Test 3 Flashcards

(40 cards)

1
Q

THE PRIMARY CONCERN OF THE WATER PURVEYOR WHERE AN AUXILIARY WATER SYSTEM IS MAINTAINED AND UTILIZED BY A CUSTOMER, IS TO ASSURE THAT __________.
A. THE AUXILIARY SYSTEM PRESSURE IS LESS THAN THE PUBLIC WATER SYSTEM PRESSURE.
B. AN APPROVED BACKFLOW PREVENTION ASSEMBLY IS INSTALLED ON THE SERVICE CONNECTION.
C. THE AUXILIARY SYSTEM IS CHLORINATED
D. THE AUXILIARY WATER SYSTEM IS METERED

A

B. AN APPROVED BACKFLOW PREVENTION ASSEMBLY IS INSTALLED ON THE SERVICE CONNECTION.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

ATMOSPHERIC TYPE VACUUM BREAKERS SHALL NOT BE SUBJECTED TO CONTINUOUS WATER PRESSURE FOR PERIODS THAT LAST LONGER THAN _______.
A. 6 HOURS
B. 12 HOURS
C. 18 HOURS
D. 24 HOURS

A

B. 12 HOURS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

WHAT CAUSES THE RELIEF VALVE TO CLOSE ON A REDUCED PRESSURE PRINCIPLE ASSEMBLY?
A. RELIEFT VALVE SPRING PRESSURE
B. SUPPLY SIDE WATER PRESSURE
C. PRESSURE DIFFERENTIAL BETWEEN CHECK VALVE #1 AND CHECK VALVE #2
D. ALL OF THE ABOVE

A

B. SUPPLY SIDE WATER PRESSURE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

WHICH OF THE FOLLOWING CAN CAUSE A CHECK VALVE TO LEAK?
A. A DIRTY OR DAMGED CHECK DISC
B. DAMAGED CHECK SEAT
C. BROKEN OR DAMAGED SPRING
D. ALL OF THE ABOVE

A

D. ALL OF THE ABOVE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

WHY IS THE RELIEF VALVE OF A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER SPRING LOADED?
A. TO REDUCE THE INCOMIN PRESSURE
B. TO FORCE THE RELIEF VALVE TO OPEN
C. TO FORCE THE #1 CHECK VALVE TO OPEN
D. TO FORVE THE RELIEF VALVE CLOSE

A

B. TO FORCE THE RELIEF VALVE TO OPEN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

WHICH OF THE FOLLOWING IS INCLUDED IN A HIGH HAZARD CLASSIFICATION?
A. RADIOACTIVE WASTE
B. RAW SEWAGE
C. CAUSTIC SODA
D. ALL OF THE ABOVE

A

D. ALL OF THE ABOVE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

THE PURPOSE FOR TESTING THE DIFFERENTIAL PRESSURE ON A BACKFLOW ASSEMBLY IS TO _________.
A. TO CHECK THE SPRING TENSION
B. TO MAKE SURE THE CHECK IS SEATED
C. TO RECORD FOR TEST REPORT
D. ALL OF THE ABOVE

A

D. ALL OF THE ABOVE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

WHAT MAY CAUSE BACKSIPHONAGE IN A WATER DISTRIBUTION SYSTEM?
A. THE LOSS OF PRESSURE CAUSED BY A RUPTURED PIPE
B. HIGH DEMAND FOR WATER
C. CHANGE IN DIRECTION OF FLOW
D. ALL OF THE ABOVE

A

A. THE LOSS OF PRESSURE CAUSED BY A RUPTURED PIPE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

A 1/4” DIAMETER POTABLE WATER SUPPLY SHALL HAVE AN AIR GAP SEPARATION BETWEEN THE SUPPLY PIPE AND THE FLOOD LEVEL RIM OF AT LEAST THIS MUCH.
A. 1/2”
B. 1”
C. 2”
D. 4”

A

B. 1”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

WHICH OF THE FOLLOWING DOES NOT DETERMINE THE TYPE OF TEST PROCEDURE TO BE USED WHEN TESTING BACKFLOW ASSEMBLIES?
A. THE SIZE OF THE ASSEMBLY
B. THE TYPE OF ASSEMBLY
C. THE MANUFACTURER OF THE ASSEMBLY
D. BOTH A AND C

