Training Bulletins Flashcards
(167 cards)
Fleet services should be called for an air loss in the brake system of..
1lb per 10 mins
10lbs per application
App. 3.2.4
A reading of __ volts or higher would indicate the voltmeter on the apparatus is over charging
14.8 volts
App 3.2.4
The apparatus oil pressure should be between ___ to ____ psi when operating at 1500 to 2100 rpm
30 to 70
App 3.2.7
When should the electric fuel pump on the apparatus be tested?
Weekly. For 5 secs with the ignition off
When should the tower ladder/ aerial ladder emergency hydraulic system be tested?
Weekly. Test for a maximum of 30 secs
When should engine oil be checked?
Daily. With the engine off and has been cooling down for 15 mins
App 3.2.6
The aerial ladder and TL boom should be lubricated how often ?
Monthly. Inspect and lube as needed
App 3.4.1
Max speed with snow chains?
30 mph
App add 1
Dimensions of the vehicle recovery strap.
Members should maintain a ____ ft safety zone when towing.
30ft x 4”
35’
Max weight of 20,000 lbs
App add6
How many sections are there to the ladder on an aerial
4 sections. One stationary 3 sliding
Aerial width with stabilizers down
18’ 4”
5’ 2” each side
What hydrant connections can be used when first due engine?
10’ small hydrant connection
35’ soft hydrant connection
3 1/2” hose for inline pumping or when hydrant is unlawfully blocked (35’ soft hydrant will not reach)
When other than first to arrive on the first alarm, what hydrant connections should be used?
10’ small connection
35’ soft connection
10’ hard suction
What hydrant connections should an engine use when arriving at second or greater alarms?
10’ hard suction
Failure of the scba’s PRA’s primary system will automatically direct air into a secondary system. When this occurs, the operating pressure will only be reduced to ___ psi .
150
The PRA on the SCBA reduces pressure to ___ psi
100
Failure of both the primary and secondary systems on the PRA will activate a relief valve and discharge all pressure in excess of ____ psi into the atmosphere.
185
When this occurs, partially close cylinder valve
How is A full cylinder is indicated on the heads up display?
Two glowing green lights
How is 3/4 cylinder indicated on the heads up display?
A single green glowing light
How is half a cylinder indicated on the heads up display?
Yellow light flashing slowly at once a second
How is One quarter cylinder indicated on the heads up display ?
Red light at far left flashing rapidly at ten times a second
If the scba batteries are dying, what conditions occur?
The sensor module will chirp every two second and the green light on the control module will go out
How many batteries are used in the Scott pack?
6 double As
When does the scba get inspected?
Immediately after 0900 and 1800 roll calls
Before the start of multi unit drill
After each use