Total Coliform and Ecoli Flashcards
(28 cards)
Length of time for record retention - Microbiology
5 years
How is sunlight an interference
may hydrolyze indicator compounds resulting in a false positive
Bleach concentration for sample collection
1 oz per gallon
Shelf life of raw TSB media
unopened - 2 years
opened - 6 months (1 year in dessicator)
TSB weight/ volume prep ratio
30 +/- 0.01g to 1000 mL DI water
TSB autoclave time and temp
119-121*C 12-15 min on slow
must NOT sit in autoclave for more than 45 min from door closing
final pH of TSB
7.3 +/- 0.2
shelf life of prepared TSB pre sterilization
3 months R, 1 week RT
Sterilization of Neg Control Water
119-121*C for 30 min on slow
Sample Collection steps
Flush tap for about 1 min
Sanitize tap for about 2 min
Fully open and flush tap for 3-5 min
Take chlorine reading (free and total)
Aseptically collect sample
What is the preservative used to remove chlorine?
Sodium Thiosulfate
Maximum holding time for Bacteria samples
30 hours refrigerated
Volume/ headspace of collection
100 mL with 1 inch of headspace
Over 100 mL sample?
Under 100 mL sample?
over - aseptically adjust volume to 100 mL
under - sample rejected due to insufficient volume (re-collect)
For potable bacteria samples, Colilert or Colisure?
Colisure
What is a sample set defined as?
up to 60 samples who have an inclusive incubation time of 4 hrs, with one POS and one NEG control
After the addition of Colisure, how long can samples sit prior to incubation?
30 min
Incubation temp and time
35.0 +/- 0.5 *C
Colilert- 24 to 28 hrs
Colisure- 24 to 48 hrs
Colisure result interpretations for Total Coliform:
No Color Change - Neg. for Total Coliform
Color Change - Yellow to Magenta, Pos. for total Coliform
Colisure result interpretations for E. Coli:
No Fluorescence - Neg. for E. Coli
Fluorescence - Pos. for E. Coli
Analyst QC requirements
Certified analysts are required to preform test at least once a month
Total number of bottles for TSB sterility check
1%, no more than 4
Autoclave time and temp for contaminated bacteria materials
119-121*C for 45 min
Autoclave sterility testing is required how often and by what method?
once every 3 months, by either commercially manufactured check solution or by TSB inoculation