Ch. 4 - Positioning Apparatus Flashcards
(125 cards)
- Act of preparing to manage an incident at a particular location or a particular type of incident before an incident occurs.
Preincident Planning
p136
Incident scene _____-____ determines the most advantageous position for the attack pumper.
size-up
p136
- Ongoing evaluation of influential factors at the scene of an incident.
Size-Up
p136
- Person in charge of the Incident Command System and responsible for the management of all incident operations during an emergency.
Incident Commander
p136
When positioning the apparatus:
* Pull the apparatus past the ______ of the ________, if feasibl, when arriving at an incident where no fire is evident ( ____________ mode). This position allows personnel on the apparatus to view three sides of the building.
front of the building / investigation mode
p136
When positioning the apparatus:
* Consider the best access point for ?
personnel and equipment entering the occupancy when parking the apparatus
p137
A fire department pumpers primary function on the fireground is to provide?
water directly for fire streams or to support other pumpers or aerial apparatus
p136
When positioning the apparatus:
* _________ with the apparatus (based on local policy) in the event connections for water supply or fire department connections need to be made or to assist in pulling attack hoseline and operating the pump.
Remain
p137
______ _______ is the first tactical priority at any incident.
Life safety
p137
If there is indication of an obvious rescue situation, position the apparatus to facilitate the most efficient deployment of _________ _________ ( or _______ ________ if so equipped).
ground ladders / aerial device
p137
What is a primary concern of the d/o and company officer in the placement of the pumper?
establishing water supply
p137
The d/o should be aware that supply lines, especially LDH, may block?
the access of later-arriving apparatus
p137
Only after a proper size up confirms the location and extent of the fire can a pumpers onboard tank be considered for ?
water supply
p137
Attempt to position the apparatus _________ of an incident whenever possible.
upwind
p138
Positioning upwind may negate the need for the d/o to wear protective __________ _________ while operating the vehicle and reduce the possibility of the apparatus becoming an _________ if fire conditions worsen.
breathing apparatus / exposure
p138
Apparatus and personnel should be downhill of the main body of fire as ___________ fires move uphill faster than on flat terrain or downhill.
wildland fires
p138
When laying supply hose into a fire scene, lay the hose to the side of the _______ if at all possible.
street
p138
Apparatus and personnel should maintain a collapse zone of at least _____ and a ______ times the height of any building determined likely to collapse.
one and half times
p138
The ________ of a structure are generally considered the safest position should a collapse occur.
corners
p138
Depending on the incident, apparatus, equipment, and personnel operating within ______ feet of the base of a high-rise fire may need to be protected from falling glass and debris.
200 feet
p139
If a building is less than _____ floors tall, the _______ _______ should be positioned on the side of the street closest to the building and aerial apparatus are placed outboard of the pumpers.
5 floors / attack pumper
p140
If a fire building is greater than five floors tall how should attack pumpers and aerial apparatus be positioned?
the attack pumper takes the outside position to allow the aerial apparatus maximum reach to the building.
p140
In order to supply a fire department connection most efficiently, a pumper should position as closely as possible to the _______ _______.
water source
- Point at which the fire department can connect into a sprinkler or standpipe to boost the water pressure and flow in the system.
Fire Department Connection (FDC)
p141