Storage week 2 Flashcards
(26 cards)
Who is resposible for over all fire for a site??
Everyone has a responsibility but overaching it all sits under the CO
what must an emergancy water supply be within?
With reasonable distance of storage facility
What are the two types of fire fightingmeasures?
First aid firing fighting -
Major fire fighting measures
When does a electrical fire alarm system need to be tested?
Weekly, and 6 monthly for mechanincal
What must be avalible for natural EWS supplies?
An access road that can take a fire truck
Man made EWS must be?
2 static tanks within 100m
what are the vegiation rules?
No veg in one meter
kept cm - to 6 m after
beyound 6m locallly accpet risk
ever greens 30m away
other types 15m treess
When is a munition unsafe?
When it doesnt meet the safe critria, or when the condition is unknown
What is isolated storage?
The storage of expllsoives in an unsafe or psosibly unsafe conditoin in spearate licensed accommodation away from all other explosives
What is unsafe repairable?
an example is need fuze replacing
wat is salavaged stores?
After an accident explosion fire or trail needs isolation
What cant you do with 1.1?
It needs isloating completely when unsafe
Can you mix service life stock with end of service life stock?
no
What should you do between stocks
make sure there is a physical barrier
What is the difference between segrgation and isolation?
Segragated can be stored in the house but with a physical barrier, isolated is in different buildings
Whats the definition of stock muntion conditioncodeS?
A! - no limitations
A2 - a sort of constraint but can be used
A3 - proect team must allow to use
A4 - limitation on flying hourse
B must be not mixed
B1 - banned for use
B2 - banned for issue or use ( maybe incident with transport)
B3 - awaiting quality assurance
B4 - SLED
C1- minor procesing required
C2 - major mod processing required
C3 - been on excerise and needs inspecting to go back out
C4 - Civvy company needs to look at i t
C5 - large scale repair needs to be done
D1- surplus to requrement
D2 - Unservicable disposal (would cost more to repair then just disposal and replace)
D3 - send back to manufacture to do what ever they like
What can DU not be stored with ?
1.1-1.2-1.3( if possible)
What are the rules for DU?
no more the t ULS high, OQD min 500m evacuated upwind. IBD distance is 1.33 no one in 500m 22.5degress away from front of building
Guided weapons must be pointed where?
In a safe direction, most likely towards a wall
What must you do for experimental explosives?
segregated, sponsor provides disposal, contact sponsor every 6 months, packed and conetents are to be marked
Be careful with big munitions which take up more than one unit of space
Where to find space requirements
DSA 03.ome PT 2 chap 13 annex B para 1.2
Whats the difference between service life and safe life?
Service/op life is when its open, and safe is manufactured
Planning consideration for ammo
HCC, NEQ, 2 point dsiperal, ADC, clearnce from walls and door, ops/trg, speical sotrage required, qty, nature