Reactor Makeup Water Flashcards

(11 cards)

1
Q

List the power supplies for BAT Pump u-01 & u-02

A

uEB1-1: u-01
uEB4-1: u-02

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the six operating modes of the reactor makeup system?

A
  1. Off
  2. Auto
  3. Manual
  4. Dilute
  5. Borate
  6. Alt Dilute
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What conditions will give a ‘BA FLO DEV’ alarm and what are the automatic actions?

A

Desired flow is not obtained within +/- 1 gpm within 25 seconds.

Automatic actions:
- Closes FCV-110B and FCV-111B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What conditions will give a ‘RMUW FLOW DEV’ alarm and what are the automatic actions?

A

Desired flow is not obtained within +/- 8 gpm within 25 seconds.

Automatic actions:
- Closes FCV-110B and FCV-111B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How many gpm per rotation of the BA flow controller pot-dial?

A

4 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How many gpm per rotation of the RMUW flow controller pot-dial?

A

16 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The preferred emergency boration flowpath flows through this MOV valve, what is it and where is it powered from?

A

Preferred emergency boration flowpath is through u-8104 and it’s powered from uEB4-1.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is total flow limitation of the reactor makeup system operating in AUTO?

A

127 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the administrative maximum boric acid flow at a concentration >1600 ppm?

A

27 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

FCV-110A/B & FCV-111A/B are DC solenoid-operated valves that share a power supply, where does this power come from? Additionally, each of these valves fail close on a loss of power or air with the exception of one. Which valve is this exception and why?

A

FCV-110A/B & FCV-111A/B are powered from uED1-1

FCV-110A is the exception, it fails open. This is to ensure a boric acid flowpath is available following a loss of power.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

In the event of an emergency, there exist four emergency boration flowpaths. What are these flowpaths called and what are their credited flow rates?

A

Emergency Boration:
- Through u-8104: 75 gpm
Manual Emergency Boration
- Through uCS-8439: 36 gpm
Alternate Emergency Boration:
- Through FCV-110B & FCV-111B: 27 gpm
Gravity Feed Emergency Boration:
- Through u-8507 & u-8509: No restriction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly