Switch Flashcards

1
Q

Which newly introduced sensors have helped VEGA complete its portfolio for the Food, Beveraga and Pharma Industries?

A

Point Level

Pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The VEGA tools app allows you to configure and diagnose on both the pressure and point level sensors with Bluetooth

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Ceramic pressure cells offer which benefits

A

Extremely abrasion resistant
long term stability
higher measurement accuracy
low maintenance requirements

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How many color options does the 360 degrees switching status offer on the newly introduced VEGA devices?

A

256

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The VEGAPOINT 30 series is meant for liquids

A

False - it is meant for light bulk solids while the VEGA 10 and 20 are meant for liquids

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Can the VEGAPOINT 23 be programmed to tell the difference between buildup and submersion in product?

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

5 Different switch technologies

A

Vibration, Capacitance, Microwave Barrier

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Vibration Switches

A
Liquids and solids
VEGASWING
VEGAWAVE
VEGAWIB
Plug and play
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

VEGASWING - Vibration switch

A

Vibration Switch

1200 Ghz - Piezo drive - if SG = 0.5 or lighter forks won’t respond. Look for frequency being damped. For liquids

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

VEGAVIB - Vibration switch

A

Vibration Switch
350 Hz. Look for amplitude being damped
For granular solids. Carbocer coating (reduces dust).
Detection of solids under water. Can do level under waver (point level no continuous)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

VEGAWAVE - Vibration switch

A

Vibration Switch
200 Hz. Look for amplitude being damped
Detection of solids under water.
Can do level under waver (point level no continuous)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Tight spaces no approvals

A

VEGASWING 51

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

VEGASWING 63

A

Ammonia - endless length up to 6 meters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Microwave Barrier Switch

A
Liquids and solids
sentitivity adjustment
time delay for falling product
works just like radar 
high temperature option available
PULS 62 basically - 26 GHz
ceramic on one end
level detection independent of the medium
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

VEGAMIP

A
Anything you do with a PULSE 62 you can do with VEGAMIP. Set up is done in the receiver
VEGAMIP T61 Emitter - needs power
VEGAMIP R 61 Receiver - needs power
VEGAMIP R 62
High temps and abrasive
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Capacitance Switches

A
Liquids and solids
Conductive and non conductive options
monitors change in standing capacitance
requires set up in actual use (must see product)
once set up very repeatable
sticky products - very good!
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

VEGASWING 66

A
High temperatures
High Pressures
-196 C to 450 C temperature distance piece
inconel 718 material on forks
inductive drive
second line of defense (ceramic)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Capacitance

A

The ability of a body to hold an electrical charge and the amount of that charge is measure in picofarads

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Conductive limit switches - no approvals

A

Liquids
Switch point adjustment - rod/cable length
point level indication

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

VEGASWING series 50

A

Vibration point level switches for liquids
VEGASWING 51 = compact (not good with sticky products)

VEGASWING 53 = extended up to 1m
Not continuous LED like the VEGA POINT
3 individuals LEDs depending on switch estate - red, yellow, green
No bluetooth can not configure
IO link available
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

