AN AIR GAP THAT IS CONSIDERED AFFECTED BY TWO INTERSECTING WALLS MUST ENCROACH UPON OR BE WITHIN A ZONE DEFINED AS _________ TIMES THE EFFECTIVE OPENING OF THE POTABLE WATER OULET IN WIDTH.
A. 1 1/2
B. 2
C. 3
D. 4

A

B. 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

WHICH OF THE FOLLOWING IS A MEANS OF CONTROLLING THERMAL EXPANSION?
A. T&P RELIEF VALVE
B. WATER HAMMER ARREXTOR
C. PRESSURE REFULATOR AFTER THE METER
D. THERMAL EXPANSION TANK

A

D. THERMAL EXPANSION TANK

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

WHAT IS THE MAXIMUM HEIGHT FOR A PERFECT VACUUM (AT SEA LEVEL) TO RAISE WATER IN A PIPE?
A. 21’
B. 26’
C. 30’
D. 33.9’

A

D. 33.9’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

DURING NORMAL OPERATION THE RELIEF VALVE ON A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER REMAINS CLOSED DUE TO ____________.
A. SUPPLY SIDE PRESSURE
B. DIRECT CROSS-CONNECTION
C. ZONE PRESSURE
D. CHECK VALVE #1

A

A. SUPPLY SIDE PRESSURE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

WHAT TYPE OF CROSS-CONNECTION IS A SUBMERGED HOSE BIBB (WITH NO HOSE ATTACHED)?
A. ACTUAL
B. POTENTIAL
C. PERMENANT
D. NONE OF THE ABOVE

A

A. ACTUAL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

WHAT PROTECTS THE POTABLE WATER SUPPLY TO A URINAL EQUIPPED WITH FLUSHOMETER VALVE?
A. REDUCED PRESSURE PRINCIPLE BACKFLOW ASSEMBLY
B. DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY
C. ATMOSPHERIC TYPE VACUUM BREAKER
D. PRESSURE VACUUM BREAKER ASSEMBLY

A

C. ATMOSPHERIC TYPE VACUUM BREAKER

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

WHAT IS THE PURPOSE OF THE SPRING IN THE RELIEF VALVE ASSEMBLY OF A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER?
A. TO FORCE THE RELIEF VALVE OPEN
B. TO FORCE THE RELIEF VALVE CLOSED
C. TO FORCE THE RELIEF VALVE CLOSED
D. BOTH B & C

A

A. TO FORCE THE RELIEF VALVE OPEN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

WHICH OF THE FOLLOWING IS USED TO CONTROL THERMAL EXPANSION PROBLEMS?
A. SOFT SEATING CHECK VALVES
B. PRESSURE RELIEF VALVES
C. EXPANSION TANK
D. BOTH B & C

A

D. BOTH B & C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

WHAT IS THE SUGGESTED MINIMUM DISTANCE BETWEEN THE RELIEF VALVE DISCHARGE PORT OF A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER ASSEMBLY AND THE FLOOD LEVEL RIM OF THE SURROUNDING AREA?
A. 6”
B. 12”
C. 18”
D. 24”

A

B. 12”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

DURING A FIELD TEST OF A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER YOU FIND A LEAKING #2 CHECK VALVE. AT THIS POINT YOU SHOULD MAKE REPAIRS TO THE ASSEMBLY AND?
A. RETEST #2 CHECK VALVE
B. RETEST THE ENTIRE ASSEMBLY
C. RETEST #1 CHECK VALVE
D. APPROVE THE ASSEMBLY AS IS

A

B. RETEST THE ENTIRE ASSEMBLY

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

WHAT IS THE REQUIRED TYPE OF PROTECTION BETWEEN A POTABLE WATER SYSTEM AND THE BUILDING SEWER SYSTEM?
A. DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY
B. PRESSURE VACUUM BREAKER ASSEMBLY
C. AIR GAP SEPARATION
D. BACKWATER VALVE

A

C. AIR GAP SEPARATION

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

WHAT IS THE MAXIMUM FLOW TEMPERATURE FOR THE HOSE BIBB VACUUM BREAKER?
A. 120 DEGREES
B. 140 DEGREES
C. 160 DEGREES
D. 180 DEGREES

