Tool27 Evolution 6000 TIC Flashcards
(27 cards)
How do you verify TIC is functioning? 2.1.
Viewing your hand or another member
TIC
High heat will go into —— sensitivity mode indicator 3.1
Low sensitivity
TIC
What is the indication of high heat low sensitivity mode and where is it on located on the display ?
3.1
Green triangle inside green square
Upper left corner.
TIC
Will shutter when shifting into which mode? 3.1.
High heat (low sensitivity) mode
TIC
High heat mode indicator. The dynamic range is ——— in the high heat (low sensitivity) mode to increase detail. 3.1.
Expanded
TIC
Internal electronics overheat indicator is indicated by?
3.2
Red thermometer in a red triangle that appears in the upper center of display
ACRO If u overheat u need R&R
TIC
Internal electronics overheat indicator off (not lit) means?
3.2
Normal
TIC
Flashing red means?
3.2.
Overheat
for internal electronics overheat indicator
TIC
Temperature measurement zone is indicated by?
3.3
Green Square in center of display
TIC
Heat color reference bar and scale. What are the colors and what do they mean?
3.4
Yellow at the low end of heat color reference bar
Orange in the middle of the heat color reference bar
Red at the high end of the heat color reference bar
ACRO ROY
TIC
Low heat high sensativity-normal mode.
Yellow, how many degrees?
Orange, how many degrees?
Red, how many degrees?
3.4
Yellow 291F to 303F
Orange 302F to 311F
Red 311F to 320F
TIC
If colors yellow through red 291F-320F appear in less than ——— of the viewed area of the tic may remain in low heat, high sensitivity – normal mode, providing greater detail with colors 3.4
Less than 32%
PS more than 32% high heat, low sensitivity mode
TIC
If colors yellow through red 291F-320F appear in more than ——- of display the tic will shift into high heat, low sensitivity mode.
3.4
More than 32%
PS less than 32% remain in low heat, high sensitivity, normal mode, providing greater detail with colors.
TIC.
When will the TIC shutter?
3.4 
When colors yellow through red 291 to 320 appear in more than 30% it will shift into high heat low sensitivity mode.
TIC
Where and what symbol will the high heat low sensitively mode indicator appear on the TIC?
3.4
Upper left-hand corner of display
Green Triangle inside Green Square
TIC.
One yellow through red appear in more than 32% of the display it will shift into high heat, low sensitivity mode, heat, color reference, bar, and scale expands and a —— ——- appears over the scale indicate the change. 3.4.
Green triangle
TIC
High heat, low sensitivity mode ,
What are their colors and ranges?
3.4
Yellow 1000-1047
Orange 1047-1090
Red 1090-1100
TIC
Greater than 320°F to 351°F in the low heat high sensitivity – normal mode because of the TIC limited dynamic range in —— ——-.
Note
Low heat, high sensitivity, normal mode
TIC
Uses must be aware and understand that the temperature measurement feature in a thermal image will not provide ——- or ——-.
3.4
Atmospheric or air temperature readings.
ACRO AAT Atmospheric/AirTemp
TIC
The numeric temperature indicator (shall or shall not ?) be utilized or relied upon to make tactical interior structural firefighting decisions. Note page 4.
Shall not
TIC
Battery/power status indicator, each LED segment represents approximately —— minutes of operational time. 3.6.
40-45 minutes
TIC
Battery/ Power status indicator.
If the —— —— flashes —- times at turn on, the battery is too low to operate and the TIC will shut off.
3.6.
Red LED
Three times
TIC
Shutter indicator, is indicated by what 3.7
Green square just below the upper left corner of the display for approximately 3 seconds before and during the shuttering cycle.
ACRO SS Square Shutter
TIC
Shutter indicator, when the camera shutters, the camera image freezes for approximately? 3.7.
Approximately one second
PS shuttering may occur more frequently with greater heat load.