Standards & Topics Flashcards

1
Q

ASTM E 2128

A

ASTM Standard Guide for Evaluating Water Leakage of Building Walls

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

ASTM E 1105

A

ASTM
Standard Test Method for Field Determination of Water Penetration of Installed Ext. Windows, Skylights, Doors and Curtain Walls (by uniform or cyclical Air Pressure Difference).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

ASTM E 1105 Procedure A

A

Fenestration testing for a single, 15 minute cycle.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

ASTM E 1105 Procedure B

A

Fenestration testing using a minimum of 3, 5-minute pressure cycles* with 1 minute rest between.

*or equivalent, 15 min. Minimum.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Minimum time of pressure application required by ASTM E 1105, Procedure B

A

15 minutes (3 cycles at 5 min).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What ASTM Standard is referenced by AAMA 907 for coating adhesion.

A

ASTM B571 - Standard Practice for Qualitative Adhesion Testing of metallic Coatings

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What ASTM standard is used to evaluate adhesion of non metallic coatings, referenced by AAMA 907

A

ASTM D3359. Standard Test Method for Rating Adhesion by Tape Test

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the process used for evaluating hardware corrosion resistance per AAMA 907 - ASTM B117

A

Parts are immersed in a salt-spray fog test for 300 hours.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the threshold for passing the ASTM B117 Corrosion resistance test?

A

No more than location per square inch of loss of adhesion, corrosion or blistering, or any spots larger than 1/16”.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

ASTM Standard Method for Determining Rate of Air Leakage Through Exterior Windows, Doors…. etc. (Laboratory Test).

A

ASTM E283

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

ASTM Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference
(Laboratory Test)

A

ASTM E331

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

ASTM Standard Practice for Operating Fluorescent Ultraviolet UV lamp apparatus for exposure of nonmentallic materials.

A

ASTM G154

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

ASTM Standard for testing polymer Shore A or Shore B hardness using a durometer

A

ASTM C661

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

ASTM Standard for lap-shear test cited by AAMA 800

A

ASTM C961.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

ASTM standard defining sealant ‘Slump’ or tape ‘sag’ as referenced in AAMA 800:

A

ASTM D2202

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

ASTM Standard pertaining to sealant ‘vehicle migration’ referenced in AAMA 800:

A

ASTM D2203

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

ASTM Standard cited by AAMA 800 for evaluation of low-temperature flexibility in sealant:

A

ASTM C734

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

ASTM C734 calls for heating the subject to what temperature and for what duration? This is followed by cooling to what temperature, for how long, prior to bending and inspection?

A

180 degrees for 14 days

7 degrees for 24 hours.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What criteria are used for visual screening of BBMTGT per AAMA 800.

A

No surface cracks or bond loss in any sample.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Standard test method for oil migration or plasticizer bleed-out of preformed tape sealants

A

ASTM C772

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Standard test method for adhesion in Peel of Elastomeric Joint Sealants

A

ASTM C794

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Standard Test Method for Tensile Adhesive Strength of Preformed Tape Sealants by Disk method

A

ASTM C907

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Standard Test method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Cyclic Static Air Pressure Difference.

A

ASTM E547

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference.

A

ASTM E531

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

Standard Test method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference.

A

ASTM E330

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

Standard Practice for Determining Load Resistance of Glass in Buildings.

A

ASTM E1300

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

The air pressure difference applied to windows per ASTM E547 and E331 is equal to what percent of the design pressure?
How i this different for AW (Architectural) windows?

A

15% for most windows

20% for AW windows.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

ASTM E1300 makes what assumptions regarding stiffness of the support system?

A

The glass edge support system limits deflection to less than 1/175 of the length of the panel at a given load.

29
Q

Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials

A

ASTM E1886

30
Q

Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes

A

ASTM E1996

This specification provides the information required to conduct Test Method E1886.

31
Q

Summarize the test process or standards established in ASTM E1886.

A

Test specimen is subjected to a specified missile impact, followed by a number of cycles of positive and negative static pressure differential.

32
Q

Standard Specification for Window Fall Prevention Devices With Emergency Escape (Egress) Release Mechanisms

A

ASTM F2090

33
Q

Standard for Fire Doors and Other Opening Protectives

A

NFPA 80

34
Q

This standard establishes the specifications and methods of testing for the safety properties of safety glazing materials as used for all building and architectural purposes.

A

ANSI Z97.1

35
Q

Prescribes the mandatory safety requirements for glazing materials used or intended for use in any of the following architectural products:

(1) Storm doors or combination doors.
(2) Doors.
(3) Bathtub doors and enclosures.
(4) Shower doors and enclosures.
(5) [Reserved]
(6) Sliding glass doors (patio-type).

A

CPSC 16 CFR 1201

36
Q

Specification for Operating Cycle Performance of Side-Hinged Exterior Door Systems

A

AAMA 920

37
Q

Voluntary Specification for Determining Forced Entry Resistance of Side-Hinged Door Systems

A

AAMA 1304

38
Q

Voluntary Specification for the Water Penetration Resistance and Structural Load Performance of Locking/Latching Hardware Used in Side-Hinged Door Systems

A

AAMA 930

39
Q

Specification for Determining the Vertical Loading Resistance of Side-Hinged Door Leaves

A

AAMA 925

40
Q

Energy Standard for Buildings Except Low-Rise Residential Buildings.

A

ASHRAE 90.1

41
Q

Standard Specification for Insulating Glass Unit Performance and Evaluation

A

ASTM E2190

42
Q

Procedure for Determining Fenestration Product U-Factors

A

ANSI/NFRC 100:

43
Q

Determining Fenestration Product Solar Heat Gain Coefficient

A

ANSI/NFRC 200:

44
Q

Procedure for Determining Fenestration Product Air Leakage

A

ANSI/NFRC 400

45
Q

Voluntary Installation Guidelines for Unit Skylights.

A

AAMA 1607

46
Q

Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics

A

ASTM D1003

47
Q

Standard Practice for Goniometric Optical Scatter Measurements (Use for haze factor >30% per D1003)

A

ASTM E2387

48
Q

Test Method for Water Resistance: Hydrostatic Pressure

Used in determining water-resistance of paper flashings

A

AATCC 127

49
Q

Voluntary Specification for Mechanically Attached Flexible Flashing

A

AAMA 712

50
Q

Voluntary Specification for Self Adhering Flashing Used for Installation of Exterior Wall Fenestration Products

A

AAMA 711

51
Q

Voluntary Test Method to Determine Chemical Compatibility of Sealants and Self-Adhered Flexible Flashings

A

AAMA 713

52
Q

Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection

A

ASTM D1970

53
Q

Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension

Referenced by AAMA 711 for SAF tensile strength

A

ASTM D412

54
Q

Standard Test Method for Low-Temperature Flexibility of Preformed Tape Sealants

A

ASTM C765

55
Q

Standard Test Method for Peel Adhesion of Pressure-Sensitive Tape

A

ASTM D3330

56
Q

Standard Practice for the Installation of Windows with Frontal Flanges for Surface Barrier Masonry Construction for Extreme Wind/Water Conditions

A

FMA / AAMA 200

57
Q

Voluntary Specification for Liquid Applied Flashing Used to Create a Water-Resistive Seal around Exterior Wall Openings in Buildings

A

AAMA 714

58
Q

Standard Test Method for Adhesion-in-Peel of Elastomeric Joint Sealants
(Referenced by AAMA 714 for FAF adhesion testing)

A

ASTM C794

59
Q

Standard Test Method for Crack Bridging Ability of Liquid-Applied Waterproofing Membrane.

(Referenced by AAMA 714 for crack bridging at low temperature)

A

ASTM C1305

60
Q

Standard specification for Elastomeric Joint Sealants

A

ASTM C920

61
Q

Standard Test Method for Determining Tensile Adhesion Properties of Structural Sealants
(For glass/metal sealant adhesion testing.)

A

ASTM C1135

62
Q

What standard provides a means of testing sealant compatibility with glazing accessories?

A

ASTM C1087

63
Q

Standard Test Method for Staining of Porous Substrate by Joint Sealants

A

ASTM C1248

64
Q

Standard Practice for Installation of Exterior Windows, Doors and Skylights.

A

ASTM E2112

65
Q

Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference (Lab)

A

ASTM E547

66
Q

Standard Guide for Evaluating Water Leakage of Building Walls

A

ASTM E2128

67
Q

The key difference between ASTM E283 and ASTM E783 is:

A

I know you think you know this, but double check - is it really just field vs. lab?

68
Q

Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors,and Curtain Walls by Cyclic Static Air Pressure Difference

A

ASTM E547