Utility Emergencies Flashcards

(58 cards)

1
Q

If any doubt concerning your ability to manage a incident involving gases or leaks request

A

HAZMAT Unit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Methane has a vapor density of __ making it _____ than air

A

.55. Lighter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A note of caution is that natural gas in transmission pipelines and rail cars is _____ odorized, with ______

A

Not, Mercaptan

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The flammable range for methane is _ % to __%

A

5% to 15%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

ignition temperature for natural gas is about ______

A

1200 degreees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Markers show the pipeline’s approximate location

A

Not its exact location

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When shutting off the gas at the appliance, the shut off valve will be a quarter turn,

A

just prior to the regulator and appliance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

outside gas leaks and other outside gas emergencies, engine companies shall position the apparatus

A

prior to and upwind

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

general rule for apparatus positioning is no closer than ___
For the first arriving unit and a minimum distance of __

A

100 feet
300 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

During gas emergencies the second engine should stage at ____ outside the hot zone

A

The hydrant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Gas line over ___inches in diametershould be upgraded to an HAZMAT event

A

2 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

During a outside gas leak what is dispatched

A

1 engine
1 truck or rescue

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Ensure who should be called enroute to a gas emergency

A

Gas Company

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

If gas is leaking prior to a shut off and no gas is entering any structure the best course of action is

A

No action

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

fire department personnel shall ensure no persons enter a trench deeper than ___ that is not shored

A

5 Feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

To protect the utility company workers, units should position upwind with a ______ and a _____

A

20 LB dry chemical
Charged hose line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

All non-essential personnel, including firefighters and civilians, shall be kept out of the hot zone. The DOT Emergency Response Guide (ERG) suggests an evacuation distance ____

A

330 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Gas lines are buried around ___ below the surface

A

24”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Gas lines have a _____ _____ ____ over them for gas company can detect them.

A

Yellow coated wire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

If a gas line is on fire the best procedure is to _____

A

Protect exposures

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

If a gas meter is on fire the best place to shut off is the ______

A

Curb valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Consideration must be given to a potential ignition source being an auxiliary generator. If the power to a structure is shut off at the electric panel this action may cause the generator to operat

A

Secure the generator prior to operating the electric panel.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

After a pipelines delivers gas to an occupancy, use of a regulator reduces the pressure of the gad between __ to ___ psi to between __ / __ psi before gas passes through the occupancy gas meter

A

40 and 200 psi
1/2 psi and 1/4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

What are the two types of gas meters ____ and ____

A

Outside and inside

25
All inside or enclosed gas installations are required to have the regulator vented to the outside via piping and must be within _ of the vent on an inside wall
5 feet
26
When the gas meter is involved, and access to the meter shut off cannot be accessed, the best place to shut off the gas is at the
Curb
27
Propane has an expansion ratio of
270:1
28
Carbon Monoxide Emergencies dispatch
1 engine company 1 EMS unit
29
CO alarm 10-35 35-100 100 or greater
Inform occupants to have a technician check appliances Ventilate structure and see if occupants need medical attention Evacuate structure and full PPE and SCBA
30
Ground transformer After power is removed it is recommended to extinguish any remaining fire with
dry chemical or CO2 extinguishers,
31
When attempting to control gas service to an occupancy firefighters may control gas at the _____ ____ valve
Curb box Do not attempt to shut off gas in manholes or street box
32
A vent pipe indicates what?
Interior gas meter
33
Battalion 404 from E423, E424 is staged at the corner of Little River TPKE and Guinea Rd. We have a crew of 3 performing RECON, side Alpha of the Delta exposure. The structure a a is a 2 story SFD, nothing evident Conduct lap
34
LEL operations 0-10% 10-25% 25% or greater
Investigate Investigate with SCBA Evacuate
35
When operating in an IDLH on a gas leak, member should use a ______ and ______ to protect personnel in the hot zone
Dry chemical extinguisher Hose line
36
While investigating one fire fighter should remain by the engine and the other firefighter should bring _________ and AMD devices
Dry chemical extinguisher and AMD
37
When personnel determine that fire is gas-fed, who shall be notified
Command and request for utilities to shut down
38
First due engine on a inside or outside gas leak is to identify a hydrant ___ ft from incident address
300
39
Tactics When a propane tank vents and product is burning personnel should ____ the tank
Cool
40
Electricity has tow basic properties
Voltage and current
41
Ground transformer fire Once power has been removed personnel should consider using ______ or _______
Dry chem or CO2 extinguisher
42
If fire department turns off sprinkler system in a commercial building who must be notified
Fire inspection officer or fire Marshall office
43
A regulator reduces the pressure of the gas from between ___ and ____ psi between 1/2 and 1/4
40 and 200
44
Most commercial and all residential appliances use gas pressure of ___ and ___
1/2 and 1/4
45
During the size up, unit officers should complete _____ of the structure
360 lap
46
10-25% LEL
Continue to investigate utilizing an SCBA
47
48
When members working in the hot zone, what must be used for protection
Dry chemical extinguisher and hose line
49
If personnel encounter a smell of natural gas with no gas appliances personnel should check ____ for odors from HVAC units rooftop lines
Rooftop
50
When personal determine that a structure fire is gas fed…who shall be notified ______and what should shall be regulated
Command Shut down a gas line
51
Propane tank, Person should ____ the tank
Cool
52
CO alarm Personnel should refrain from ______
Ventilation
53
Occupancy should be evaluated if CO reading reach above
100 PPm
54
If fire department turn off sprinkler system in a commercial building, who shall be notified
Fire inspection department or fire marshal office FYI: the occupancy may need to have a fire watch until system can be restored
55
56
Where is the safest place for the fire department to lock out power.
Electrical panel
57
If firefighters have to access interstitial space in a structure who shall be contacted ______ _____
Building engineer
58
If a ground transformer is on fire, fire department personnel shall wait until power is shut off by utility company and remaining fire should be extinguished with ______ or ______
CO2 or Dry chem