PLUMBING CODE II Flashcards

(105 cards)

1
Q

Consists of a body, a checking member, and an atmospheric opening.

A

Atmospheric Vacuum Breaker (AVB)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

consists of 2 independently acting internally or externally loaded check valves, 4 properly located test cocks with connectors, and 2 isolation gate valves

A

Double Check Valve Backflow Prevention Assembly (DC)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

consists of a loaded air inlet valve, an internally loaded check valve, 2 properly located test cocks, and 2 isolation gate valves.

A

Pressure Vacuum Breaker Backflow Prevention Assembly (PVB)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

consists of 2 independently acting internally loaded check valves, “a differential pressure relief valve”, 4 properly located test cocks, and 2 isolation gate valves.

A

Reduced Pressure Principle Backflow Prevention Assembly (RP)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Hanger rod size for 5” pipe size

A

Correct answer: 13 mm (or 1/2”)
Source: Uniform Plumbing Code

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Hanger rod size for 1/2” to 4” pipe

A

3/8” rod size

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Hanger rod size for 5” to 8” pipe

A

1/2” rod size (12.70mm)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Hanger rod size 10” to 12” pipe

A

5/8” rod size (15.88 mm)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

An additional cleanout shall be provided on a horizontal line with an aggregate offset angle of direction exceeding _____.

A

Correct answer: 135°
Source: RNPCP, Chapter 6

Additional info:
Cleanouts may be omitted on short horizontal drainage pipe installed at 72° or less from the vertical line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

AVBs of inlets to tanks, vats, sumps shall be installed in the discharge side of the _____ with the critical level not less than _____ above flood level rim.

A

Correct answer: last valve; 152 mm
Source: RNPCP, Chapter 6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Every building where _____ shall have a sewer service connection to a public or private sewer systems.

A

Correct answer: plumbing fixtures are installed
Source: RNPCP, Chapter 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A standpipe having a remote control device at each hose station.

A

Correct answer: Manually-Operated Standpipe System
Source: RNPCP, Chapter 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Each tailpiece, continuous waste or waste and overflow shall not be less than ___ for sinks, dishwashers, laundry tubs bathtubs, urinals and similar fixtures.

A

Correct answer: 38 mm O.D.
Source: RNPCP, Chapter 4

Additional info:
- 32 mm O.D.- for lavatories, drinking fountains, and similar small fixtures

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Trap arm size of a service sink

A

Correct answer: 51 mm
Source: RNPCP, Chapter 7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

trap arm size for bathtubs, bidet, etc.

A

38 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

trap arm size for sand interceptors, flushing rim sink clinic, etc.

A

76 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

trap arm size of a dental unit or cuspidor

A

32 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

A run of 20 meters with a rise of 0.5 m corresponds to a slope of _____.

A

2.5%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

A device installed in a drainage system to prevent reverse flow.

A

Correct answer: Backwater Valve
Source: RNPCP, Chapter 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

a valve that automatically closes to prevent the flow of liquid or gas in a reverse direction

A

Check Valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

a valve opened and closed by the fall and rise of an attached ball floating on the surface of the liquid.

A

Ball Cock

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

receives sewage or wastewater and below the normal grade of the gravity system

A

Sump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

What is the allowed depth of shower dam or threshold?

A

Correct answer: 2”-9”
Source: RNPCP, Chapter 4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Threads per inch of a 64 mm cleanout size

