Faults Comeng - Revision Flashcards

1
Q

When rescuing a train and you’re pulling it out of section and it has no pantos up, what cock do you need to turn?

A

Techav (to remove trip)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

???? Saloon lights - running emergency

A

Yes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Trips switches guages cocks, what’s next?

A

DC supply light

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Hiw can you tell you have no DC supply

A

No bell
LP flag raised

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the control res pressure

A

490kpa

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Effect on train if you have control res rupture

A

Line breakers fail to close

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If a control res has ruptured, what fault lights will you get?

A

Line switch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If you have a control res rupture how do you isolate motors?

A

Motors all out

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What can you press in the cab if you have traction issues

A

Traction overload

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Do we touch the main switch?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What 3 things are supplied by the 1500v DC

A

MA, compressors, traction motors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How many times does substation restart during overhead loss?

A

2x

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

During overhead loss what happens to doors?

A

Release

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Overhead loss - what will all trains in section be asked to do?

A

Lower pantos

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Overhead loss, with comms, at what time intervals will trains depart once overhead has been restored

A

One minute intervals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

During overhead loss and trains begin to clear the section again, what notch of power should they use?

A

Series

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

AC power items (3)

A

Non-emergency saloon lights (normal lighting)
Van area cab light
Operation of headlights

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Overhead loss and no comms, at which time of the clock will UP trains and DOWN trains move?

A

⬆️ 30 seconds
↕️ 60 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Overhead loss, how long will battery backup last?

A

2 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Wheb overhead power is lost, what fault light will flash on drivers fault panel?

A

Battery charger (to indicate a reset of the emergency lighting is required)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

What does the LSM do?

A

Protects the sub station from the train

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

LSM speed threshold for time delay?

A

8km

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Overhead loss, LSM activates when the output of MA’S drops below what voltage?

A

95vDC for 2 continuous seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

During overhead loss what two things are still available?