A

D. 180 DEGREES

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

WHAT IS THE PURPOSE OF TESTING THE DIFFERENT PRESSURES ON A BACKFLOW ASSEMBLY?
A. TO CHECK THE SPRING TENSION
B. TO MAKE SURE THE CHECK IS SEATED
C. TO RECORD FOR THE TEST REPORT
D. ALL OF THE ABOVE

A

D. ALL OF THE ABOVE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

WHAT IS THE MINIMAL ACCEPTABLE PRESSURE DIFFERENTIAL ACROSS THE CHECK VALVES WHEN TESTING A DOUBLE CHECK DETECTOR FIRE PROTECTION BACKFLOW PREVENTER ASSEMBLY?
A. 0.5 PSI
B. 1.0 PSI
C. 2.0 PSI
D. 3.0 PSI

A

B. 1.0 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

ASSE STANDARD 1037 (FLUSHOMETERS FOR PLUMBING FIXTURES) REQUIRES ___________.
A. ATMOSPHERIC VACUUM BREAKER
B. REDUCED PRESSURE PRINCIPLE ASSEMBLY
C. AIR GAP SEPARATION
D. DOUBLE CHECK VALVE ASSEMBLY

A

A. ATMOSPHERIC VACUUM BREAKER

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

WHEN TESTING A REDUCED PRESSURE PRINCIIPLE BACKFLOW PREVENTER _____________.
A. THE RPESSURE DROP ACROSS THE #1 CHECK VALVE MUST BE 1.0 PSID.
B. THE PRESSURE DIFFERENTIAL RELIEF VALVE IS HYDRAULICALLY DEPENDENT AND MECHANICALLY INDEPENDENT.
C. THE PRESSURE DROP ACROSS THE #2 CHECK VALVE MUST BE AT LEAST 5.0 PSID.
D. THE PRESSURE IN ZONE 2 (REDUCED PRESSURE ZONE) MUST EXCEED SUPPLY PRESSURE FOR THE RELIEF VALVE TO DISCHARGE.

A

B. THE PRESSURE DIFFERENTIAL RELIEF VALVE IS HYDRAULICALLY DEPENDENT AND MECHANICALLY INDEPENDENT.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

WHAT WILL YOU WRITE ON YOUR TEST REPORT IF YOU FIND A PRESSURE VACUUM BREAKER ASSEMBLY INSTALLED ON A BOILER FEED LINE?
A. PRESSURE VACUUM BREAKER ASSEMBLY SHOULD NOT BE INSTALLED WHERE IT IS SUBJECT TO BACKPRESSURE.
B. REDUCED PRESSURE PRINCIIPLE ASSEMBLY SHOULD BE INSTALLED IN PLACE OF THE PVB.
C. DOUBLE CHECK BACKFLOW PREVEDNTION ASSEMBLY SHOOULD BE INSTALLED IN PLACE OF THE PVB.
D. BOTH A & B

A

D. BOTH A & B

18
Q

WHICH TEST COCK MAY BE OPENED TO ESTABLISH FLOW THROUGH A BACKFLOW PREVENTION ASSEMBLY?
A. TEST COCK #1
B. TEST COCK #2
C. TEST COCK #3
D. TEST COCK #4

A

D. TEST COCK #4

19
Q

WHICH OF THE FOLLOWING IS AN INCREASE OF PRESSURE IN A CLOSED SYSTEM DUE TO THE HEATING AND EXPANDING OF WATER?
A. RELIEF VALVE
B. BACKPRESSURE
C. THERMAL EXPANSION
D. BTU

A

C. THERMAL EXPANSION

20
Q

A HOSE CONNECTION BACKFLOW PREVENTER IS HIGH HAZARD PROTECTION VALVE THAT CONTAINS TWO ____________.
A. CHECK VALVES
B. ISOLATION VALVES
C. VENT PORTS
D. INTERMEDIATE ZONE PRESSURE

A

C. VENT PORTS

21
Q

WHEN INSTALLING A CROSS-CONNECTION COTROL DEVICE YOU SHOULD CONSIDER ____________.
A. SIDEWALL CLEARANCES
B. DEGREE OF HAZARD
C. THE DISTANCE BETWEEN THE BACKFLOW DEVICE AND THE FLOOR LEVEL.
D. ALL OF THE ABOVE

