Power Distribution Systems (obj 2.4) Flashcards

(13 cards)

1
Q

What is the purpose of Power Distribution Systems?

A

Crucial for consistent and reliable power delivery

Power Distribution Systems ensure that electricity is efficiently and reliably delivered to various components within a facility.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What does an Uninterruptible Power Supply (UPS) provide?

A

Emergency power during main power failures, surge protection, and line conditioning

A UPS typically lasts between 15 to 30 minutes and is essential for maintaining operations during power outages.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Where is a UPS typically installed in data centers?

A

At the bottom of each rack

Some data centers may use larger UPS systems to support multiple racks or the entire facility.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is a Power Distribution Unit (PDU)?

A

A specialized device that distributes electric power to network components and computing equipment

PDUs are advanced power strips that may include power monitoring and control features.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are the characteristics of a PDU?

A

May be rack-mounted or in large cabinets, provides surge protection but not full protection against complete power loss

PDUs are crucial for managing power supply in environments with multiple servers.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the function of generators in data centers?

A

Provide longer-term power during outages

Generators are typically powered by diesel, gasoline, or propane and are paired with UPS for seamless power transition.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the role of an automatic transfer switch?

A

Shifts power between UPS and generator

This ensures that power supply is maintained without interruption during an outage.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Why is Power Load Management critical?

A

Prevents circuit overloads and ensures efficient power usage

It requires careful calculation and monitoring of power loads on circuits.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What must be considered when installing new equipment in a data center?

A

Assessing power impact and balancing loads across the data center

This ensures that existing circuits are not overloaded and that power distribution remains efficient.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the US standard voltage for power distribution?

A

120 volts

This standard voltage is crucial for ensuring that equipment operates properly.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the European standard voltage for power distribution?

A

230 volts

Equipment must match these voltage standards to avoid damage or operational issues.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What can dual voltage equipment do?

A

Operate on both US and European voltage standards

This flexibility is beneficial for equipment used in international settings.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What are some key considerations for data center power management?

A

Install UPS, PDU, and backup generator, ensure seamless power transition, consider power loads and voltage requirements

These considerations help maintain reliability and efficiency in data center operations.