What manufacturer is for mcf-09
Lyall
What size pipe is mcf-09 for
1-1/4 and 2”
What type of pipe is mcf-09 allowed to be installed on
PE
What is the allowed gap for 1-1/4 pipe
3-1/8 inch
What is the allowed gap for 2” pipe
3-7/8 inch
How many inches are required on either side of the point of assembly union mcf-09
19inches
What type of fitting is used in MCF-09
Repair coupling
You can only have the pull the long side out of 8100 or newer pipe. True or false
True
How far do we operate the pump for the long spigot side?
Until it aligns with the reference rib on the long spigot
The reference rib is Approximately 2” from the flange
How far do we operate the pump to complete the short spickot side?
Until it shoulders against the flange
What is the reference mark for left and right for 1-1/4
Left- 4-3/4inches
Right- 4-3/8inches
What is the reference mark for left and right for 2”
Left 4-5/8inches
Right 3-1/2inches