VEAPOINT series 10,20,30

A

VEGAPOINT 10 and 20 = Liquids

VEGAPOINT 30 = solids

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

PNP for transistor connection

A

Switch the plus on the output

PNP = sourcing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

NPN for transistor connection

A

Switch the negative on the output

NPN = sinking

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

NO equals MIN

A

Normally open you have o volts then when it hits the setpoint then you have 24 volts
NO=MIN (OUT 2)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
NC equals Max
Normally closed you have 24 volts then when it hits setpoint then you have 0 volts NC = MAX (OUT 1)
26
VEGAPOINT 21
Water based media (more than 10% water) | & oils and sticky media
27
VEGAPOINT 31
Bulk solids
28
Difference between VEGAPOINT 21 & VEGAPOINT 31
Factory programming 21 set up for liquids 31 set up for solids You can use 31 to measure liquids and 21 for solids - this is just for customers when ordering online
29
VEGAPOINT series 10
``` Can be used in 100C (212F environment) ultra compact no adjustment No Bluetooth only threaded connection light ring is output ```
30
VEGAPOINT series 20, 30
Can be used in 115C (239F environment) Adjustable with PACTware the VEGA Tools app or IO-Link version with extended switch point up to 3ft includes temperature sensor - you can look up process temperature ISO 4400 Available
31
Our customer wants to measure maple syrup which instruments should we suggest?
VEGASWING 51 - not good with sticky product VEGAPOINT 11 - will work, but may not account for buildup VEGAPOINT 21 - Definitely will work VEGAPOINT 23 - Definitely will work VEGAPOINT 31 - preset from factory for solids
32
VEGASWING or VEGAPOINT Measure Liquids
VEGASWING - plug and play | VEGAPOINT - with adjustment
33
VEGASWING or VEGAPOINT Bulk or solids
ONLY VEGAPOINT | NO VEGASWING
34
VEGASWING or VEGAPOINT Adjustment can be ordered "customer - specific"
``` ONLY VEGAPOINT (TopVis configuration) NO VEGASWING ```
35
VEGASWING or VEGAPOINT Completely metallic
VEGASWING = GOOD | NO VEGAPOINT
36
VEGASWING or VEGAPOINT Hygienic design (Spray Shadows)
VEGAPOINT - smaller easier to clean
37
VEGASWING or VEGAPOINT Hygienic design Gaps and materials
VEGASWING - completely welded and seal
38
VEGASWING or VEGAPOINT Detection of builup
VEGAPOINT great | No VEGASWING only liquids with viscosity < 10000mPAS
39
VEGAPOINT - Optimized for food and pharmaceutical
Cleaning CIP/SIP suitable completely welded, stainless steel version with no light ring and no Bluetooth (out SS body). Got to use I/O link 3A available & EHEDG
40
VEGAPOINT - Hygienic adapter
Pressure and Point level you can order with a threaded connection 3A capabilities
41
Switching outputs - 5 outputs available
Conctacless Electronics - cheaper to replace Relay Max 3 AMPS (Open/Close = wear out) Transistor - 3 wire device - direct to PLC 2 wire MA step change - needs VEGATOR 121 NAMUR - low voltage device because tehy want a battery power, needs VEGATOR 111
42
3 colors
Normal operation Switch status Failure mode
43
What is the maximum length of the VEGAPOINT 23?
1 meter - same way goes for VEGASWING 53
44
VEGAPOINT has a "measuring cell" temperature
True | on the 20 and 30 you can get it as an output on the I/O link
45
VEGAPOINT 31 is for liquids
false | VEGAPOINT 31 is for solids - should be known as solid switch
46
Is the resonance frequency available as a digital output
Yes with 3 wire IO - Link version only
47
Customer specific adjustment is possible for the VEGAPOINT in TopVis and the configurator
True | you can set timers, colors, resonance
48
The vibrating switches for liquids measure a change in ______?
frequency
49
Which instrument series is used for solids?
VEGAMIP VEGACAL VEGAWAVE
50
In what application is it preferable to use a capacitance switch instead of a vibration switch?
Foam
51
True or False: A bare or uncoated rod is recommended for VEGACAP instruments used with conductive products.
False
52
Which of the following is best suited for cryogenic applications?
VEGASWING66
53
There are five outputs for switching: Relay, 2wire step change, Namur and what are the last two
contactless | transistor
54
Which series of switching devices can be non-contact with the process media
VEGAMIP
55
How many GHz are emitted by the VEGAMIP transmitter?
26Ghz
56
How many color options does the 360̊ switching status offer on the VEGAPOINT 21, 23, and 31 devices?
256
57
Which series of switching devices is good for use with viscous and adhesive / sticky products?
VEGACAP
58
What needs to happen for capacitance to change from a steady state?
The plates needs to change size The plates need to get further away The process material between the plates needs to change dielectric
59
Which of the VEGAPOINT series is recommended for use with solids?
series 30
60
Which line of vibrating switches is used with liquids?
VEGASWING
61
The vibrating switches for solids measure a change in ________?
amplitud
62
True or False: The VEGAPOINT series of instruments has a “measuring cell” temperature
True
63
What is the maximum length of the VEGAPOINT 23?
1m
64
VEGAPOINT has a "measuring cell" temperature
True
65
VEGAPOINT 31 is for liquids
False
66
Is the resonance frequency available as a digital output?
Yes, with 3-wire IO-link version only
67
Customer specific adjustment is possible for the VEGAPOINT in TOpVis and the configurator
True