A

D. BOTH A AND C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

THE PERFORMANCE REQUIREMENTS FOR BACKFLOW PREVENTION ASSEMBLY TEST KITS RECOMMENDS THE TEST EQUIPMENT BE CHECK FOR CALIBRATION AT LEAST ______.
A. MONTHLY
B. QUARTERLY
C. SEMI-ANNUALLY
D. ANNUALLY

A

D. ANNUALLY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

WHAT WOULD YOU WRITE ON YOUR REPORT IF YOU FOUND A PRESSURE VACUUM BREAKER ASSEMBLY INSTALLED ON A BOILER?
A. PRESSURE VACUUM BREAKER ASSEMBLY SHOULD NOT BE INSTALLED HERE.
B. REDUCED PRESSURE PRINCIPLE ASSEMBLY SHOULD BE INSTALLED HERE.
C. DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY SHOULD BE INSTALLED HERE.
D. BOTH A & B

A

D. BOTH A & B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

WHICH OF THE FOLLOWING DEVICES MAY BE USED TO CONTROL THERMAL EXPANSION PROBLEMS?
A. SOFT SEATING CHECK VALVES
B. PRESSURE RELIEF VALVES
C. THERMAL EXPANSION TANKS
D. BOTH

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

A DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY MAY NOT BE USED TO PROTECT AGAINST ______.
A. CONTAMINANTS
B. POLLUTANTS
C. BACKPRESSURE
D. BACKSIPHONAGE

A

A. CONTAMINANTS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

WHICH OF THE FOLLOWING IS NOT A REQUIRED PART OF AN ATMOSPHERIC TYPE VACUUM BREAKER?
A. AIR INLET FLOAT VALVE
B. THE BODY
C. AIR CANOPY
D. SHUT-OFF VALVE

A

D. SHUT-OFF VALVE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

THERMAL EXPANSION _________________________________________.
A. IS THE PRESSURE INCREASE WHICH OCCURS IN A PIPING SYSTEM EVERY TIME A WATER HEATER COMES ON TO HEAT MORE WATER.
B. OCCURS IN ANY HOT WATER SYSTEM WHEN WATER IS HEATED OR RECOVERED DURING PERIODS OF NON-USE.
C. CAN CAUSE A DANGEROUS INCREASE IN PRESSURE.
D. ALL OF THE ABOVE ARE TRUE

A

D. ALL OF THE ABOVE ARE TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

WHILE TESTING A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER A FLUCTUATION IN THE PRESSURE DIFFERENTIAL DURING A STATIC CONDITION IS CAUSED BY _________.
A. RAPID CHANGE IN SUPPLY PRESSURE
B. BACKPRESSURE BACKFLOW
C. LEAKIGN #1 CHECK VALVE
D. LEAKING #2 CHECK VALVE

A

A. RAPID CHANGE IN SUPPLY PRESSURE

18
Q

WHICH SHUT-OFF VALVE WOULD HAVE TO BE CLOSED BEFORE A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER ASSEMBLY CAN BE COMPLETELY TESTED?
A. SHUT-OFF VLAVE #1 ONLY
B. SHUT-OFF VALVE #2 ONLY
C. NEITHER SHUT-OF VALVES, #1 & #2
D. BOTH SHUT-OFF VALVES, # 1 & #2

A

B. SHUT-OFF VALVE #2 ONLY

19
Q

IF THE AIR INLET VALVE OF THE PRESSURE VACUUM BREAKER ASSEMBLY WILL NOT SEAT _________.
A. IT SHOULD BE WIRED CLOSED
B. CHECK VALVE SHOULD BE REMOVED
C. CANOPY COVER SHOULD BE REPLACED
D. THE SUPPLY PRESSURE IS TOO LOW

A

D. THE SUPPLY PRESSURE IS TOO LOW

20
Q

STATIC PRESSURE IS ____________.
A. PRODUCED BY FLUID IN MOTION
B. THE FORCE EXERTED BY A FLUID AT REST
C. THE FORCE EXERTED BY A CHANGE IN ATMOSPHERIC PRESSURE
D. NONE OF THE ABOVE

