1
Q

Loss of all AC power

A

ADG manual deploy handle………pull

2
Q

EFB OVERHEAT/FIRE

A

If you notice your iPad and or battery are extremely hot or the EFB catches fire, conduct the following
Immediately remove external power source (external battery, if applic)
External power source……remove
Shut down the iPad
On/off, sleep/wake button (on top unit)…..hold
Red power off bar………………….Swipe from left to right
If fames are visible
Immediately isolate the iPad (floor of the flight deck between seats is recommended) and use the fire extinguisher on the flames
Do not smother the fire or cover with ice
Do not under any circumstance attempt to turn the iPad back on

3
Q

STAB TRIM RUNAWAY

A

Control wheel……………………………Assume manual control and override
Runaway
Stab trim disc switch………………….select

4
Q

ALERON SYSTEM JAMMED

A

Autopilot………………………….Disengage
Aileron controls (both)……….release pressure
Roll Disc handle……………….Pull, turn and lock
Airplane control………………..Transfer to pilot with operating aileron

5
Q

ELEVATOR SYSTEM JAMMED

A

Autopilot…………………………..Disengage
Elevator controls (both)………Release pressure
Pitch disc handle……………….Pull, turn and lock
Airplane control………………….Transfer to pilot with operative elevator

6
Q

RUDDER SYSTEM JAMMED

A

Yaw damper disc button…………Select

Rudder pedals……………………….Overpower

7
Q

BRAKE OVHT

A

Airspeed…………………..not more than 220 kias

Landing gear lever……..DN

8
Q

MLG BAY OVHT

A

Airspeed…………………..Not more than 220 kias

Landing gear lever……..DN

9
Q

ENGINE FIRE OR SEVERE ENGINE DAMAGE (on ground)

A

Note attempt to face the airplane into the wind

Parking brake…………………………….On
Affected thrust lever……………………Shut off
Affected Eng Fire Push switch…….Select
L and R Fuel Boost pumps switches…off
After 10 seconds and fire warning persists:
Both engine bottle switches……..select to discharge

10
Q

DOUBLE ENGINE FAILURE

A

Cont ignition…………………………………..On

If engine continue to run down (N2

11
Q

L (R) REV DEPLOYED

A

Affected thrust lever…………Confirm and idle

12
Q

HYD 1 HI TEMP

A

L HYD SOV switch………….Closed
Hydraulic page……………….Confirm L HYD SOV Closed
System 1 temperature……..Monitor

13
Q

APU FIRE

A

APU Fire switch………………..Select
If after five seconds and fire warning persists:
APU Bottle switch………Select to discharge

14
Q

DITCHING OR FORCED LANDING IMMINENT

A

L and R pack switches……………..Off
EMER Depress switch………………On
Just before contact:
EMER Depress switch………….Off

15
Q

PASSENGER EVACUATION

A

Tower (time permitting)…………………………………Advise
Parking brake………………………………………………On
GND Lift Dumping switch……………………………..Man disarm
Thrust levers………………………………………………..Shut Off
EMER Depress switch…………………………………..On
Evacuation command……………………………………Evacuate, evacuate,
EMER LTS switch (coincident with PA)…………….On
APU L and R ENG Fire Push switch…………………Select
Battery Master switch…………………………………….Off to prevent cvr erasure

16
Q

HYD 2 HI TEMP

A

R HYD SOV switch……………….Closed
HYDRAULIC page………………..Confirm R HYD SOV Closed
System 2 temperature…………..Monitor