1
Q

Accessible toilets MUST be mounted at ___ to ___ AFF to top of toilet seat.

A

17”, 19”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Two exit access doorways MUST be provided from any space where the Occupancy Load exceeds ___. Give Occupancy groups this applies to.

A

49 = Occupancy Groups A (Assembly), B (Business) and M (Mercantile); 29 = Occupancy Group S (Storage)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Audio/visual fire signal device mounting height

A

6’-8” to 7’-6” AFF

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

4 locations there MUST be a audio/visual fire signal device

A

restroom, hallway, lobby and general assembly area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

ALL electrical receptacles MUST be ____ AFF.

A

18”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Clearnace of ____ deep MUST be provided in front of power panels.

A

36”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Door openings should have a ___” minimum clear space on the push side of the door

A

12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

ALL acessible (barrier-free) upper cabinets or shelves located above a work surface MUST NOT exceed ____ AFF.

A

44”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Service (reception/transaction) counters over ____ in length MUST have an acessible height service counter, a minimum of ____ in length.

A

8’-0”, 36”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Means of Egress minimum height clearance

A

7’-6”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

MIMIMUM interior corridor width

A

44”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Accessible urinals MUST have an elongated rim at a maximum heihgt of ___ AFF.

A

17”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Fire extinguishers MUST be located no more than ____ from furthest occupant.

A

75 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the dimensions of the clear floorspace that must be provided in front of accessible lavatories, urinals, showers and bathtubs?

A

30” x 48”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Grab bars at toilets and showers to be mounted between ___ and ___ AFF.

A

33”, 36”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

All accessible (barrier-free countertops, sinks, service surfaces and horizontal work surfaces MUST NOT exceed ____ AFF with a ____ High clear knee space below.

A

34”, 27”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

ALL acessible (barrier-free) lower cabinets MUST have a ___ maximum depth and a ___ minimum toe-kick

A

6”, 9”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Centerline of accesssible toilets MUST be ____ to ____ from side wall or partition.

A

16”, 18”

19
Q

Minimum # of fire extinguishers calculation

A

1 extinguisher per 3000 sq. ft.

20
Q

Door assemblies in a 1-hour fire rated parition MUST have a minimum fire protection rating of…

A

20 minutes and be self-closing

21
Q

Grab bar at rear of toilet to be ___ long.

A

36”

22
Q

Common path of egress travel distance MUST NOT exceed ____ feet.

A

100

23
Q

Dead end corridors MUST NOT exceed ____ in length.

A

20’-0”

24
Q

Core drills MUST NOT be within ___ of any structural element.

A

18”

25
Q

Emergency illumination shall be provided for a minimum of ____ hours in event of failure of normal lighting.

A

1.5

26
Q

Minimum turning radius clearance at all changes of travel direction on any path of travel

A

60” radius

27
Q

Doors opening from occupied spaces into the path of egress travel shall not project more than ___” into the required width.

A

7

28
Q

Accessible showers MUST be a minim of ___ x ___.

A

30” x 60”

29
Q

Three paritions that must be one hour fire rated

A
  1. Demising partitions between tenant spaces
  2. Paritions along public corridor
  3. Demise an Assembly (with occupancy of 750 sq. ft. or greater)
30
Q

Travel distance MUST NOT exceed ____ feet measured along path of travel.

A

250

31
Q

Protruding objects minimum height along path of egress, including any corrior, aisle or passageway.

A

6’-8”

32
Q

Exit access doorways MUST be placed at a distance that is equal or greater than one-_____ of the maximum overall diagnal dimension of the area being served, when it is or is not sprinkled?

A

half, NOT sprinkled; third, sprinkled

33
Q

Door openings should have a ____” minimum clear space on the pullside of the door.

A

18

34
Q

ALL accessible showers MUST have grab bars on ____ sides.

A

three

35
Q

ALL acessible (barrier-free) wall-mounted controls MUST be located between ___ and ___ AFF for side reach.

A

9”, 48”

36
Q

Clearance around accessible toilets MUST be ____ along rear wall and _____ along side wall.

A

60”, 56”

37
Q

Maximum square inches for door or sidelight glazing in fire rated partition

A

240 sq. in.

38
Q

ALL electrical receptacles located with in ___ of a water source MUST be ____.

A

36”, GFI

39
Q

All Objects located on a wall between ___” and ___” AFF MUST NOT protrude more than ___” into an egress path of travel.

A

27, 80, 4

40
Q

Fire rating for storage rooms

A

1-hour rating if over 100 sq. ft.

41
Q

Grab bar at long side of toilet MUST be ____ long.

A

42”

42
Q

ALL acessible (barrier-free) wall-mounted controls MUST be located between ___ and ___ AFF for forward reach.

A

15”, 44”

43
Q

Accessible mirrors MUST be mounted with the edge of the reflective surface no higher than ____ AFF.

A

40”