A

B. THE FORCE EXERTED BY A FLUID AT REST

21
Q

WHEN FIELD TESTING A BACKFLOW PREVENTION DEVICE IN A CONFINED SPACE, WHICH OF THE FOLLOWING GUIDLINES SHOULD BE FOLLOWED?
A. REVIEW THE PROCEDURE(S) TO FOLLOW IN CASE OF EMERGENCY.
B. PERFORM ALL OF THE WORK AS A TEAM.
C. TEST ATMOSPHERE BEFORE ENTERING THE CONFINED SPACE.
D. ALL OF THE ABOVE

A

D. ALL OF THE ABOVE

22
Q

THE RELIEF VALVE OF A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTOR OPERATES FROM THE INLET WATER PRESSURE AND THE WATER PRESSURE AT THE ____________.
A. #2 SHUT-OFF VALVE
B. ATMOSPHERIC VENT
C. #4 TESTCOCK
D. INTERMEDIATE ZONE PRESSURE

A

D. INTERMEDIATE ZONE PRESSURE

23
Q

WHEN TESTING A RELIEF VALVE ON A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTOR ASSEMBLY, WHICH TEST COCKS SHOULD OPEN?
A. TEST COCKS 1 & 3
B. TEST COCKS 1 & 4
C. TEST COCKS 2 & 3
D. TEST COCKS 3 & 4

