OSHA Flashcards

(69 cards)

1
Q

The Prime Contractor Is Responsible

A

For Safety - 0.16

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Emergency Actions Plans For Companies With Fewer Than

Ten Persons

A

Need Not Be In Writing - .35(e)(3)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Common Drinking Cups Must Not Be Used

A

Not Be Used - .51(A)(4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

See Video For List Of Acceptable Types Of Chipping Goggles

A

102

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Does Employer Provide Protection?

A

Yes - .102(a)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Safety belt lanyard shall be ______ Nylon and withstand a Fall of No More Than ____ feet, breaking point ______ Lb.

A

1/2”, 6, 5400 - .104(d)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

List Class B fire extingusher types -

A

Foam, Carbon Dioxide, Chemical - .150, TABLE F-1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A Fire Extinguisher not rated less than______Per _____ Sf of building area.

A

2A, 3000 - .150(c)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

No more than ______ Gallons Of Flammable Liquids May Be Stored in a room Outside Of
Approved Storage Cabinets

A

25 - .152 b

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Access Way ______Wide To Within ______ Feet Of Storage Containers

A

12’, 200, - .152 c (2)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Every container / vaporizor safety valve shall discharge not less than _____horizontally away from any opening to the building

A

5 feet - .153(d)(1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Distance That Flammable Materials May Be Stored Away

From Liquified Petroleum Gas

A

0, 10,20,25 - .153(k) TABLE F-3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Flammable Materials Distance From Heating Device

A

.154(b)(2) TABLE F-4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Heating Devices At Least _______Away From Tarpaulins

A

Ten feet - .154(b)(4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Materials stored in a building shall be At Least ______From Exterior Wall

A

Ten Feet - .250(b)(1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Bagged materials shall _______ layers and cross key at least every ____ Bags High

A

step back, Ten - .250(b)(4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Brick Stacks shall not be more than____ high, Loose brick tapered ______for every foot over 4 feet.

A

7’, 2 inches - .250(b)(6)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Masonry Block stacked over _____feet shall be taperd ______ per tier.

A

Six, 1/2 block .250(b)(7)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Lumber Stack Heights, not to exceed _______, no more than _____ if handled manually

A

20 feet, 16 feet - .250(b)(8)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Wire Rope Shall Not Be Used When More Than _____Of The Strands Have Been Damaged Within A Length Of ______.

A

10% , 8 Diameters - .251(c)(4)(iv)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Chute Required When Dropping Debris More Than ______Feet.

A

20 - .252(a)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

When Debris Is Dropped Thru Holes In Floors, A _____ High Barricade _______Outside The Hole Must Be Installed Around The Drop Zone On The Lower Floor.

A

42”, 6” .252(b)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Skill Saws Are Required To Have ___________ Guards

A

“Point Of Operation” - .300(b)(4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Compressed Air Used For Cleaning Purposes Shall Not Exceed ?

