Standards & Topics Flashcards

(68 cards)

1
Q

ASTM E 2128

A

ASTM Standard Guide for Evaluating Water Leakage of Building Walls

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

ASTM E 1105

A

ASTM
Standard Test Method for Field Determination of Water Penetration of Installed Ext. Windows, Skylights, Doors and Curtain Walls (by uniform or cyclical Air Pressure Difference).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

ASTM E 1105 Procedure A

A

Fenestration testing for a single, 15 minute cycle.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

ASTM E 1105 Procedure B

A

Fenestration testing using a minimum of 3, 5-minute pressure cycles* with 1 minute rest between.

*or equivalent, 15 min. Minimum.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Minimum time of pressure application required by ASTM E 1105, Procedure B

A

15 minutes (3 cycles at 5 min).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What ASTM Standard is referenced by AAMA 907 for coating adhesion.

A

ASTM B571 - Standard Practice for Qualitative Adhesion Testing of metallic Coatings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What ASTM standard is used to evaluate adhesion of non metallic coatings, referenced by AAMA 907

A

ASTM D3359. Standard Test Method for Rating Adhesion by Tape Test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the process used for evaluating hardware corrosion resistance per AAMA 907 - ASTM B117

A

Parts are immersed in a salt-spray fog test for 300 hours.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the threshold for passing the ASTM B117 Corrosion resistance test?

A

No more than location per square inch of loss of adhesion, corrosion or blistering, or any spots larger than 1/16”.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

ASTM Standard Method for Determining Rate of Air Leakage Through Exterior Windows, Doors…. etc. (Laboratory Test).

A

ASTM E283

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

ASTM Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference
(Laboratory Test)

A

ASTM E331

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

ASTM Standard Practice for Operating Fluorescent Ultraviolet UV lamp apparatus for exposure of nonmentallic materials.

A

ASTM G154

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

ASTM Standard for testing polymer Shore A or Shore B hardness using a durometer

A

ASTM C661

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

ASTM Standard for lap-shear test cited by AAMA 800

A

ASTM C961.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

ASTM standard defining sealant ‘Slump’ or tape ‘sag’ as referenced in AAMA 800:

A

ASTM D2202

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

ASTM Standard pertaining to sealant ‘vehicle migration’ referenced in AAMA 800:

A

ASTM D2203

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

ASTM Standard cited by AAMA 800 for evaluation of low-temperature flexibility in sealant:

A

ASTM C734

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

ASTM C734 calls for heating the subject to what temperature and for what duration? This is followed by cooling to what temperature, for how long, prior to bending and inspection?

A

180 degrees for 14 days

7 degrees for 24 hours.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What criteria are used for visual screening of BBMTGT per AAMA 800.

A

No surface cracks or bond loss in any sample.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Standard test method for oil migration or plasticizer bleed-out of preformed tape sealants

A

ASTM C772

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Standard test method for adhesion in Peel of Elastomeric Joint Sealants

A

ASTM C794

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Standard Test Method for Tensile Adhesive Strength of Preformed Tape Sealants by Disk method

A

ASTM C907

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Standard Test method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Cyclic Static Air Pressure Difference.

A

ASTM E547

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference.

