LCO 3.7 Flashcards
(20 cards)
3.7.1
Main Steam Safety Valves (MSSVs)
Bases?
Limits 2 MSSV to 110% of design by passing 100% flow
2 MSSV limiting event - full power loss of vacuum
1 MSSV limiting event - full power FWLB in CTMT
1 - 1250#
2 - 1290#
3,4,5 - 1315#
3.7.2
Main Steam Isolation Valves (MSIVs)
Modes?
MSIV Operability Requirements?
Actions?
Mode 1, Mode 2-4 (Except when all MSIVs Closed/Deactivated)
4 MSIVs AND Actuators
Isolation times in limited (<4.6 Sec?)
Close on MSIS
Fast Closure Available
Greater than or equal to 5000# Accumulator
Air Reservoir - Adequate Press (74# - Seis Alarm)
1 MSIV Actuator - 7 days 2 MSIV (1 ACT Inop/ Diff Trains) - 72 hrs 2 MSIV (1 ACT/ Same Train) - 48 hrs 1 MSIV (Both Act) - Declare MSIV INOP 3 Actuators - Declare MSIV INOP 1 MSIV INOP - Restore 4 hrs
3.7.3
Main Feedwater Isolation Valves (MFIVs)
Modes?
Requirements?
Actions?
Notes?
Mode 1-4 (Except when MFIV Closed/Deactivated OR Isolated by MOV)
4 Economizer MFWs and 4 Downcomer MFIVs
Separate Entry allowed for each penetration
Isolation times in Limits
Auto Close on MSIS
3.7.4
Atmospheric Dump Valves (ADVs)
Modes?
Requirements?
Bases?
Actions?
Modes 1-4 when S/Gs required for DHR
1 INOP on One/Both S/Gs - 7 Days
2 INOP on One/Both S/Gs - 24 hours
Bases:
C/D during SGTR
Remote OPS Required
13.3 hrs operations (4 hrs Mode 3/9.3 hrs to Mode 5)
3.7.5
Auxiliary Feedwater (AFW) System
3.7.6
Condensate Storage Tank (CST)
3.7.7
Essential Cooling Water (EW) System
Modes?
Actions?
Bases?
Component Isolation?
Modes 1-4 (72 hr LCO)
Mode 4 INOP- SDC INOP (3.0.6 N/A)
Cools CS for S/D and Loop
Cools Sump Fluid (LOCA)
Cools SDC (<350 F Tc to M5)
Isolate: SDC HX (Both SDC and EW INOP) Cross Tie to NC Priority Loads = EW INOP
3.7.8
Essential Spray Pond System (ESPS)
3.7.9
Ultimate Heat Sink (UHS)
3.7.10
Essential Chilled Water (EC) System
Modes?
Actions?
Component Isolation?
Modes 1-4 (72 Hr LCO)
Isolate One CLR - OK
Isolate greater or equal to 2 CLR - EC Operability depends on engineering evaluation
3.7.11
Control Room Essential Filtration System (CREFS)
3.7.12
Control Room Emergency Air Temperature Control System (CREATCS)
3.7.13
Engineered Safety Feature (ESF) Pump Room Exhaust Air Cleanup System (PREACS)
3.7.14
Fuel Storage Pool Water Level
3.7.15
Fuel Storage Pool Boron Concentration
3.7.16
Secondary Specific Activity
Modes?
Limit?
Bases?
Actions?
Mode 1-4 (Less than or equal to 0.1 mCi/gm Dose Equivalent I-131)
Mode 3 in 6 hours/ Mode 5 in 36 hours
Assumption in MSLB analysis
Small fraction of offsite dose limits (10 CFR 100)
3.7.17
Spent Fuel Assembly Storage
3.7.1
Main Steam Safety Valves (MSSVs)
Modes?
Requirements?
Actions?
Modes 1-3
Modes 1-2 = 10 per S/G Required (ALL)
Mode 3 = 2 per S/G Required
Modes 1-2
Up to 4 INOP per S/G - Reduce Power 4 hrs AND Reduce VOPT 36 hrs
>4 INOP per S/G - Mode 3 in 6 hours
> 8 per S/G INOP - Go to Mode 4
3.7.2
Main Steam Isolation Valves (MSIVs)
Bases (Safety Analysis)?
Limiting Accidents?
SLB in CTMT
Limiting Case - HZP (Most mass in S/G)
Loop/1 MSIV Fails Open
SLB in MSSS (Upstream MSIV)
Off-Site Dose Limiting (10CFR100)
SGTR
Limits Off-Site Dose
Isolates S/G for press control
Maintain SDM (Excessive C/D)
3.7.3
Main Feedwater Isolation Valves (MFIVs)
BASES? (Safety Analysis)
Large SLB/FWLB
Prevent water in steam lines (Hi Level)
Prevents excessive FW to Mo Minimize RCS Cooldown