Part III Flashcards

(91 cards)

1
Q

3 Parts of MRI Suites

A

Gantry
Control Console
Computer Network/System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Operating console is composed of :

A

-imaging acquisition
-image processing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Operating console [added]

A

Start-up
Image acquisition
Prescan Calibrators
Image Scanning
Image Processing/Display/Manipulation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

MRI computers is composed of:

A

Multitasking operating system
Control Computer
Acquisition Control System
Image Reconstruction
Processing Computer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

MRI system electronics

A

Frequency Synthesizer
RF Amplifier
Gradient Coil Power Supply
Sequencing System
Digital Signal Acquisition System
Digital Image Processing System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Ancillary Equipment

A

Power Injectors
Infusion Pumps
Pads and Pillows
Cryogenic Filling Equipment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

CM used in MRI

A

Gd DPTA -contrast (paramagnetic)
Diethylenetriamine Penta-acetic acid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

[ancillary equip.] Facilitate introduction of CM, Nonmagnetic

A

Power injectors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

[ancillary equip.] Used for introduction of saline/fluid, automatic set rate/amount

A

Infusion Pumps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

[ancillary equip.] used for pt comfort, headphones, pillows, blankets

A

Pads and pillows

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

[ancillary equip.] cooling system used to ensure magnetic property

A

Cryogenic filling equipment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

[operating console-start- up] energizes the system

A

Power On/Off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

[operating console-start- up] should be used if the pt is in danger (in case of adverse fx, claustrophobic)

A

Emergency Off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

[operating console-start- up] installed with TV system for communication

A

Intercom - speaker and Tv monitor to ensure pt is not moving

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

[operating console-start- up] selection of pulse sequence, pulse delay timings, other parameters

A

Scan Control Module

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

[operating console-start- up] SLICES (no of gaps); scout images

A

Image-Guided Graphical Prescription

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

[operating console-start- up] review the image (display windowing), parametric imaging processing

A

Image Display System

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

[operating console] involves stimulation of H and receiving of signal

A

Image Acquisition

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

[operating console-image acquisition] often automatic, accommodate the body part/FOV

A

Tuning Control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

[operating console-image acquisition] RT can modify, 90-90deg..90-180deg/..

A

Pulse Sequence Selection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

[operating console-image acquisition] selection of repetion time [TR] and echo time [TE]

A

Timing selection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

[operating console-image acquisition] optimize image contrast and SNR (reduce artifacts)
X and y axis to get FID

A

RF pulse flip angle selection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

