the standard 5. Citation of applicable requirements unless entire standard is applicable