RCS Flashcards

1
Q

When RCS > what temperature, is
a continuous MU bypass flow of
how many gpm to B HPI?

A

> 250F, flow of 3 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

Be at least what delta k/k
shutdown if the most conservative
WR cold leg temp is less than
what?

A

1% delta k/k, <525F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Do NOT open pzr spray valve
unless delta T between RCS and
pzr is less than or equal to what
temperature?

A

250F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Maintain RCS dissolved gas <
what setpoint H2O to prevent
accumulation in CRDM?

A

<100 cc/kg H2O

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Pzr H/U and C/D rate?

A

100 F/HR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Maintain min pzr spray bypass
flow of what gpm when RCS >
what temperature?

A

.75 gpm and RCS >200F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When venting pzr to RCDT at low
pressure, avoid large pressure or
level transients by using what?

A

Small taps on RC-V-28 OPEN
pushbutton

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Tech specs
Leakage: basis is “leak before
break” strategy

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When Rx critical > what percent power,
how many RCS leak detection systems
of different operating principles shall be
in operation with X of X sensitive to
radioactivity. Systems may be OOS up
to how many hours provided RB atm
samples how many hours?

A

> 2%
2 RC leak detection systems
1 of 2 sensitive to radioactivity
OOS up to 72 hours
RB atm sampled 8 hours

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Normal Makeup flow path

A

RC-P-1B discharge via B HPI/MU-
V-17

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Letdown flow path

A

RC-P-1C suction line via MU-V-
1A/B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Pressurizer Surge line

A

A Hot Leg

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Pressurizer spray line

A

RC-P-1A discharge via RC-V-1/3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Drop Line

A

B hot leg via DH-V-1/2/3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

HPI

A

RCP discharge lines via MU-V-
16A/B/C/D

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

LPI

A

CF Nozzles via DH-V-4A/B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Once through steam generators (RC-
H-1A/B)
EFW nozzles: how many nozzles per
OTSG, sprays where to promote what
and reduce thermal stress on what?

A

7 nozzles per OTSG, sprays on
tubes to promote natural circulation,
reduce thermal stresses on the
lower tube sheet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Tube to shell DT: tensile and
compressive temperatures

A

-70F (tensile) or +60F
(compressive)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

RCDT (WDL-T-3): Auto signals does
what?

A

IC-V-20 opens w/ WDL-P-8 starts
(110F, trips @ 105F if IC-V-4 is
OPEN).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

RCDT relief valve set point

A

40 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

RCDT rupture disc setpoint

A

55 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

OTSG milestones High to Low (just
percentages)

A

97.5% HSPS FW isolation (2/4)
90% ICS HLL (auto control)
88% HI OTSG level alarms
75-85% Loss of 25F SCM
50% Loss of 4 RCPs HSPS Auto
contro

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

OTSG milestones High to low (just inches
of vacuum)

A

25” S/U LLLs (AUTO), HSPS EFW
control (Auto)
- Loss of both FWPs, 10” OTSG,
4#RB
20” S/U OTSG low level alarm
10” S/U HSPS low OTSG lvl EFW
AUTO start

