CER Progress Test Three Flashcards

(75 cards)

1
Q

All endoscopes should be high-level disinfected or sterilized between each patient: True or False

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Not drying an endoscope properly after HLD and rinsing can allow for recontamination of the endoscope: True or False

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Adding more high-level disinfectant to the soak basin or AER to bring the solution up to the desired level also extends the length of time the solution can be used. True or False

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Automated endoscope reprocessor device connectors are designed to be used with any flexible endoscope: True or False

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When using an AER with an automated cleaning cycle, it is still necessary to thoroughly manually clean the endoscope before using the automated cycle. True or False

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The high level disinfectant solution in an AER should be tested for the minimum effective concentration: True or False

A

Before each use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

PPE should be changed before removing an endoscope from an AER or soak basin. True or False

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Most multi-part flexible endoscopes and their accessories must be disassembled for sterilization. True or False

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When the color of chemical indicator tape used to seal flat wrap changes, it indicates that the item is sterile. True of False

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

All flexible endoscopes should have a ventilation adaptor or water-resistant cap in place when undergoing ethylene oxide sterilization. True or False

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Packaging material approved for hydrogen peroxide plasma sterilization include:
a. paper plastic pouches
b. muslin
c. Tyvek pouches
d. all the above

A

Tyvek pouches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Routine personal and area monitoring of the work area is required when using hydrogen peroxide plasma and ethylene oxide sterilization methods. True or False

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Biological indicator monitoring is required for each cycle run in:
a. ethylene oxide
b. hydrogen peroxide gas plasma
c. vaporized hydrogen peroxide
d. all the above

A

Ethylene oxide

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

A device’s design can present a challenge to the sterilization process. True or False

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When carrying flexible endoscopes, they should always be held at the:
a. distal end
b. proximal end
c. light cable connection area
d. control head

A

Control head

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Cross contamination while handling contaminated endoscopes can be prevented by using:
a. directional workflow
b. personal protective equipment
c. proper signage
d. all the above

A

All the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Flexible endoscope components that have been removed for cleaning should always be kept with the same endoscope because they will be easier to track. True or False

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Filtered air is used to help reduce the risk for contamination during storage. True or False

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

High level disinfected flexible endoscopes should be reprocessed:
a. after 72 hours
b. after seven days
c. every Monday
d. at a time interval determined by the facility

A

At a time interval determined by the facility

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Arthroscopes are used for surgeries on:
a. sinus cavities
b. ureters
c. pelvic organs
d. joints

A

Joints

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Sterilized flexible endoscopes should be stored:
a. in the same manner as high level disinfected endoscopes
b. in closed cabinets
c. on solid wire shelving in the sterile storage area
d. in the same manner as other sterilized devices

A

In the same manner as high level disinfected endoscopes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

The rod lenses of a rigid endoscope are made from:
a. fiber optics
b. reflective metal rods
c. glass
d. prisms

A

The rod lenses of a rigid endoscope are made from glass

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

When using a rigid endoscope, a dark image may be caused by damaged:
a. illumination fibers
b. coupler
c. camera
d. all the above

A

all the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Using the wrong size light cable can cause damage to a rigid endoscope: True or False

