CSP Domain 5: Emergency Preparedness, Fire Prevention, And Security Flashcards Preview

Certified Safety Professional Exam > CSP Domain 5: Emergency Preparedness, Fire Prevention, And Security > