PLUMBING CODE II Flashcards
(105 cards)
Consists of a body, a checking member, and an atmospheric opening.
Atmospheric Vacuum Breaker (AVB)
consists of 2 independently acting internally or externally loaded check valves, 4 properly located test cocks with connectors, and 2 isolation gate valves
Double Check Valve Backflow Prevention Assembly (DC)
consists of a loaded air inlet valve, an internally loaded check valve, 2 properly located test cocks, and 2 isolation gate valves.
Pressure Vacuum Breaker Backflow Prevention Assembly (PVB)
consists of 2 independently acting internally loaded check valves, “a differential pressure relief valve”, 4 properly located test cocks, and 2 isolation gate valves.
Reduced Pressure Principle Backflow Prevention Assembly (RP)
Hanger rod size for 5” pipe size
Correct answer: 13 mm (or 1/2”)
Source: Uniform Plumbing Code
Hanger rod size for 1/2” to 4” pipe
3/8” rod size
Hanger rod size for 5” to 8” pipe
1/2” rod size (12.70mm)
Hanger rod size 10” to 12” pipe
5/8” rod size (15.88 mm)
An additional cleanout shall be provided on a horizontal line with an aggregate offset angle of direction exceeding _____.
Correct answer: 135°
Source: RNPCP, Chapter 6
Additional info:
Cleanouts may be omitted on short horizontal drainage pipe installed at 72° or less from the vertical line
AVBs of inlets to tanks, vats, sumps shall be installed in the discharge side of the _____ with the critical level not less than _____ above flood level rim.
Correct answer: last valve; 152 mm
Source: RNPCP, Chapter 6
Every building where _____ shall have a sewer service connection to a public or private sewer systems.
Correct answer: plumbing fixtures are installed
Source: RNPCP, Chapter 3
A standpipe having a remote control device at each hose station.
Correct answer: Manually-Operated Standpipe System
Source: RNPCP, Chapter 2
Each tailpiece, continuous waste or waste and overflow shall not be less than ___ for sinks, dishwashers, laundry tubs bathtubs, urinals and similar fixtures.
Correct answer: 38 mm O.D.
Source: RNPCP, Chapter 4
Additional info:
- 32 mm O.D.- for lavatories, drinking fountains, and similar small fixtures
Trap arm size of a service sink
Correct answer: 51 mm
Source: RNPCP, Chapter 7
trap arm size for bathtubs, bidet, etc.
38 mm
trap arm size for sand interceptors, flushing rim sink clinic, etc.
76 mm
trap arm size of a dental unit or cuspidor
32 mm
A run of 20 meters with a rise of 0.5 m corresponds to a slope of _____.
2.5%
A device installed in a drainage system to prevent reverse flow.
Correct answer: Backwater Valve
Source: RNPCP, Chapter 2
a valve that automatically closes to prevent the flow of liquid or gas in a reverse direction
Check Valve
a valve opened and closed by the fall and rise of an attached ball floating on the surface of the liquid.
Ball Cock
receives sewage or wastewater and below the normal grade of the gravity system
Sump
What is the allowed depth of shower dam or threshold?
Correct answer: 2”-9”
Source: RNPCP, Chapter 4
Threads per inch of a 64 mm cleanout size
Correct answer: 8 Threads per inch (TPI)
Source: RNPCP, Chapter 7