A

D. ALL OF THE ABOVE

22
Q

A SUB-ATMOSPHERIC PRESSURE CAN ALSO BE REFERRED TO AS _______________.
A. PSID
B. PSIA
C. BACKPRESSURE
D. VACCUUM

23
Q

A CARBONATED BEVERAGE MACHINE REQUIRES A BACKFLOW PREVENTER FOR BEVERAGE DISPENSING EQUIPMENT. THIS PROTECTION IS NEEDED BECAUSE OF?
A. THE CARBON DIOXIDE GAS
B. THE INCREASED ACIDITY OF THE WATER
C. THE HIGHER PH LEVEL AFFECTING HTE COPPER PIPE
D. ALL OF THE ABOVE

A

A. THE CARBON DIOXIDE GAS

24
Q

THRMAL EXPANSION ____________________.
A. IS THE PRESSURE INCREASE WHICH OCCURS IN A PIPING SYSTEM EVERY TIME A WATER HEATER COMES ON TO REPLACED HOT WATER THAT IS USED.
B. OCCURS IN ANY HOT WATER SYSTEM WHEN WATER IS HEATED OR RECOVERED DURING PERIODS OF NON-USE.
C. CAN CAUSE A DANGEROUS INCREASE IN PRESSURE.
D. ALL OF THE ABOVE