A

Emergency lighting
PA systrm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
LSM operation - train moving over 8km/h, BVICS open overhead lost, timers WITHIN 4 minutes - what does LSM do to train?
Lowers all trailing pantos Shuts down local MA Trips EP CB
26
Overhead loss - to locate defective train, Train Control will request drivers to do what?
Raise each panto individually Start each MA locally
27
Overhead loss - how many minutes until vicers times out?
5 minutes
28
Will traction overload button work if MAs have oversped
No
29
How to isolate rheo brakes?
Toggle switch
30
What does a steady air con light indicate
1 AC in 1 car down
31
What does a flashing aircon light indicate
More than 1 AC in 1 car down
32
Where is the fault if the wheel slip fault light illuminates while stationary?
Wheel slip unit
33
Wheel slip axle km difference
15km
34
What is part of the control CB
MRBOPC Master controller Reserver Rheo brake Traction overload Panto raise and lower Control govener
35
What happens to train if control CB trips?
Fail to power
36
If you're leading panto fails to raise, how will you get your pantos up?
Raise individually
37
If your pantos won't lower what happens to train?
Out of service
38
If control cb trips in trailing cab, what indication will you get in lead?
FDCL
39
???? Scenario based question about locating control CB trip cause
Reverser is the cause
40
???? Scenario based question about locating control CB trip cause
Rheo demand wire is the cause
41
How to isolate rheo train lined?
Flip EP CB
42
???? What is the lowest % of traction motors (isolated bogies?) can you continue driving with
50%
43
???? (Forget how the question was worded) Is 110v train lined?
Yes
44
How many MA'S need to be running for full saloon lighting?
All
45
1 MA running effect on train
Half saloon lighting each car Half AC each car Local rheo brake will be inoperative
46
Effect on train if no DC supply
Disabeld
47
Effect on MA If compressor governers fail in closed position
Run continuously
48
Effect on compressor governor if compressor governor cb tripped?
Isolates local compressor govoner
49
What would be the affect on the train if you pneumatically isolated a compressor governor by rhetorical isolating cock
Compressor runs continuously
50
Compressor running continuously what CB can we check and isolate?
Check and isolate local compressor govoner
51
Auxiliary circuit breaker components
BADSCARS Bell Auxiliary start Doors release and close Saloon lights on and off Couple and uncouple Aircon #1 control Local rheo brake Shcfenberg self centring
52
What connects to MR air
Picture
53
brakes available if MR ruptured in lead?
Emergency
54
MR ruptured in motor car, what do you need to do / isolate
Local Panto electrically and pneumatically Comp gov Motors all out Mr end cocks Release SPB
55
Mr rupture in trailer car, what have you lost/what needs to be isolated
Doors Air suspension End cocks
56
MR rupture in lead, do you need a competent employee?
Yes
57
brakes available if MR ruptured in lead centre
Air brake
58
What cocks to turn if MR tank ruptured?
MR delivery Isolate compressor govener
59
If isolated air suspension and you're in a 50 track speed zone what speed do you need to do?
25km ( restriction = max 30 or half track speed)
60
Effect on train if control res ruptures
Insufficient air to close line breakers
61
Leak in control res effect on train
line breakers cannot close
62
In addition to isolating control res cocks during a leak, what else must be isolated?
Motors all out
63
Whistle defect
Depress multiple times
64
If BP rupture, first thing we check
Derailed
65
If you see a sudden decrease in BP pressure, and you put controller to emergency then back to run and release and BP charges...what has happened?
Back tripped - trailing trip gear activated
66
BP rupture in cars 1,2 or 3 (on 6 car) can you drive from lead?
???? No lead driving
67
BP rupture car 3 - where would comp emp sit?
Lead
68
BP rupture in lead car 1 - during rescue what brakes do you have in the lead?
Spring Park brake
69
BP car 4 - do you need comp emp?
Do not need a competent employee
70
BP rupture car 5 and no competent employee, what brakes do you have?
EP
71
BP rupture in car 4 or 5 and no comp emp, what can you isolate on brake unit?
MR -> 7 step relay
72
BP leak in brake unit branch pipe between brake unit iso and trip valve iso speed restriction
10km less if above 60km (treat it as an isolated bogie)
73
Charging valve is closed in what position?
Emergency
74
???? Defect BP speed
15km
75
BP is failing to charge when in Run and release and bvic open - what can we check?
MR to Brake controller
76
Unable to free jammed charging valve do we need a competent employee?
Yes
77
Speed if charging valve not charging in lead ????
15km ????
78
Lockout magnet valve faulty in deenergise (open) positon brakes
Super brake - air ep and rheo working simultaneously
79
What to do if lockout magnet valve defective in closed (energised)
Place Brake controller into emergency Run EP/Rheo Restricted to 15km
80
Lock out magnet valve brakes when faulty in energised (closed) position
No brakes
81
What is connected to the emergency application valve
Hand and foot pilot valves
82
If defective EAV how must train be run?
Secondary circuit
83
Control gov bypass timer
30 seconds
84
Purpose of release prevention valve
Prevents release of auto air
85
What do we run on if release prevention valve not working
EP and rheo
86
How to ascertain BP not charging correctly due to regulating valve defect or BP leak?
Close bvic If BP drops then BP leak If doesn't drop then - EMY Open BVIC Release brake If it only charges back to previously low pressue then its regulating valve at wrong number
87
If BP is charging between 425kpa and 550kpa, what brake will we run on?
Ep and rheo and monitor BP
88
If BP not charging above 425, what will we need
A comp emp to charge BP from trailing motor
89
If brake handle releasing towards release positin what brake do we run on?
Air brake
90
What component of the brake unit is used to assist in preventing sticking brakes?
Dump valve
91
How will we know if we have sticking brakes
Wheel slip fault light Retardation of brakes Smoke/smell
92
LSM operation - all BVICS closed, speed is zero and timers have been reset (over 4 minutes) - What happens to pantos and MA'S?
All pantos will lower MA contacts will set to OFF
93
MR operating pressure
585-725
94
If MR tank ruptured why would you isolate the compressor governor?
To stop compressor running continuously
95
Train rescue - disabled train has electrical fault, will you couple up electrically?
No
96
Train rescue - when pushing disabled train out of section what will I need to do in my cab?
Red ec cock Raise trip Control gov bypass Set foot pilot valve Door loop bypass Isolate vicers
97
If coupling non electrically, what brake have you got?
Air
98
Saloon lights CB is located where?
Above door 3 in the saloon
99
Saloon light failure in regular sequence cause?
Circuit breaker has tripped
100
Saloon light failure in irregular sequence?
Tube is faulty/blown
101
If there is a saloon light failure, no emergency saloon lighting and its daylight, can you still run train?
Yes
102
Reasons for FDCL
Doors Control CB tripped BVIC
103
If FDCL not rectified, what do you do?
Door loop bypass
104
If 1 door is faulty is it likely caused by pneumatic, mechanical or electrical fault?
Mechanical
105
If all doors In 1 carriage faulty what is cause?
Pneumatic issue
106
If all doors on entire train faulty what is cause?
Auxiliary CB
107
If you have sticking brakes in running, what do you do?
Trip EP CB Make full service brake application
108
If sticking brake while stationary what do you do?
-Step 7 -> run and release multiple times (to flush out obstructing) -Release brake and go for power -If train rolls freely, can go back in service
109
Brake blocks - have deteriorated just past the 10mm line, is it still serviceable?
Yes
110
If metal backing on break is touching brake what do we do?
Isolate bogie
111
Piston travel mm's
30 - 65mm
112
If no continuous BP what is speed restriction?
15km
113
Brake handle defective in release position, what brake do we run on?
EP/Rheo