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
After manual cleaning, rigid endoscopes should be placed in an automated washer-disinfector for thorough cleaning: True or False
False
25
During inspection of a rigid endoscope, it is important to check the: a. internal optics b. image c. distal end under magnification d. all the above
All the above
26
Rigid endoscopes that are approved for steam sterilization can also be IUSS. True or False
False
27
Visual examination of the interior structures of the body is called: a. visioscopy b. endoscopy c. fiberoscopy d. botoscopy
Endoscopy
28
Along with benefits to the patient, endoscopic procedures benefit the facility by: a. reducing procedure time b. freeing up operating rooms c. reducing operating costs d. eliminating the need for surgery
reducing procedure time
29
The insertion tube of a flexible endoscope can contain the: a. instrument channel b. control head c. scope body d. light guide connector
Instrument channel
30
The most complex type of endoscope is the: a. semi-rigid endoscope b. hysteroscope c. laparoscope d. flexible endoscope
Flexible endoscope
31
It is important to understand the quality documentation requirements for endoscope reprocessing: True or False
True
32
This endoscope is designed to examine upper airways: a. bronchoscope b. rhinolaryngoscope c. duodenoscope d. choledochoscope
Rhinolaryngoscope
33
This endoscope is often used to treat kidney stones: a. duodenoscope b. hysteroscope c. ureteroscope d. cystoscope
Ureteroscope
34
The endoscope universal cord: a. contains the handheld controls b. enables the physician to perform procedures, such as biopsies c. connects the light connector to the control body d. is the part inserted into the patient
Connect the light connector to the control body
35
A bronchoscope can be used to examine the airways: True or False
True
36
Ureteroscopes are used to view the tubes that connect the kidneys to the bladder. True or False
True
37
Hysteroscopes are used to visualize the: a. larynx b. abnormalities of the urinary track c. uterus d. colon
Uterus
38
39. Endoscopes can become contaminated from: a. poor manufacturer's processing instructions b. using contaminated water c. damage d. all the above
All the above
39
Bacteria spore are resistant to: a. radiation b. heat c. chemicals d. all the above
All the above
40
Endospores are formed: a. outside the bacteria cell b. inside the bacteria cell c. during the bacterial reproduction d. after the bacteria has died
Inside the bacteria cell
41
Biofilm is a colony of one type of bacteria that joins together. True or False
False
42
Biofilm and fungus can form underneath fingernails. True or False
True
43
Sepsis has been associated with: a. bronchoscopy b. duodenoscopy c. upper gastrointestinal endoscopy d. All the above
All the above
44
Endoscopes that have been high-level disinfected should be stored on open wire shelving: True or False
False
45
When airflow is negative, that means air flows into that area: True or False
True
46
Doors and pass-through windows between the decontamination and disinfection area should remain closed, however, they may remain open between the disinfection and sterilization area: True or False
False
47
When sending endoscopes from the user area to the decontamination area, endoscopes and their accessories, such as forceps and wires, should be transported together in the same closed container: True or False
False
48
When physical barriers between soiled and clean areas are not possible, the use of ______ can minimize the risk of cross contamination. a. policies b. procedures c. training d. all the above
ALl the above
49
Low humidity in the work area can: a. promote bacterial growth b. cause absorbent materials to become excessively dry c. increase the risk of cross contamination d. all the above
Cause absorbent materials to become excessively dry
50
The process of rendering a clinically used device safe and ready for reuse is the definition of: a. decontamination b. disinfection c. reprocessing d. sterilization
The process of rendering a clinically used device safe and ready for reuse in the definition of: reprocessing
51
Household liquid dishwashing detergents are recommended as the detergent of choice to clean gastrointestinal endoscopes: True or False
False
52
Personal protective equipment for the endoscope decontamination area includes: a. full length face shield or a mask and eye protection b. lightweight short-sleeved gown or jumpsuit c. long-sleeve warm up jackets d. All the above
Full length face shield or a mask and eye protection
53
Detergents used to clean endoscopes should be: a. low foaming b. alkaline c. non residue producing d. all the above
low foaming
54
Solutions that are mixed too strong will not be as effective as solutions mixed to the required strength: True or False
True
55
The most common pH recommended for endoscope cleaning chemicals is: a. low pH b. High pH c. Medium pH d. Neutral pH
Neutral pH`
56
Pre-cleaning at the point of use should occur before the endoscope is disconnected from the power source: True or False
True
57
After removing the flexible endoscope from the patient, the first step in point-of-use pre-cleaning is to: a. flush the insertion tube b. pre-rinse the inner channels c. remove the gross soil d. attach the video cap
Remove the gross soil
58
Leak testing should be performed: a. after point of use pre-cleaning b. before manual cleaning c. after every procedure d. all the above
all the above
59
The purpose of leak testing is to: a. ensure the cleaning solution will not leak out of the endoscope b. ensure all the inner channels are full of cleaning solution c. detect damage to the exterior and interior of the endoscope d. all the above
Detect damage to the exterior and interior of the endoscope
60
When performing a leak test, the water-resistant cap should be removed: True or False
False
61
When cleaning an endoscope that has failed a leak test, it is important to first disconnect the leak tester: True or False
False
62
The exterior of the endoscope should be cleaned using lint-free cloths or sponges: True or False
True
63
All removable parts should be carefully cleaned using a stiff bristled brush. True or False
False
64
When cleaning the lumens of an endoscope, the brush should be rinsed before pulling it back through the channel. True or False
True
65
Borescopes are used to visually inspect the channels of an endoscope: True or False
True
66
Tests for cleaning efficacy of the manual cleaning process should be performed at least weekly; however, daily is recommended: True or False
True
67
Cleaning equipment should be tested for cleaning efficacy: a. upon installation b. after repair c. on a routine basis d. all the above
All the above
68
Reusable accessories such as snare wires, water bottles and biopsy forceps should be placed in the same container as the endoscope to help ensure that all components from a procedure are kept together: True or False
False
69
Using poor technique or skipping leak testing can cause harm to the patient: True or False
True
70
When inspecting an endoscope light cord, broken light fibers can be detected by: a. using a borescope b. small nicks in the sheath c. black spots on the end of the cord d. scratches in the lumens
Black spots on the end of the cord
71
Visual inspection of flexible endoscopes should occur: a. before the procedure b. during the procedure c. after cleaning d. all the above
All the above
72
Ethylene oxide sterilization of a flexible endoscope may result in a blown endoscope if: a. the endoscope is not vented properly b. the endoscope's internal channels are moist when sterilized c. the endoscope has a cracked lens d. the distal tip is not protected
the endoscope is not vented properly
73
Early detection of endoscope damage can protect the patient and: a. decrease the processing time b. is required by the US FDA c. reduce repair costs d. all the above
Reduce repair costs
74
Enzymatic cleaning solution used for endoscope cleaning should be discarded after each use: True or False
True