Training Bulletins Flashcards
(99 cards)
Who is responsible for the maintenance schedules of the apparatus?
Company commander
What is the normal volt meter reading for the apparatus
- 5-14.2
14. 8 or higher system is over charged and contact fleet services
T or F
1lb of air loss per 10min in brakes is ok.
True. And max of 10lbs per application
T or F
You should wait a min of 15min after engine is shut down to check the oil
True
When tires tread reaches ____ request replacement
3/16”
On the apparatus what are 5 things that get checked weekly?
1- tire pressure 2 transmission fluid with engine running 3 power steering fluid 4 air cleaner should be green 5 electric fuel pump primer - 5 sec with rig on but not running
How often are the tower ladders and aerial ladders inspected?
Monthly
Vehicle recovery strap How big is it? Who can get pulled out with it? Where do you attach it? How big is the safety zone? Can anyone be in the rig being towed?
30’ x 4”
Chief rigs and ambulances can be towed (not for engines or ladders)
Only attach to frame mounted eye hooks, never to front or rear bumper
35’ safety zone
Vehicle being towed, operator stays in and everyone else out
Security decal
Where does it get placed?
Do you approach a vehicle without one?
Who do you notify is it is missing?
Fixed adjacent to drivers side door
Do not approach, contact dispatcher and report how many, type, and location via mixer OFF
Notify fleet services if missing
When lowering out riggers when do you use ground pads?
At all times
What is idle pump pressure when in volume? When in pressure?
Volume =55psi
Pressure = 100psi
Which connection should you use (10’ small, 35’ soft, 10’ hard) A- 1st on 1st alarm B- other than 1st on 1st alarm C- arriving at 2nd or greater alarms D- drafting
A- 1st on 1st alarm = 10’ small or 35’ soft
B- other than 1st on 1st alarm = any of the three
C- arriving at 2nd or greater alarms = 10’hard should be used
D- drafting = 10’hard MUST be used
Do you connect to the hydrant or pumper first?
Hydrant than pumper
When pressure drops below __psi you must be augmented
Below 15psi
Scba cylinder
How long is the service life?
How often do they get hydrostatically tested?
When do spare cylinders get checked?
15yr service life
Hydrostatically tested every 5 yrs (escape cylinders every 3yrs)
Spares get checked weekly on mondays
The PRA
Primary reduces pressure to?
Secondary reduces pressure to?
If primary and secondary fail the relief valve will expell pressures above?
Primary 100psi
Secondary 150psi
Both fail 185psi
*when the primary fails the vibra alert will activate
T or F
When primary and secondary PRA fail and excess pressure about 185 is being expelled you should partially close the cylinder valve.
True
A full cylinder can be depleted in __min through the face piece.
4 min
What do you do if the regulator fails in the open position (SCBA)
Open purge fully and partially close cylinder valve.
HUD Display on SCBA
How long to all the lights light for when turned on?
Are the HUD lights and the vibra alert independent of each other?
What shape and where is the battery light?
20 seconds
Yes they are independent of each other
Red circular light to the right
Where can you get a back up small or XL face piece?
Division
When you put the face piece on what straps get tightened first?
Top or bottom
Bottom
What do you do when a member cannot get a good seal with any size face piece?
Safety and MSU immediately notified
Company commander forwards report detailing details and actions talked to bureau of ops
Member will not operate in areas requiring SCBA until solved
How can you identify cracks on the threads of a cylinder
Bight silver line along threads indicates cracks