116 Aircraft Hazard Areas Flashcards
You can CQ any section except Safety... (27 cards)
Weather Radar Hazard Area for Personnel
60 foot radius for personnel.
Weather Radar Hazard Area for Possible Fuel Ignition
300 foot radius for possible fuel ignition.
Weather Radar Hazard Area for Possible Electro-Explosive Device Detonation
100 foot radius for possible electro-explosive device detonation.
Degree Arc for all Weather Radar Hazard Areas
240 degrees.
HF Radio Hazard Area for Personnel
10 foot radius for personnel. No external aircraft skin contact or headsets connected to external ICS jacks.
HF Radio Hazard Area for Fuel Ignition (HF and UHF)
200 foot radius for possible fuel ignition.
HF Radio Hazard Area for Possible Electro-Explosive Device Detonation
150 foot radius for possible electro-explosive device detonation.
UHF Satcom & UHF C3 Radio Hazard Area for Personnel
- 1 foot radius with UHF C3 HPA off or UHF SATCOM transmitting for personnel
- 17 foot radius with UHF C3 HPA ON for personnel
UHF Satcom & UHF C3 Radio Hazard Area for Possible Fuel Ignition
200 foot radius for possible fuel ignition.
DNS TX Antenna Hazard Areas
- 4 foot radius for DNS TX Antenna 2 with system in LOW POWER
- 10 foot radius for DNS TX antenna 1 when transmitting
FAB-T Hazard Area Exposure Time for Personnel
6 minutes.
FAB-T Hazard Area for Personnel Inside the Main Beam
168 feet for personnel inside main beam.
FAB-T Hazard Area for Personnel Outside the Main Beam
5 feet for personnel outside main beam.
FAB-T Hazard Area for Electro-Explosive Inside Main Beam
124 feet for electro-explosive inside main beam.
FAB-T Hazard Area for Electro-Explosive Outside Main Beam
31 feet for electro-explosive outside main beam.
MR-TCDL Ku Hazard Area Exposre Time for Personnel
6 minutes.
MR-TCDL Ku Hazard Area for Personnel Inside Main Beam
40 feet for personnel inside main beam.
MR-TCDL Ku Hazard Area for Personnel Outside Main Beam
3 feet for personnel outside main beam.
MR-TCDL Ku Hazard Area for Electro-Explosive Inside Main Beam
22 feet for electro-explosive inside main beam.
MR-TCDL Ku Hazard Area for Electro-Explosive Outside Main Beam
2 feet for electro-explosive outside main beam.
MR-TCDL Ka Hazard Area for Personnel Inside Main Beam
68 feet for personnel inside main beam.
MR-TCDL Ka Hazard Area for Electro-Explosive for Personnel Outside Main Beam
4 feet for electro-explosive outside main beam.
INMARSAT Hazard Area for Personnel
8 foot radius when transmitting through the HGA.
INMARSAT Hazard Area for Possible Electro-Explosive Device Detonation
150 foot radius for electro-explosives when transmitting through the HGA.