Part III Flashcards
(91 cards)
3 Parts of MRI Suites
Gantry
Control Console
Computer Network/System
Operating console is composed of :
-imaging acquisition
-image processing
Operating console [added]
Start-up
Image acquisition
Prescan Calibrators
Image Scanning
Image Processing/Display/Manipulation
MRI computers is composed of:
Multitasking operating system
Control Computer
Acquisition Control System
Image Reconstruction
Processing Computer
MRI system electronics
Frequency Synthesizer
RF Amplifier
Gradient Coil Power Supply
Sequencing System
Digital Signal Acquisition System
Digital Image Processing System
Ancillary Equipment
Power Injectors
Infusion Pumps
Pads and Pillows
Cryogenic Filling Equipment
CM used in MRI
Gd DPTA -contrast (paramagnetic)
Diethylenetriamine Penta-acetic acid
[ancillary equip.] Facilitate introduction of CM, Nonmagnetic
Power injectors
[ancillary equip.] Used for introduction of saline/fluid, automatic set rate/amount
Infusion Pumps
[ancillary equip.] used for pt comfort, headphones, pillows, blankets
Pads and pillows
[ancillary equip.] cooling system used to ensure magnetic property
Cryogenic filling equipment
[operating console-start- up] energizes the system
Power On/Off
[operating console-start- up] should be used if the pt is in danger (in case of adverse fx, claustrophobic)
Emergency Off
[operating console-start- up] installed with TV system for communication
Intercom - speaker and Tv monitor to ensure pt is not moving
[operating console-start- up] selection of pulse sequence, pulse delay timings, other parameters
Scan Control Module
[operating console-start- up] SLICES (no of gaps); scout images
Image-Guided Graphical Prescription
[operating console-start- up] review the image (display windowing), parametric imaging processing
Image Display System
[operating console] involves stimulation of H and receiving of signal
Image Acquisition
[operating console-image acquisition] often automatic, accommodate the body part/FOV
Tuning Control
[operating console-image acquisition] RT can modify, 90-90deg..90-180deg/..
Pulse Sequence Selection
[operating console-image acquisition] selection of repetion time [TR] and echo time [TE]
Timing selection
[operating console-image acquisition] optimize image contrast and SNR (reduce artifacts)
X and y axis to get FID
RF pulse flip angle selection
[operating console-image acquisition] Matrix Size
256x256; larger matrix size = better image, longer imaging time
[operating console-image acquisition] FOV
reduced FOV = better spatial resolution (requires more signal acquisition)