A

C. TEST COCKS 2 & 3

24
Q

WHICH OF THE FOLLOWING IS NOT A CAUSE OF BACKPRESSURE?
A. ELEVATED PLUMBING
B. THERMAL EXPANSION
C. PUMPS
D. ASPIRATION

A

D. ASPIRATION

25
TO EXERT A PRESSURE OF 1 PSI AT THE BASE OF A COLUMN OF WATER, THE COLUMN WOULD HAVE TO BE ____________ IN HEIGHT. A. 4.34" B. 12" C. 14.7" D. 27.75"
D. 27.75"
26
TO OBTAIN AN OPTIONAL LINE-PRESSURE READING WHILE TESTING A DOUBLE CHECK VALVE BACKFLOW PREVENTION ASSEMBLY, A SUITABLE PRESSURE GAUGE IS ATTACHED TO WHICH TEST COCK? A. TEST COCK #1 B. TECK COCK #2 C. TEST COCK #3 D. TEST COCK #4
A. TEST COCK #1
27
A PRESSURE VACUUM BREAKER ASSEMBLYS SHUT-OFF VALVES ____________. A. ARE INSTALLED AT THE INLET OF THE ASSEMBLY ONLY B. ARE NOT USED DURING A FIELD TEST PROCEDURE C. CONTAIN AN INLET TEST COCK ON ALL ASSEMBLIES D. ARE LOCATED AT THE INLET AND OUTLET OF ALL ASSEMBLIES
D. ARE LOCATED AT THE INLET AND OUTLET OF ALL ASSEMBLIES
28
WHAT INFORMATION IS NOT REQUIRED ON THE BACKFLOW ASSEMBLY FIELD TEST REPORT? A. TYPE AND ASSEMBLY B. SERIAL # OF ASSEMBLY C. WATER TEMPERATURE OF ASSEMBLY D. TEST RESULTS
C. WATER TEMPERATURE OF ASSEMBLY
29
IF YOU FOUND A DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY INSTALLED ON A SERVICE LINE TO A PUMPING STATION FOR A MUNICIPAL SEWAGE TREATMENT SYSTEM, WHAT WOULD YOU RECORD ON YOUR REPORT? A. THE DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY SHOULD BE REPLACED WITH AN AIR TAP TYPE. B. THE DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY SHOULD BE REPLACED WITH A DUAL CHECK TYPE. C. THE DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY IS THE CORRECT APPLICATION AND NO CHANGES ARE NEEDED. D. NONE OF THE ABOVE
D. NONE OF THE ABOVE
30
THE PURPOSE OF THE ASSE PROFESSION QUALIFICATION STANDARD SERIES 5000 IS TO ___________. A. ESTABLISH MINIMUM PERFORMANCE CRITERIA FOR BACKFLOW ASSEMBLY TESTERS. B. ESTABLISH MINIMUM PERFORMANCE CRITERIA FOR BACKFLOW ASSEMBLY REPAIR WORKERS. C. ESTABLISH MINIMUM PERFORMANCE CRITERIA FOR BACKFLOW ASSEMBLY SURVEYORS. D. ALL OF THE ABOVE
D. ALL OF THE ABOVE
31
WHICH OF THE FOLLOWING CONDITIONS WOULD NOT CAUSE A PROPERLY OPERATING PRESSRUE DIFFERENTIAL VALVE TO OPEN? A. LARGE PRESSURE FLUCTUATIONS B. LEAKING #2 CHECK VALVE WITH BACKPRESSURE C. LEAKING #2 SHUT-OFF VALVE D. LEAKING #1 CHECK VALVE
C. LEAKING #2 SHUT-OFF VALVE
32
THE MINIMUM REQUIREMENTS FOR AN APPROVED AIR GAP SEPARATION SHALL BE AT LEAST __________. A. SEVEN TIMES AS LARGE AS THE EFFECTIVE OPENING OF THE SUPPLY PIPE. B. 6" ABOVE THE OUTLET OF THE SUPPLY PIPE C. TWICE THE SIZE OF THE EFFECTIVE OPENING OF THE SUPPLY PIPE BUT NOT LESS THAN 1" D. 12" ABOVE THE SURROUNDING GROUND OR FLOOR
C. TWICE THE SIZE OF THE EFFECTIVE OPENING OF THE SUPPLY PIPE BUT NOT LESS THAN 1"
33
ALL BACKFLOW ASSEMBLIES ARE REQUIRED TO HAVE _________. A. CHECK VALVE B. TEST COCK C. AT LEAST ONE ISOLATION VALVE D. ALL OF THE ABOVE
D. ALL OF THE ABOVE
34
BEFORE TESTING THE #1 CHECK VALVE OF A DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY YOU MUST FIRST ___________. A. ATTACH THE HIGH PRESSURE HOSE TO THE #3 TEST COCK B. ATTACH THE LOW PRESSURE HOSE TO THE #2 TEST COCK C. CLOSE SHUT-OFF VALVE #1 D. FLUSH ALL FOUR TEST COCKS
D. FLUSH ALL FOUR TEST COCKS
35
A DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY TEST AND MAINTENANCE REPORT SHALL INCLUDE ALL OF THE FOLLOWING INFORMATION EXCEPT FOR THE __________. A. ADDRESS OF THE INSTALLATION B. SERIAL # OF THE ASSEMBLY C. TEST RESULTS OF CHECK VALVE #1 D. DIFFERENTIAL PRESSURE RELIEF VALVE DISCHARGE READING
D. DIFFERENTIAL PRESSURE RELIEF VALVE DISCHARGE READING
36
FOR CONTAINMENT PROTECTION IN A LOW HAZARD SITUATION, THE MINIMUM PROTECTION REQUIRED SHALL BE __________. A. REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER B. TWO SINGLE CHECK VALVES IN SERIES C. DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY D. ATMOSPHERIC TYPE VACUUM BREAKER
C. DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY
37
IN ADDITION TO THE AIR GAP SEPARATION THE RECOMMENDED BACKFLOW PROTECTION FOR THE POTABLE WATER SUPPLY TO A PUMP USED FOR HANDLING A RAW SEWAGE IS ______________. A. DOUBLE CHECK DETECTOR ASSEMBLY BACKFLOW PREVENTER B. DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY C. REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER D. PRESSURE VACUUM BREAKER ASSEMBLY
C. REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER
38
A BACKFLOW PREVENTER WITH INTERMEDIATE ATMOSPHERIC VENT MUST BE INSTALLED TO ALLOW __________ A. DRAINAGE BETWEEN THE CHECK VALVES B. FULL PORT FLOW C. HORIZONTAL FOW D. HYDRAULIC SHOCK RELIEF
A. DRAINAGE BETWEEN THE CHECK VALVES
39
POTENTIAL CROSS CONNECTIONS CAN BE ___________. A. BEST PROTECTED WITH AN ATMOSPHERIC VACUUM BREAKER B. CONTROLLED WITH WATER PRESSURE C. PERMITTED BY A PLUMBING INSPECTOR D. NUMEROUS, VARIED AND UNPREDICTABLE
D. NUMEROUS, VARIED AND UNPREDICTABLE
40
THE FEDERAL LAW PLACING RESPONSIBILITY FOR THE PROTECTION OF THE PUBLIC WATER SUPPLY ON THE PURVEYOR OF THE WATER IS __________. A. OSHA B. THE SAFE DRINKING WATER ACT C. THE FDA UNICODE D. THE CLEAN WATER ACT
B. THE SAFE DRINKING WATER ACT