[operating console-image acquisition] Matrix Size

A

256x256; larger matrix size = better image, longer imaging time

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

[operating console-image acquisition] FOV

A

reduced FOV = better spatial resolution (requires more signal acquisition)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
[operating console-image acquisition] amount of FID needed
Number of Signal Acquisitions (NSA) Number of Excitations (NEX) Number of Averages (NA)
26
[operating console-image acquisition] Slice Thickness
Reduced slice thickness improves spatial resolution Thicker slice = < detail
27
[operating console-image acquisition] affects the SNR and chemical shift artifact Range of frequency/signals
Receiver Bandwidth (BW)
28
[operating console-image acquisition] pre saturation pulses to eliminate signals from certain samples (fats and water)
Magnetization Preparation Schemes
29
[operating console-image acquisition] 2D and 3D images, usually for advanced imaging system - possible in MRI arteriogram
Reconstruction Strategies
30
[operating console-image acquisition] number. Of slices, gaps b/w slices, orientations - sagittal , coronal, axial
Slice Positioning and Orientation
31
[operating console] role of computer system
Prescan Calibrators
32
[operating console-prescan calibrators] accommodate the patient’s size - adjust RF coil to match patient habitus
Transmit/Receive Coil Tuning
33
[operating console-prescan calibrators] establishes the slice position and resonance frequency of fats and water photons (automatic)
Center Frequency Tuning
34
[operating console-prescan calibrators] sets the duration that radio frequency is on and the amount of power to generate the radio frequency (if short-blurry)
Pulse Amplitude Calibration
35
[operating console-prescan calibrators] ensures that signal is not too low (noisy image) or too high (image distortion)
Receiver Gain Control
36
[operating console-prescan calibrators] makes the MF homogenous
Autoshimming
37
Importance of Magnetic Shimming
-maintain homogenousfield -minimize fringe field-stray field that can interfere with electronic devices
38
Magnet ensure safety within [..]
5G
39
Protect the magnet from outside things that can affect the homogenous MF
Shimming
40
Protect public and environment
Fringe field
41
Two types of magnetic shielding
Passive - walls of MRI gantry (s), MRI suite (f) Active - magnet in gantry
42
[operating console-Imaging Scanning] Patient Positioning
Uses: surface coils/phased array coils Laser positioning system
43
Surface coil purpose:
Added on POI, receive only Shorten distance -enhance contrast
44
[operating console-Imaging Scanning] Patient Monitoring
Uses TV and intercom
45
[operating console-Imaging Scanning]inspect date for quality and positioning of data
Image Quality Inspection
46
[operating console] Imaging Scanning
Pt Positioning Pt Monitoring Image Quality Inspection
47
[operating console-Image Processing/Display/Manipulation] set the contrast and shades of gray. Wider range in MRI
Window Width Level
48
[operating console-Imaging processing/ display/ manipulation] pointer
Cursor On/Off
49
[operating console-Imaging Processing] calculation of area of measure and average and standard deviation of pixel values
Region of Interest (ROI)
50
[operating console-Imaging processing] magnify the image. Some may produce fixed magnification. Reconstructive [..] is not possible in MRI
Zoom
51
[operating console-Image Processing] selects pixel values within a given range for special attention
Highlight
52
[operating console-Imaging Scanning] simultaneous display of multiple images or portions of an image on one wide screen
Display Matrix Format
53
[operating console-image processing/display manipulation] plotting of pixel values along the identified axis in a line graph
Profile/ Histogram
54
[operating console-image processing/display manipulation] selects pixel values within a given range for special attention
Highlight
55
[operating console-image processing/display manipulation] simultaneous display of multiple images or portions of an image on one wide screen
Display Matrix Format
56
types of computer system
-control computer -acquisition control computers -image processing computer
57
control computer provides an interface with the operator for:
control and display functions data archiving and network communications
58
[computer system] computer that control the gantry, receive instructions from control computers -converts instructions to specific pulses, timing delays and amplifier gain
acquisition control computers
59
location of acquisition control computer
equipment room
60
[computer system] for image reconstruction
image processing computer
61
[computer system] should have high capacity to store data for manipulation; fast to handle the high rate of data acquisition; can accommodate enormous no. of calculations
image processing computer
62
image processing time: [..]
1 sec - to entertain more frames
63
additional subsystems to assist in the functioning of computers
MRI System Electronics
64
[MRI System Electronics] produce RF pulse, generates the fundamental resonance frequency used to excite the magnetic nuclear spins
Frequency Synthesizer
65
[MRI System Electronics] produces low-level sinusoidal wave signal from a fixed time base oscillator [high intensity = low RF frequencu
Frequency Synthesizer
66
types of RF Synthesizer
direct digital synthesizer (DDS) dividing time
67
[RF Synthesizer] creates arbitrary waveforms using frequency and pulse-tunable output signals
direct digital synthesizer (DDS)
68
[RF Synthesizer] fixed frequency precision clock source referenced to DDS
MRI System Clock
69
[MRI System Electronics] the DDS scales the frequency clock using a programmable binary tuning word that is typically [...] long
Dividing Time 24-48 bits
70
[MRI System Electronics] increase signal out put from the frequency synthesizer; should be immune to load changes
Radiofrequency Amplifier
71
RF energy is [..] to RF frequncy
directly proportional
72
T/F MRI amplifiers must have an increasing power ratings when used with higher field magnets
T
73
RF AMPLIFIER : 1.5 T maximum outputs
18 kW -25 kW
74
RF AMPLIFIER : 3 T maximum outputs
30 kW - 40 kW
75
[MRI System Electronics] operates in a current-driven mode; installed with cooling system to ensure stability of temperature
Gradient Coil Power Supply
76
Gradient Coil Power Supply : peak output current can range up to [..] and peak voltages up to [..]
1 kA 500 V
77
high powered GPS for the whole body categories
-Linear GPS - Switching GPS System and Resonant System -Pre-emphasis circuitry module
78
[GPS] deliver power directly to the coils
linear GPS
79
[GPS] uses energy storage strategies to reduce power dissipation [backup power]
Switching GPS System and Resonant System
80
[GPS] modifies the gradient pulse waveform to minimize EDDY CURRENT
Pre-emphasis circuitry module
81
result of current opposing the cause that produced them, produced in any conducting material subjected to changing MFs
EDDY CURRENT
82
[MRI System Electronics] inorder to accept current, magnetic coils must have resistance
Magnetic Power Supply
83
[MPS]
persistent switch magnetic power supply stabilized Bo Field
84
[MPS} superconducting heat switch may be used - help in giving current
Persistent Switch
85
programmed to slowly inject current until the specific MF had been attained
Magnet power supply
86
[MPS] the current to the switch is turned off
Stabilized Bo field
87
[MRI System Electronics] traffic cop of MRI Scanner that takes instruction from the computer and setting up proper parameters; controls the RF transmitter and gradient amplifiers to cause an MR image
Sequence System (Pulse Programmer)
88
[MRI System Electronics] sets parameters such as bandwidth for the subsystem receiver
Sequence System (Pulse Programmer)
89
[MRI System Electronics] signals (from H atoms) -receiver - preamplifiers
Digital Signal Acquisition System
90
increase the amplitude of MRI signal from tens to hundreds of mV to several Volts
Pre Amplifiers
91
[MRI System Electronics] Digital Image Processing System includes:
GENERAL PURPOSE MICROPROCESSOR FIELD PROGRAMMABLE GATE ARRAYS (FDGAS) Digital Signal Controllers Stream Processor