A

D. ALL OF THE ABOVE

25
THE #2 TEST COCK OF A DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY IS LOCATED? A. UPSTREAM OF THE #1 SHUT-OFF VALVE B. UPSTREAM OF THE #1 CHECK VALVE C. DOWNSTREAM OF THE #2 SHUT-OFF VALVE D. BETWEEN THE #1 AND #2 CHECK VALVE
B. UPSTREAM OF THE #1 CHECK VALVE
26
ACCORDING TO ASSE SERIES 5000 THE TEST RESULTS FOR ANY BACKFLOW PREVENTION ASSEMBLY SHOULD BE SENT TO _________. A. THE OWNER OF THE PROPERTY B. THE WATER PURVEYOR C. THE TENANAT OF THE PROPERTY D. ALL OF THE ABOVE
D. ALL OF THE ABOVE
27
THE SPRINGS ON THE TWO CHECK VALVES OF A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTR ARE _____________. A. LOCATED OUTSIDE THE BODY OF THE ASSEMBLY B. EXTERNALLY LOADED C. NOT INTERCHANGEABLE D. INTERCHANGEABLE
C. NOT INTERCHANGEABLE
28
A SMALL HOLE IN THE UNDERGROUND POTABLE WATER DISTRIBUTION SYSTEM MAY __________________. A. REDUCE THE INCOMING PRESSURE SIGNIFICANTLY B. ALLOW CONTAMINATION OF THE SYSTEM FROM BACKSIPHONAGE BACKFLOW (VENTURI EFFECT) C. CREATE BACKPRESSURE BACKFLOW D. INCREASE THE SYSTEM PRESSURE
B. ALLOW CONTAMINATION OF THE SYSTEM FROM BACKSIPHONAGE BACKFLOW (VENTURI EFFECT)
29
BACKFLOW CAN OCCUR WHENEVER THE PRESSURE IN A POTABLE WATER SYSTEM IS ___________ THE PRESSURE IN A NON-POTABLE PIPING SYSTEM AND THE TWO SYSTEMS ARE PHYSICALLY CONNECTED. A. GREATER THAN B. LESS THAN C. EQUAL TO D. ABOUT THE SAME
B. LESS THAN
30
WHAT IS THE REQUIRED BACKFLOW PREVENTION ASSEMBLY FOR A FIRE SUPPRESSION SYSTEM CONTAINING CHEMICALS? A. REDUCED PRESSURE DETECTOR FIRE PROTECTION BACKFLOW PREVENTION ASSEMBLY OR REDUCED PRESSURE PRINCIPLE ASSEMBLY. B. DOUBLE CHECK DETECTOR FIRE PROTECTION BACKFLOW PREVENTION ASSEMBLY OR DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY. C. PRESSURE VACUUM BREAKER ASSEMBLY D. DUAL CHECK VALVE TYPE BACKFLOW PREVENTER
A. REDUCED PRESSURE DETECTOR FIRE PROTECTION BACKFLOW PREVENTION ASSEMBLY OR REDUCED PRESSURE PRINCIPLE ASSEMBLY.
31
A BACKFLOW PREVENTER WITH INTERMEDIATE ATMOSPHERIC VENT MUST BE INSTALLED TO ALLOW ____________. A. DRAINAGE BETWEEN THE CHECK VALVES B. FULL PORT FLOW C. HORIZONTAL FLOW D. VERTICAL FLOW
A. DRAINAGE BETWEEN THE CHECK VALVES
32
THE #2 CHECK VALVE ON A REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER ASSEMBLY IS TESTED BY APPLYING PRESSURE ___________. A. UPSTREAM OF THE #2 CHECK VALVE B. DOWNSTREAM OF THE #2 CHECK VALVE C. IN THE PRESSURE DIFFERENTIAL ZONE D. FROM TEST COCK #4 TO TEST COCK #1
B. DOWNSTREAM OF THE #2 CHECK VALVE
33
DIFFERENTIAL PRESSURE GAUGES SHOULD BE STORED WITH ALL NEEDLE VALVES ______________________. A. CLOSED AND HOSES DRAINED B. PARTIALLY OPENED C. OPENED AND HOSES DRAINED D. REMOVED
C. OPENED AND HOSES DRAINED
34
WHICH OF THE FOLLOWING IS AN ACCEPTABLE BACKFLOW PREVENTION ASSEMBLY? A. SWIVEL CONNECTION B. SPOOL PIECE C. 2 SWING CHECKS IN TANDEM D. NONE OF THE ABOVE
D. NONE OF THE ABOVE
35
THE MECHANICAL COMPONENTS OF A HOSE CONNECTION VACUUM BREAKER INCLUDE ________________. A. TEST COCK B. CHECK VALVE AND VENT C. PRESSURE REGULATOR D. SHUT-OFF VALVE
B. CHECK VALVE AND VENT
36
THE FOLLOWING ABSOLUTE PRESSURE COULD CAUSE BACKSIPHONAGE TO OCCUR IN A HYDRAULIC SYSTEM (DISTRIBUTING SYSTEM) AT SEA LEVEL. A. 10.5 PSIA B. 15.0 PSIA C. 33.9 PSIA D. 100 PSIA
A. 10.5 PSIA
37
SUPPOSE YOU HAVE TWO COLUMNS OF WATER THAT ARE BOTH 100' IN HEIGHT. IF ONE COLUMN HAS A DIAMETER OF 6" AND THE OTHER HAS A DIAMETER OF 1", WHICH WOULD YOU SAY IS TRUE ABOUT THE PRESSURE AT THE BOTTOM OF THE TWO COLUMNS? A. BOTH COLUMNS WOULD HAVE 43.3 PSI B. THERE IS NOT ENOUGH INFORMATION TO DETERMINE THE PRESSURE C. THE 6" LINE WOULD HAVE A HIGHER PSI READING THAN THE 1" LINE D. BOTH COLUMNS WOULD HAVE 100 PSI
A. BOTH COLUMNS WOULD HAVE 43.3 PSI
38
A SYSTEM THAT INCLUDES ANY CHEMICAL INJECTOR MUST HAVE THE POTABLE SYSTEM PROTECTED WITH _________________. A. ATMOSPHERIC TYPE VACUUM BREAKER B. DUAL CHECK VALVE TYPE BACKFLOW PREVENTER C. PRESSURE VACUUM BREAKER D. REDUCED PRESSURE PRINCIPLE ASSEMBLY
D. REDUCED PRESSURE PRINCIPLE ASSEMBLY
39
WHICH OF THE FOLLOWING WILL NOT CREATE A CLOSED LOOP PIPING SYSTEM? A. PRESSURE RELIEF VALVE B. CLOSED GATE VALVE C. DUAL CHECK VALVE TYPE BACKFLOW PREVENTER D. DOUBLE CHECK BACKFLOW PREVENTION ASSEMBLY
A. PRESSURE RELIEF VALVE
40
AN INDIRECT CROSS CONNECTION ALLOWS WHAT TYPE OF BACKFLOW TO OCCUR? A. BACKPRESSURE B. INDIRECT C. BACKSIPHONAGE AND BACKPRESSURE D. BACKSIPHONAGE
D. BACKSIPHONAGE