A

30 Psi - .302(b)(4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Abrasion Wheel safety measures
Sufficient power, Safety guards, spindle end, nut and flange protection - 0.303
26
Gas Storage Requirements…....Gas Welding and cutting - Know the section
.350(a) & (d)
27
Welders Working In Confined Spaces…. 3 Requirements
Ventilation, Respirator, Safety line - .353(b)
28
Scaffolds Must Support At Least ______ The Intended Weight
Four Times - .451(a)(1)
29
Minimum With Of Scaffold Platforms Is
18" - .451(b)(2)
30
Maximum Distance From Outrigger Scaffold Platform To | Face Of Building Is
3" - .451 (b)(3)(i)
31
Maximum Distance From Scaffold To Face Of Building When Applying Stucco Is
18" - .451(b)(3)(ii)
32
Each End Of A Scaffold Must Extend ____ Past The Scaffold Support
6" - .451(b)(4)
33
Scaffold Anchor Spacing
20 feet, not more than 30 feet - .451(c)(1)
34
Scaffolds Erected Under Supervision Of
A Competent Person - .451(f)(7)
35
Scaffold Handrail Height Between ______ And _______Above Scaffold Platform
36", 45" - .451(g)(4)(ii)
36
Scaffold Wire Rope Shall Be ______ And Without ________ Between Anchors
Continuous, Splices - .452(r)(4)
37
Guardrails Are Required When Working More Than ________ High
6' Feet - .501(b)(2)
38
Guardrails Are Required When Excavation Is Deeper Than _______ Feet
6 - .501(b)(7)
39
Structurall systems to support _______ Pounds
200 - .502(b)(3)
40
A Lanyard Should Be Connected At __________ Of The Wearers Back
The Center Point - .502(d)(17)
41
Covers Must Support _______ The Intended Weight
Twice - .502(i)(2)
42
Control linse must be located not less than _____feet nor more than _____feet from unprotected edge
6, 25 - .502(G)(1)(i)
43
Rubber Tired Heavy Equipment Requires Fender if travelling more than_______ MPH
15 - .602(5)
44
Clearing Equipment Rollover Canopy_____Thick, wire mesh nor than ____ inch
1/8", 1/4" - .604(a)(2)(i)
45
What is a Kickout?
Anaccidental release or failure of a cross brace - .650(b)
46
In Excavations More That _____ Deep ladders are located _____ apart.
4 Feet, 50 feet - .651(c)(2)
47
Air Quality Must Be Tested In Excavations
Prior To Beginning Work - .651 (g)(1)(i)
48
Minimum Percent Oxygen Is _____, Maximum ______
19.5%, 23.5% - .651(g)(1)(iii)
49
Materials Stored At Least ______ From The Edge Of An Excavation
2 feet - .651 (j)(2)
50
Who Inspects Excavations On a Regular Basis?
Competent Person - .651(k)
51
A Handrail Is Required For Walkways Over Trenches More Than ______ Deep
6 Feet - .651(i)
52
Employees Must Be Protected From Cave-Ins When Excavation More Than
5' Deep - .652(a)(1)(ii)
53
Excavations May Be ______ Below Trench Box
Two Feet - .652(g)(2)
54
Unconfined Compressive Strength, What are two filed tests?
Pocket Petrometer, Thumb Penetration - Appendix A to Subpart P
55
Maximum Allowable Slopes….. Know this table
Appendix B to Subpart P, TABLE B-1
56
How shall Formwork be designed?
To withstand verticle or lateral loads - .703(a)
57
Masonry Wall Over High Shall Be Braced
8 Feet - .706(b)
58
Persons ____________ Of Loads May Work Under Loads
Responsible For The Hooking - .753(d)(1)(ii)
59
Structural Steel Assembly Of Multistory Building
Perminant floors installed as structure progresses.754(b)
60
Solid Floors No More Than ______ Below Steel Erectors
30 feet - .754(b)(3)
61
When Debris Is Dropped Thru Holes In Floors, A ____High Barricade______Outside The Hole Must Be Installed Around The Drop Zone On The Lower Floor.
42", 6 Feet - 850(h)
62
A Change In Elevation Of _______Requires A Ladder Or Stairs
19" - .1051A
63
At Least______Handrail On Enclosed Stairs
One - .1052(c)(1)(i)
64
When Accessing A Roof With A Ladder, The Ladder Must Extend _____Above The Roof
3 Feet - .1053(b)(1)
65
Ladders Should Slope So That The Distance From The Base Of The Ladder To The Base Of The Building Is Equal To The Working Length Of The Ladder
1/4 - .1053(b)(5)(i)
66
The Atmosphere In Confined Spaces Must Be Tested For __________ Prior To Persons Entering.
Oxygen, Flammable Gases, And Toxic Air Contaminants - .1203(e)(2)(iii)
67
The Distance From A Crane Boom And A Power Line Rated Less Than 50Kv Must Be At Least?
10 Feet - .1408(h) Table A
68
A Crane Must Be Inspected By ________ Prior To Each Shift
A Competent Person - .1412(d)(1)
69
Employers must use assigned protection factors listed in table______ that meet or exceed requirements
Table 1 - 1910.134(d)(3)(i)(A)