A

Correct answer: 8 Threads per inch (TPI)
Source: RNPCP, Chapter 7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Threads per inch of a 38 to 51 mm cleanout size
11-1/2 Threads per Inch (TPI)
26
The discharge capacity of 1 to 1.89 lps corresponds to _____.
Correct answer: 4 FU Source: RNPCP, Chapter 7
27
Clothes washers in groups of 3 or more shall be rated at _____ each for the common horizontal and vertical waste pipe sizing.
Correct answer: 6 FU Source: RNPCP, Chapter 7
28
The public sewer may be considered not being available when a sewer is located more than _____ from any proposed building or exterior drainage facility.
Correct answer: 61 m Source: RNPCP, Chapter 12
29
maximum distance between manholes
91 m
30
A fixture allowed to omit a cleanout on a horizontal line less than 1.5 m in length is _____.
Correct answer: Bathtub Source: RNPCP, Chapter 7
31
Cleanouts may be omitted on a horizontal drain line less than 1.5 m in length unless such line is serving _______.
sinks or urinals
32
What is the maximum fixture loading of a 8" pipe sloped at 1%?
Correct answer: 2112 Source: RNPCP, Chapter 7 Additional info: For 1% slope, multiply horizontal fixture units by a factor of 0.8.
33
Preferred pipe for transporting gas
Correct answer: Black Steel Pipe Source: hu-steel.com; buyfittingsonline.com; not suitable for water because it tends to erode more easily
34
suitable for water supply in old houses
Galvanized Pipe
35
suitable for sanitary, storm sewers, and culverts
Concrete pipe
36
suitable for drainage
Cast Iron Soil Pipe
37
1 Kcal is how many BTU?
Correct answer: 3.965 (standard conversion) Additional info: - 1 Kcal = 4184 Joule - 1 Kcal = 4.184 KJoule
38
Vertical installation of double sanitary tees may be used when the barrel of the fitting is at least _____ larger than the _____ inlet.
Correct answer: 2 pipe sizes; largest side inlet Source: RNPCP, Chapter 3
39
The transference of heat by the upward movement of a warm light air current.
Correct answer: Convection Source: Audel
40
the process in which energy in the form of heat is sent through space from atoms and molecules as they undergo internal change.
Radiation
41
the transference of heat by the passage of energy, particle by particle.
Conduction
42
the process by which a solid holds molecules of a gas or liquid or solute as a thin film.
Adsorption
43
What will happen if a drainage piping is placed at slope of 10mm/m due to structural conditions?
Correct answer: Decrease in DFU loading Source: RNPCP, Chapter 7 Additional info: - 1% slope will require lesser DFU loading - If using 1% or 10mm/m slope, multiply the allowable DFU of horizontal drain stated in Table 7-5 by a factor of 0.8 - drainage slope does not affect length
44
Which of the following can be drained through an air break?
Correct answer: evaporative cooler Source: RNPCP, Chapter 8 Additional info: - all food equipment such as cold storage room, refrigerator, cooling counter, compartment for storage or holding of food or drink, dishwashing or culinary sink must discharge through an airgap
45
Joints for hubless cast iron soil pipe and fittings shall conform to appropriate _____ installation standards.
Correct answer: IAPMO (International Association of Plumbing & Mechanical Officials) Source: RNPCP, Chapter 13
46
Medical gas piping is most often joined by _____.
Correct answer: silver brazing Source: plumbinghelp.com
47
a process in which two or more items are joined by melting and putting a filler metal (solder) into the joint
Soldering
48
A mechanical connection which depends on an internal retention device to prevent pipe or tubing separation
Pressure-lock type
49
common joint for PPR (Polypropylene Random Copolymer)
Heat fusion
50
Copper tubing shall be fully externally protected with a/an _____ and fiberglass wrapping installed inside a split rigid casing whenever installed underground.
Correct answer: bitumastic coating Source: RNPCP, Chapter 6
51
protection from breakage for piping passing under or through walls
Embedded metal pipe sleeves
52
protection from external corrosion for pipes passing through or under cinders or other corrosive materials
Polyethylene sheath
53
for voids between pipes and sleeves through concrete floors in the ground
Bitumen
54
for pipes directly embedded in concrete and masonry walls
Metal sleeve
55
Limit stops shall be adjusted to deliver hot water with a maximum temperature of _____.
Correct answer: 120°F (or 48.88 °C) Source: RNPCP, Chapter 4
56
Operating temperature of a backflow prevention for hot water
43.3°C (or 110°F)
57
How many fixture units is equivalent to a 30 gpm-rated sump?
Correct answer: 60 FU Source: RNPCP, Chapter 7; Uniform Plumbing Code, Chapter 7 Additional info: - Two FU shall be allowed for every 0.063 L/s of flow, or 1 gpm.
58
1 Laundry Tray must be provided per ____ persons.
Correct answer: 50 Source: RNPCP, Chapter 4
59
Galvanized wrought iron or galvanized steel pipe shall be kept _____.
Correct answer: 150 mm above ground Source: RNPCP, Chapter 9
60
pipes must be kept 300 mm below ground
Vitrified clay
61
A double check valve backflow preventer requires _____ minimum clearance at the bottom for maintenance.