A

ASTM E531

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Standard Test method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference.
ASTM E330
26
Standard Practice for Determining Load Resistance of Glass in Buildings.
ASTM E1300
27
The air pressure difference applied to windows per ASTM E547 and E331 is equal to what percent of the design pressure? How i this different for AW (Architectural) windows?
15% for most windows | 20% for AW windows.
28
ASTM E1300 makes what assumptions regarding stiffness of the support system?
The glass edge support system limits deflection to less than 1/175 of the length of the panel at a given load.
29
Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
ASTM E1886
30
Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes
ASTM E1996 This specification provides the information required to conduct Test Method E1886.
31
Summarize the test process or standards established in ASTM E1886.
Test specimen is subjected to a specified missile impact, followed by a number of cycles of positive and negative static pressure differential.
32
Standard Specification for Window Fall Prevention Devices With Emergency Escape (Egress) Release Mechanisms
ASTM F2090
33
Standard for Fire Doors and Other Opening Protectives
NFPA 80
34
This standard establishes the specifications and methods of testing for the safety properties of safety glazing materials as used for all building and architectural purposes.
ANSI Z97.1
35
Prescribes the mandatory safety requirements for glazing materials used or intended for use in any of the following architectural products: (1) Storm doors or combination doors. (2) Doors. (3) Bathtub doors and enclosures. (4) Shower doors and enclosures. (5) [Reserved] (6) Sliding glass doors (patio-type).
CPSC 16 CFR 1201
36
Specification for Operating Cycle Performance of Side-Hinged Exterior Door Systems
AAMA 920
37
Voluntary Specification for Determining Forced Entry Resistance of Side-Hinged Door Systems
AAMA 1304
38
Voluntary Specification for the Water Penetration Resistance and Structural Load Performance of Locking/Latching Hardware Used in Side-Hinged Door Systems
AAMA 930
39
Specification for Determining the Vertical Loading Resistance of Side-Hinged Door Leaves
AAMA 925
40
Energy Standard for Buildings Except Low-Rise Residential Buildings.
ASHRAE 90.1
41
Standard Specification for Insulating Glass Unit Performance and Evaluation
ASTM E2190
42
Procedure for Determining Fenestration Product U-Factors
ANSI/NFRC 100:
43
Determining Fenestration Product Solar Heat Gain Coefficient
ANSI/NFRC 200:
44
Procedure for Determining Fenestration Product Air Leakage
ANSI/NFRC 400
45
Voluntary Installation Guidelines for Unit Skylights.
AAMA 1607
46
Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics
ASTM D1003
47
Standard Practice for Goniometric Optical Scatter Measurements (Use for haze factor >30% per D1003)
ASTM E2387
48
Test Method for Water Resistance: Hydrostatic Pressure | Used in determining water-resistance of paper flashings
AATCC 127
49
Voluntary Specification for Mechanically Attached Flexible Flashing
AAMA 712
50
Voluntary Specification for Self Adhering Flashing Used for Installation of Exterior Wall Fenestration Products
AAMA 711
51
Voluntary Test Method to Determine Chemical Compatibility of Sealants and Self-Adhered Flexible Flashings
AAMA 713
52
Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection
ASTM D1970
53
Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension Referenced by AAMA 711 for SAF tensile strength
ASTM D412
54
Standard Test Method for Low-Temperature Flexibility of Preformed Tape Sealants
ASTM C765
55
Standard Test Method for Peel Adhesion of Pressure-Sensitive Tape
ASTM D3330
56
Standard Practice for the Installation of Windows with Frontal Flanges for Surface Barrier Masonry Construction for Extreme Wind/Water Conditions
FMA / AAMA 200
57
Voluntary Specification for Liquid Applied Flashing Used to Create a Water-Resistive Seal around Exterior Wall Openings in Buildings
AAMA 714
58
Standard Test Method for Adhesion-in-Peel of Elastomeric Joint Sealants (Referenced by AAMA 714 for FAF adhesion testing)
ASTM C794
59
Standard Test Method for Crack Bridging Ability of Liquid-Applied Waterproofing Membrane. (Referenced by AAMA 714 for crack bridging at low temperature)
ASTM C1305
60
Standard specification for Elastomeric Joint Sealants
ASTM C920
61
Standard Test Method for Determining Tensile Adhesion Properties of Structural Sealants (For glass/metal sealant adhesion testing.)
ASTM C1135
62
What standard provides a means of testing sealant compatibility with glazing accessories?
ASTM C1087
63
Standard Test Method for Staining of Porous Substrate by Joint Sealants
ASTM C1248
64
Standard Practice for Installation of Exterior Windows, Doors and Skylights.
ASTM E2112
65
Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference (Lab)
ASTM E547
66
Standard Guide for Evaluating Water Leakage of Building Walls
ASTM E2128
67
The key difference between ASTM E283 and ASTM E783 is:
I know you think you know this, but double check - is it really just field vs. lab?
68
Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors,and Curtain Walls by Cyclic Static Air Pressure Difference
ASTM E547