Controllers Flashcards

1
Q

How many measured values can be shown on the MET800 series display?

A

3

you can also show the totalizer at the bottom

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many measurements can be stored on the SD card in the VEGAMET86x?

A

170K

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The new VEGAMET’s are for water and wastewater industry.

A

True

they can be used in other industries but primary for W and WW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The VEGAMET 862 can power and support how many 4-20 mA HART sensors.

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The new VEGAMETs are considered Signal Conditioners.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The new VEGAMET 800 series can be commissioned or set up with?

A

Bluetooth

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

VEGAMET Commissioning has Four Golden Rules: Installation/Mounting, Application, Adjustment and

A

False Signal Suppression

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

True or False: The two types of applications most commonly used for VEGAMET’s are Parshall Flume and V-notch Weir.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

In a V-notch Weir, it is recommended that the sensor is mounted at least ____ times the maximum head height.

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where is the 0 reference point of the PULS C21 and PULS31?

A

Tip of the antenna cover

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The VEGAPULS 69 provides the following features:

A

Non Contact measurement
Non mechanical measurement
Tight beam angle <4degrees

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The most meaningful way to determine weight is to transfer known weight of material into a silo and adjust the scale.

A

Certainty (repeatable and reliable)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

A VEGA cellular gateway provides:

A

Ability to configure troubleshoot the measurement devices remotely
the ability to be completely separate from the plant’s network
a wireless connection to the internet for inventory data transmission

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The VIS portal provides easy access to real-time inventory to

A

those with the authorized access (UN and PW)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Not a cementitious material

A

admixture

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

From a logistics optimization standpoint, inventory “certainty” is more important than inventory “accuracy”.

17
Q

Not a good application for VIS?

A

weight measurement for batching purposes

18
Q

China produced more concrete in 3 years than the US did in the 20th century

19
Q

The VEGAPULS 69 measures

20
Q

Not a good application for VIS

A

High and low level alarming

Operator interface to the plant process

21
Q

How many radars can be connected to a VEGASCAN 693 with the EX output option (Single chamber sensors that must be set to HART Multidrop with unique addresses)?

22
Q

What is / are the primary function(s) of the VEGATOR 100 Series?

A

Switching and isolation/barrier

23
Q

How many radars can be connected to a VEGASCAN 693 (Single chamber sensors that must be set to HART Multidrop with unique addresses)?

24
Q

What is the maximum wiring distance for a VEGADIS 81?

25
What VEGA sensor communications options are available for most transmitters?
4-20mA HART Profibus PA Foundation Fieldbus Modbus 485 RTU
26
What is the maximum recommended distance for Bluetooth PLICScom with the VEGA Tools app or VEGA DTMs with PACTware?
25m
27
What does IIoT stand for?
Industrial Internet of Things
28
What is the primary function(s) of the VEGATRENN Series?
4-20mA signal transmission and isolation - intrinsically safe power to the switch Galvanic isolation - separates hazardous area power from ordinary areas HART repeating isolation barrier
29
What software solution do you recommend for a customer who wants to monitor 12 tank levels and trend the history? The customer would also like to have notifications of low and high levels.
VIS
30
Which controller is used with a VEGASWING 61 with mA step-change electronics so the customer does not have to perform the annual wet test? (Note: The wet test is the customer having to physically remove the sensor(s) and perform a bench test once a year.)
VEGATOR 121 or 122
31
The VEGAMET 862 can power and support how many 4 … 20 mA HART sensors?
2
32
What is the only way that the new VEGAMET 800 series controllers can be fully commissioned?
Bluetooth
33
Customers can access the HTML webpages in the VEGAMETs and VEGASCANs with Ethernet communication options via which web browser(s)?
IE, Chrome, firefox (mozilla)
34
How many measured values can be displayed on the new VEGAMET 800 series display?
3
35
What is the VEGA communicator that connects to a laptop or PC via USB and is used to commission most VEGA sensors with VEGA DTMs and PACTware?
VEGACONNECT
36
NOT a good use of the VEGA Inventory System?
For accurate weight measurement for batching purposes