MK 16 EP's Flashcards Preview

1C > MK 16 EP's > Flashcards

Flashcards in MK 16 EP's Deck (19):
1

Alternating Red/Green Other than Transition: 2 Sensors 1.15 to 1.45, 3 sensor +1.45 or -1.15

Sensor out of limits, ensure at least 2 sensors within 1.15-1.45 ata, continue dive.

2

Alternating Red/Green Other than Transition: All 3 sensors 1.15 to 1.45

Low primary battery, Use secondary display to monitor, terminate dive

3

Flashing Green (other than descent) : 2 more 02 sensors +1.45

High 02PP, Monitor secondary, close 02, manually add 02 to maintain 1.15-1.45 terminate dive.

4

Flashing red (other than descent) : 2 or more sensors - than 1.15

Low 02, Water intrusion in the scrubber, Monitor both displays, manually add to maintain between 1.15-1.45, using highest pp02, terminate dive.

5

Flashing red (other than descent) : Low 02 PP, Low 02 bottle pressure

Monitor secondary, add diluent to maintain .16, breath open circuit, terminate dive.

6

No Primary display: Dropping secondary display readings

Primary Electronics Failure (PEA), Monitor Secondary, manually maintain 1.15-1.45, abort dive.

7

No Primary display: Stable secondary display readings

Primary Display/Cable Failure. Monitor Secondary, maintain 1.15-1.45, with 02 or diluent, abort dive.

8

No Primary display: Increasing secondary display readings

PEA Failure, Monitor secondary, close 02 bottle manually add to maintain 1.15-1.45, abort dive.

9

No Gas addition: 02 valve is depressed

02 bypass failed/bottle closed - empty, Monitor secondary, add diluent to maintain .16 ata switch to open circuit, abort.

10

No Gas addition: Diluent bypass failed, closed/empty

Monitor secondary, stay on closed circuit, abort

11

Continuous gas venting:Hear or feel gas escaping from MK16 02 leak

02/diluent bypass/addition failed or stuck open. MSD Close both bottles check indicators. 02 continues to drop keep closed open diluent manually drive adding 02 as required to maintain 1.15-1.45 abort dive.

12

Continuous gas venting:Hear or feel gas escaping from MK16 diluent leak

Diluent indicator drops leave closed, open 02, use diluent as needed fro volume makeup as required, abort dive.

13

Inhalation difficulty

Insufficient gas in breathing loop, MSD, add diluent until diaphragm vents on exhalation. continue dive.

14

Increased breathing resistance: gurgling/decreased buoyancy

Leak in recirculation system/pneumatics, Head up attitude, add diluent to force water out through dump, breathe open circuit, abort dive.

15

Complete rig flood out: water filled breathing loop

Leak in recirculation system/pneumatics, Head up attitude, add diluent to force water out through dump, breathe open circuit, abort dive.

16

No secondary display readings

SD blank fading, Monitor primary terminate dive

17

C02 buildup: Hypercapnia

C02 absorbent failure, add diluent to vent rig, breathe open circuit, abort dive.

18

Conflict between Primary and Secondary display: low or - secondary display with green primary.

Water intrusion into both scrubber and secondary cable, Monitor both displays, manually adding o2 using the highest ppo2, abort dive

19

UBA fails to switch from .75 to 1.3:Flashing green on primary display, sensor reading above .90

Failed hydrostatic switch, Monitor both Primary/Secondary abort dive.