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Pressurizer RC-T-2 capacity

A

12 gal/inch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Pressurizer RC-T-2 Heaters, how many groups and how many heaters in each of how many banks?
13 groups, 9 heaters in 5 banks
25
Pressurizer Heater Banks, which ones and how are they controlled?
Banks 1,2,3 are SCR Controlled (variable heat demand) Banks 4 and 5 are bistable Controlled (on/off)
26
Pressurizer heater control table, setpoints
Find table
27
Where does MU come in?
MU from downstream RCP B between pump and RX
28
Where does HPI come in?
Between all RCP and RX
29
Where is let down go?
Suction side of RCP C
30
Pressurizer Power Supply:
1E and 1F 480V switchgear, 1A and 1B PZR Heater MCC’s
31
Pressurizer emergency power
Group 8 or Group 9, 1P or 1S 480V switchgear
32
Pressurizer interlocks All heaters De-energize at what pressurizer level (what level does it uncover) EXCEPT when powered from where?
80” pressurizer level (63.5” uncovered) EXCEPT when powered from 1P/1S ES switchgear
33
Can’t energize heaters < what pzr level (interlock bypass key where?) ON a loss of what you would need to defeat the interlock that actuates.
<80” (interlock bypass key in ICS/NNI cabinet) ON a loss of ICS AUTO power, interlock actuates and you need to defeat this
34
Which pzr groups trips on Es?
Groups 8 and 9
35
Which group has 69 bypass on 1s 480v to prevent tripped on ES when in emergency?
Group 9
36
Pzr level control Nominal level ensures pzr does not what post trip to prevent what?
Ensures pzr does NOT empty post trip to prevent loss of SCM
37
Pzr tech specs Pzr HU and CD rates shall NOT exceed what F/hr?
100F/HR
38
RX shall be maintained subcritical >what percent deltaK/k until pzr level what to what inches or else be in HSD w/ CRD breakers Open in how many hours and CSD in how many hours?
>1% deltak/k until pzr level 80-385” or else Be in HSD w/ CRD breakers OPEN in 6 hours and CSD in 30 hours
39
Pressurizer spray power supply
1A ES MCC
40
Pressurizer spray Auto signals:
Close at 2155#, OPEN at 2205# RCS to 40%@ 140 gpm
41
Manual Control: RC-v-1 can be OPENED in JOG up to 100% (190 gpm). Must place switch back to what position, will only close at what pressure in auto?
Auto 2155# in Auto
42
Where is HPI come in at?
RCP discharge side on all legs
43
RCITS
HOT leg level: RCPs off Reactor vessel level: RCPs off % void fraction: RCP’s operating RCS Drain Down Level: RCS drained down
44
MU-V-17 normal makeup
220” by the MU system using normal MU valve, MU-V-17 in automatic and letdown flow
45
Dry OTSG
<200 psig below saturation pressure And less than 6”
46
If you have a void in the hotleg can you have natural circulation?
No you can’t establish natural circ with a void in the hot leg
47
Can’t start a 4th RCP unless you’re above what temperature
407 F
48
Why do we need to compensate pzr level temperature?
It’s a differential pressure detector
49
How many pressure detectors in A hot leg? What pressure bands and used for what?
5, two narrow ranges/rosemound detectors: 1700-2500 psig For RPS, PORV, heaters and spray 2 wide ranges/bourdon tubes 0-2500 psig For ESAS, PORV, DH interlocks One wide range rosemount detector Safety grade (post accident) 0-3000 psig Used for Tsat memters, DSS trip
50
What type of flow tube in each hot leg? Connected to how many differential pressure instruments?
Gentile flow tube Connected to 4 differential pressure instruments
51
Pressurizer spray Purpose, if spray fails OPEN, plant may remain online by doing what?
Condenses steam to reduce pressure, RC-P-1A discharge normal source. Kept online by closes RC-V-3 (block valve) which is the pressurizer spray isolation valve
52
Power supply to spray isolation valve (RC-V-3)
1B ES MCC
53
Pressurizer spray isolation valve (Rc-v-3) Purpose
Isolations (full open/close) if rc-v-1 fails but eliminates bypass flow
54
Pressurizer spray isolation bypass (rc-v-24) Purpose
Maintains .75-1.5 gpm flow around spray valve RC-V-1 to prevent thermal shock to the spray valve and nozzle and continuous outflow from pzr to equalize boron concentration “mixing” (within 50 ppm)
55
Pressurizer Aux Spray (RC-V-4) Type of valve, power supply, purpose
MOV 1C ES valves MCC Provides pzr spray at low pressures during cooldown from discharge of decay heat pumps
56
High Pressure relief PORV (RC-RV-2) Type of valve? Power supply?
MOV/SOV 1C 250V DC
57
PORV Auto signals
OPEN at RCS #2450, CLOSE at RCS #2400
58
PORV Tech specs LTOP porv pressure when RCS is less than what temperature? How long to restore or verify pzr level is less than or equal to what?
<313F is 592# Restore in 8 hours or verify pzr level ≤100”
59
If LTOP not in effect, PORV min setpoint is what pressure? Restore in how much time OR shut what OR shut and remove power from PORV OR be in what in how much time and CSD in how much time?
PORV min setpoint is #2425 Restore in 8 hours OR Close block valve OR Close and remove power form PORV OR Be in hotstandby in 6 hours and CSD in 30 hours
60
When RCS is less than what temp, PORV shall NOT be taken OOS or isolated unless HPI pumps racked OUT, MUV-what Closed w/ bkrs to what position and MU-V-what Closed/open or RX head off.
<313F MUV-16’s Breakers open (MUV-16) MUV 217 closed
61
PORV clock valve shall be OPERABLE during hsby, s/u and power ops. If INOPERABLE, restore in how much time or close what and remove power OR be in hsby in how much time and CSD in how much time?
Restore in 1 hour OR Close PORV (verify closed) And Remove power OR Be in hsby in 6 hours or CSD in 30 hours.
62
PORV tech spec Design basis
Prevents overpressure by eliminating high pressure sources or assuring RCS open to atm. Block valve required to provide isolation of PORV to control potential RCS depressurization
63
PORV NDTT Switch Two position switch located on PC which changes PORV setpoint for LTOP concerns when RCS is less than what temp? in off setpoint is what? In auto position the OPEN setpoint to what pressure and Close at what pressure when Tcold is < what?
RCS <313F In OFF setpoint is #2450 In Auto open is #592 and close at #542 when Tcold <313F
64
PORV Other NDTT switch kept OFF because a single failure of WR Tcold instrument LOW would cause the PORV to OPEN. Per 1101-11, we place NDTT switch to what position after RCS< what temp and prior to RCS < what temp?
Place NDTT switch in Auto after RCS<565F and prior to RCS <313F
65
PORV isolation valve (RC-V-2) Type of valve and Power supply
MOV, a D-ring top of pzr 1C ES valves MCC
66
Most important pzr level mile stone
370” Enter AOP-43 loss of pressurizer and trip RX
67
Porv acoustic monitors (2 channels) Located on valve body, indicates if PORV is OPEN, alarm annunciator at how many G’s (%)
0.3G’s (5%)
68
Tail pipe (delta P)(3 channels) 1 for PORV, 2 for code safeties Indication on CC, how many inches delat p alarm setpoint (%)
20” delta P alarm setpoint (5%)
69
Tail Pipe delta P (3 channels) T.S. 3.5.5 accident monitoring requires how many channels, how many minimum?
2 channels with 1 minimum