Correct answer: 305 mm Source: RNPCP, Chapter 6
62
Airgap less than 25 mm shall only be approved as a permanent part of a listed assembly that has been tested under actual backflow conditions with vacuums from _____ of mercury.
Correct answer: 0 to 63.5 cm Source: RNPCP, Chapter 6
63
What is the Maximum DFU loading of a 102 mm branch?
Correct answer: 216 (for Branch or Horizontal Pipe) Source: RNPCP, Chapter 7
64
Maximum DFU loading for 102 mm Stack (or vertical pipe)
256
65
Maximum DFU loading for 600 mm Stack (or vertical pipe)
600
66
Maximum DFU loading for 152 mm Stack (or vertical pipe)
1380
67
Water Closet provision for 300 females in Assembly Places for Public Use
Correct answer: 11 Source: RNPCP, Chapter 4
68
Thickness of Continuous waste and fixture tailpiece- seamless drawn brass
Correct answer: Gauge 20 (0.8 mm) Source: RNPCP, Chapter 4
69
Thickness of copper pans or liners for shower subpans
Gauge 24 (0.5 mm)
70
thickness of restaurant kitchen and other special-use sinks, bonderized and galvanized sheet steel
Gauge 16 (1.6 mm)
71
thickness of galvanized sheet metal for downspout or conductor
Gauge 26 (0.47mm)
72
Backflow prevention device for a hose bibb
Correct answer: Atmospheric Vacuum Breaker (AVB)- consists of a body, a checking member, and an atmospheric opening Source: RNPCP, Chapter 6
73
WSFU of a private hose bibb
Correct answer: 3: WSFU of Public Hose Bibb or Sill Cock Source: RNPCP, Chapter 6
74
WSFU of Public Hose Bibb or Sill Cock
5
75
WSFU of Water Closet (economical flush)
2.5
76
WSFU of Urinal pedestal, flushing rim sink
10
77
Linings for showers shall not be nailed or perforated at any point less than _____ above the finished dam or threshold.
Correct answer: 1" or 25.4 mm Source: RNPCP, Chapter 4
78
dimension that refers to extension of lining materials above the top of the finished dam or threshold of a shower
76 mm (or 3")
79
dimension that refers to extension of folds, laps, and reinforcing webbing in all directions from the corner in a shower sub-pan
101 mm (or 4")
80
A _____ diameter circular basin shall be equivalent to 1 lavatory.
Correct answer: 457.2 mm Source: RNPCP, Chapter 4
81
refers to the width of a circular basin that shall be considered equivalent to 1 lavatory
609.6 mm
82
What is the minimum supply size for a urinal stall?
Correct answer: 19 mm Source: Annex A
83
All reinforcing webbing shall produce a tensile strength of not less than _____ in either direction.
Correct answer: 0.9 kg/mm Source: RNPCP, Chapter 4
84
Color of Steam Division- High Pressure Pipe
Correct answer: White Source: National Building Code Rule X (Old NBC) Additional info: - Amended NBC has a different color for High Pressure Steam (Yellow). The answer might depend on the choices given. Most probably, the examiner will base on the old NBC since the questions are included in a Question Bank.
85
Color of Steam Division- Exhaust System
Buff
86
Each pressure relief valve shall be an approved automatic type with drain and set at a pressure not more than _____.
Correct answer: 1033 kpa (or 150 psi) Source: RNPCP, Chapter 6
87
Threads per inch for pipe size of 13 mm diameter.
Correct answer: 14 Threads per Inch (TPI) Source: engineeringtoolbox.com
88
Threads per inch for Pipe size of 1/4" to 3/8" ( 6.35mm to 9.525mm)
18 Threads per Inch (TPI)
89
Threads per inch for Pipe size of 1" to 2" (25.4mm to 50.8mm)
11-1/2 Threads per Inch (TPI)
90
Threads per inch for Pipe size of 2-1/2" and above (63.5mm and above)
8 Threads per Inch (TPI)
91
Potable water shall use solders and fluxes with a lead content not exceeding _____.
Correct answer: 0.2% Source: RNPCP, Chapter 13
92
"maximum lead content allowed" in water pipes and fittings
8%
93
A pressure regulator must be installed if the local water service pressure is above ____
Correct answer: 80 psi (or 551 kpa) Source: RNPCP, Chapter 7
94
this refers to the minimum water pressure, otherwise a tank or a booster pump must be installed
103 kpa (or 15 psi)
95
Trap arm size of Laundry Tub
Correct answer: 38 mm Source: RNPCP, Chapter 7
96
trap arm size of wash basin (lavatory) single, dental units or cuspidor
32 mm
97
trap arm size of floor drains, grease interceptors, showers, etc.
51 mm
98
trap arm size of water closet
76 mm
99
Water pipe joints shall be installed not less than ___ away from sewer line in both directions.
Correct: 3 m Source: RNPCP, Chapter 12
100
Changes in direction of drainage piping shall be made by the use of approved pipe fittings like the following, except for _____.
Correct answer: 90 degrees Source: RNPCP, Chapter 3
101
Voids between pipes and sleeves through concrete floors in the ground shall be appropriately sealed with _____.
Correct answer: Bitumen Source: RNPCP, Chapter 3
102
protection from breakage for piping passing under or through walls
Embedded metal pipe sleeves
103
protection from external corrosion for pipes passing through or under cinders or other corrosive materials
Polyethylene sheath
104
for voids between pipes and sleeves through concrete floors in the ground
Bitumen
105
for pipes directly embedded in concrete and masonry walls
Metal sleeve