RCS Flashcards
When RCS > what temperature, is
a continuous MU bypass flow of
how many gpm to B HPI?
> 250F, flow of 3 gpm
Be at least what delta k/k
shutdown if the most conservative
WR cold leg temp is less than
what?
1% delta k/k, <525F
Do NOT open pzr spray valve
unless delta T between RCS and
pzr is less than or equal to what
temperature?
250F
Maintain RCS dissolved gas <
what setpoint H2O to prevent
accumulation in CRDM?
<100 cc/kg H2O
Pzr H/U and C/D rate?
100 F/HR
Maintain min pzr spray bypass
flow of what gpm when RCS >
what temperature?
.75 gpm and RCS >200F
When venting pzr to RCDT at low
pressure, avoid large pressure or
level transients by using what?
Small taps on RC-V-28 OPEN
pushbutton
Tech specs
Leakage: basis is “leak before
break” strategy
When Rx critical > what percent power,
how many RCS leak detection systems
of different operating principles shall be
in operation with X of X sensitive to
radioactivity. Systems may be OOS up
to how many hours provided RB atm
samples how many hours?
> 2%
2 RC leak detection systems
1 of 2 sensitive to radioactivity
OOS up to 72 hours
RB atm sampled 8 hours
Normal Makeup flow path
RC-P-1B discharge via B HPI/MU-
V-17
Letdown flow path
RC-P-1C suction line via MU-V-
1A/B
Pressurizer Surge line
A Hot Leg
Pressurizer spray line
RC-P-1A discharge via RC-V-1/3
Drop Line
B hot leg via DH-V-1/2/3
HPI
RCP discharge lines via MU-V-
16A/B/C/D
LPI
CF Nozzles via DH-V-4A/B
Once through steam generators (RC-
H-1A/B)
EFW nozzles: how many nozzles per
OTSG, sprays where to promote what
and reduce thermal stress on what?
7 nozzles per OTSG, sprays on
tubes to promote natural circulation,
reduce thermal stresses on the
lower tube sheet
Tube to shell DT: tensile and
compressive temperatures
-70F (tensile) or +60F
(compressive)
RCDT (WDL-T-3): Auto signals does
what?
IC-V-20 opens w/ WDL-P-8 starts
(110F, trips @ 105F if IC-V-4 is
OPEN).
RCDT relief valve set point
40 psig
RCDT rupture disc setpoint
55 psig
OTSG milestones High to Low (just
percentages)
97.5% HSPS FW isolation (2/4)
90% ICS HLL (auto control)
88% HI OTSG level alarms
75-85% Loss of 25F SCM
50% Loss of 4 RCPs HSPS Auto
contro
OTSG milestones High to low (just inches
of vacuum)
25” S/U LLLs (AUTO), HSPS EFW
control (Auto)
- Loss of both FWPs, 10” OTSG,
4#RB
20” S/U OTSG low level alarm
10” S/U HSPS low OTSG lvl EFW
AUTO start
Pressurizer RC-T-2 capacity
12 gal/inch