What are common causes/conditions of condensation?
Condensation is a common occurrence in homes and is caused by warm, moist air coming into contact with cold surfaces. This can happen for a number of reasons, including:
- Everyday activities: Many activities in the home, such as cooking, showering, washing clothes, and breathing, produce moisture.
- Inadequate ventilation: When there isn’t enough ventilation, moisture can build up.
- Poor insulation: Low levels, missing or incomplete insulation can create cold spots in the home.
- Single glazing: Single glazed windows can’t warm up, which can lead to condensation.
What are the effects of condensation, and how can you spot it?
Condensation can often be spotted most easily on windows, where water droplets form on the window pane. It is also common to see water droplets forming in other areas with cold surfaces and where ventilation is poor, such as the corners of the room or behind furniture. Long term condensation can also begin to caused damage to the finishes and building elements. It is also common for condensation to have a musty smell.
If the water droplets are not removed, this can develop into black mould, which can be harmful to health.
Advise on the differences between condensation and damp.
Condensation is a type of moisture that forms on cold surfaces when warm, humid air cools down, while dampness is a result of penetrating water through walls, floors, and ceilings.
Are you aware of any guidance from the RICS on damp and mould.
RICS produced a Joint Position Statement (JPS) on investigating moisture and its effects on traditional buildings. The JPS was created in collaboration with Historic England and the PCA.
Explain your understanding of the Joint Position Statement, September 2022.
The JPS is a framework to guide surveyors through the best practice for investigating moisture related defects in traditional buildings. It establishes surveyors needs for knowledge and competence in the following areas:
Understanding the building to create a holistic picture.
Understanding moisture.
Understand moisture related building defects.
How to carry out a condition assessment.
Diagnosis and recommendations.
Legal requirements such as BC, planning and other standards.
Report accurately to the client.
What are the limitations of a damp meter?
Electrical resistance meters are not accurate for measuring moisture in masonry. While they can be used to establish profiles, they are not quantitative, due to salts, free water and metal content.
What is thermal imaging and what can it tell you?
Surveyors use thermal imaging, also known as thermography, to identify defects and energy deficiencies in buildings. Thermal imaging generates images of objects by capturing the infrared radiation they emit and shows differences in energy absorption and loss. Thermal imaging is a non-invasive technique that can be used to detect; dampness, cold bridges, leaking underfloor heating pipework and heat loss.
What are the limitations of a thermal imaging camera?
Obtaining useful information depends to a large extent on the basic principles of heat transfer, so the conditions at the time of the survey need to be correct.
* constant internal temperature of 20–22C for at least 72 hours before inspection
* a minimum temperature differential of 10C, between internal and external.
* clear internal faces to external walls; note that if there is a void behind a surface you will not record any useful infrared emissions from that source
* internal doors left open to encourage even heating
* no windows or external doors left open, as this would encourage cold air ingress.
How do thermal imaging cameras help to identify damp defects?
In the context of damp detection, thermal imaging can be used to identify areas of moisture in a building. This is because as moisture is lost from a surface by evaporation, it cools that surface and, as a result, areas of damp will often appear cooler in a thermal image than the surrounding areas.
However, a cold surface does not always indicate dampness. Once thermal images find an area of interest, this area should be inspected using more traditional methods.
If you are planning to use a thermal imaging camera, how would you inform the client to adequately prepare?
I would inform them that the accuracy of the thermal imaging survey will, to a large extent depend on the conditions as the time of the survey, so they will need to prepare appropriately to ensure the following:
* There is a constant internal temperature of 20–22C for at least 72 hours before inspection.
* There is a minimum temperature differential of 10C, between internal and external areas.
* The internal faces to external walls are clear.
* The internal doors are left open to encourage even heating.
* No windows or external doors left open, as this would encourage cold air ingress.
What are the common causes for structural movement?
Subsidence. Settlement. Frost Heave. Ground Heave. Removal of trees. Sulphate attack. Lintel failure.
How can you identify structural movement?
Cracks in walls, ceilings, or foundations can indicate structural movement.
Cracks that are large and vertical, or diagonal and wider at the top, are especially significant. Cracks above doorways that form a step pattern, or that appear with uneven floors or sagging ceilings, are also a cause for concern.
Doors and windows sticking or not opening or closing properly.
Walls that bow, bulge, or lean outward.
Floors that appear uneven or slant.
Gaps between walls and ceilings or floors.
How do electric resistance meters (damp meters) work?
Pin or probe types work by measuring the electrical resistance between two probes or pins to determine the moisture content of a material.
Pinless meters are non-invasive meters detect moisture using conductance by either radio frequency or capacitance of a material. Its readings are helpful for quickly determining moisture presence in a space. They should be further investigated and confirmed by taking measurements with a pin-type meter.
What are the housing periods in the UK?
Georgian and Regency – 1714 – 1837.
Victorian and Edwardian – 1837 – 1901 / 1901 – 1914.
Post WW1 Housing – 1918 – 1939
Post WW2 Housing – 1945 – 1990’s
What are some common defects of Georgian, Regency, Victorian and Edwardian Houses?
Arch failure – with timber backed lintels.
Bonding failure between walls.
Condensation.
Drainages problems.
Inappropriate use of cement mortar.
Inadequate foundations.
Lack of DPC.
Over stressed joists.
Penetrating damp, causing wet or dry rot to timbers and joists.
Poorly ventilated ground floors.
Failure of roof coverings.
What are some common defects in Post-War housing (1918 – 1939 /1945 – 1990)?
Failure of wall ties
Sulphate attack in floors
Cracking caused by unconsolidated hardcore.
Rising damp in early concrete floors with missing DPM.
Undersized floor joists due to lack of materials.
Fungal attack on external wood due to poor quality of wood.
What are some common defects with sand and cement render and why?
Cracking and shrinking are probably the most common defects that I have come across. Cement render is more prone to cracking and shrinking because they are less flexible and are less likely to be able to withstand thermal or moisture changes, or movement of the substrate.
What are common defects with flat roofs and why?
Blistering.
Cracking/splitting.
Ponding water.
Defects at upstands, where two structures meet.
What are some common defects with pointing and why?
Occasionally, pointing mixes are installed that mortar that is too dense (i.e too much cement). This will not allow the brickwork to ‘breath’ adequately and it will shrink and crack, which allows water ingress.
What are some common defects with timber windows and why?
Rotting – windows can rot over time due to harsh weather conditions.
Warping – changes in temperature and humidity can lead to warping.
Snapped sash cords.
Peeling paint.
At Ditton Hill Road, what was the pattern of cracking that indicated there was an issue with the support mechanism over the double doors?
As the lintel was absent, there was no structure supporting the brickwork or load above, leading to settlement of the brickwork over the opening. This caused diagonal cracking in the masonry over the opening, which were wider at the top than the bottom.
Why did the lack of a lintel at Ditton Hill Road, lead to settlement cracking?
As there was no support to the structure above, so it settled, and cracks because visible in the mortar joints.
What alterations were required at Ditton Hill Road to rectify the lintel issue?
I advised the client that this was unsafe, and a new lintel would need to be installed immediately. This would require removing brickwork and installing props to support the masonry above the opening, so that a suitable lintel could be installed.
I advised that a structural engineer would be required to specify the lintel required.
How did you identify that there was wet rot within the loft space in Ditton Hill Road?
When I entered the loft area, I was initially hit with a damp musky smell. I noted that the timbers in and around the valley board were a far darker shade and the timber had a moisture content of around 50% when test with a pronged damp meter, suggesting that the timbers were suffering from continued wetting. All of which are characteristics of wet rot.