SCBA Flashcards
SCBA regulator diaphragm is made of ——- ——- similar to a
level ‘A’ entry suit 1.2
Butyl rubber
The CBRN approval means that the SCBA has met the Niosh and NFPA criteria for exposure to which 2 agents?
1.2
Liquid mustard and Sarin agents
And approved SCBA CBRN regulator can be identified by its ——-background label?
1.2
Orange background label
An approved back frame assembly for your SCBA can be identified by a?
1.2.
CDC NIOSH sticker
T/F because the facepiece does not cover the ears, airborne contaminants can enter the respiratory tract through a punctured or ruptured eardrum. 2.1.3.
True
If a member runs out of air, what is the first thing they should do? 2.1.7.
Remove regulator then notify Officer
Which is wrong?
Definition of confined space are:
Not designed for continuous human occupancy ,
Small enough so a person can enter and work ,
Has limited means for entry and escape 2.2
Large enough so a person can enter and work
Is a windowless building considered a confined space? 2.2.1
Yes
T/F
In terms of confined space members must operate in teams of two. 2.2.4
False
2 or more and maintain contact
Which bullet point is wrong?
1- the SCBA is never to be used underwater.
2- submersion in water will render the SCBA inoperative.
3-if the SCBA becomes submerged, it shall be placed out of service and returned with a completed service tag RT-2 stating the problem to MSU. 2.4
3
It must be placed out of service.
The service life for the air cylinder is
—— years. 3.2.3
Hydrostatic testing is done every ——- years. 3.2.4
15 years
5 years hydrostatic
SOC Escape Cylinders are hydrostatic every 3 years.
The hydrostatic test date for cylinders will be found where on the cylinder? 3.2.4
Top
For example, the number 102 will indicate that the cylinder was tested in January 2002 next retest will be January 2007.
Month then Year
SCBA, the end of service time indicator alarms, Vibralert and HUD actuate when approximately —% of full cylinder pressure remains in the cylinder and valve assembly. 3.2.8
25%
SCBA, inspect all spare cylinders at depot’s high-rise units company and reserve apparatus ——on ——-for full pressure at ——. 3.2.12
Weekly on Monday
4500 psi
T/F SCBA, avoid fully depleting cylinders and leaving valve open. Doing so will allow moisture and contaminants to build up inside the cylinder.3.2.14
True
SCBA designated training cylinders identified with ——- . 3.2.15
Blue top and/or polymer protective sleeve
Do not use for firefighting purposes
SCBA to replace or tighten the nylon O-ring there are two tools you need what are they and their sizes?
3.4.2
1/8 Allen Wrench
7/16 open end wrench
T/F SCBA, a missing UAC dust cover shall be placed out of service 3.5.2
True
SCBA. PRA, is usually mounted on the ——- side of the back frame reduces the high pressure breathing air received from the cylinder. Consistent of two systems the PRA normally reduces its operating pressure to ——-psi before entering the regulator low pressure hose. The regulator then controls the pressure within the facepiece to slightly ————-. 3.6.1.
Left side
100psi
Slightly above atmospheric pressure.
A malfunction of the PRA primary system will automatically direct breathing air into a secondary system. When this occurs the operating pressure will be reduced to ——- psi and cause ——— to activate. 3.6.2.
150 psi
Vibralert alarm
Failure of both the primary and secondary systems in the ——position will activate a ——- ———in the PRA, which will rapidly dischargeable pressure in excess of —- psi into the atmosphere. When the occurs the cylinder valve should be ——- ——-, allowing only a minimal amount of air to release permitting the member to both breathe and conserve. 3.6.3.
Open position
Relief valve in the PRA
Excess of 185 psi
Partially closed
SCBA. If the manual shut off fails to release for any reason, turn the ——- valve in which direction?
How many degrees to start the flow of air?
3.8.2. B
Purge valve
Downward
180°
SCBA. When the regulator is correctly positioned on the facepiece, a stem on the purge valve will point ——— and its normal mode. 3.8.4 A
Upwards is normal mode
SCBA. Purge valve. For the following emergencies.
1- failure of the regulator in the closed position, turn, purge valve ——- - ———-.
2- If failure of the regulator in the open position, air flow can be controlled by opening the ——valve, ——— and partially closing the cylinder valve. 3.8.4.B
1- Counter -Clockwise
2- purge valve fully
Partially closing cylinder valve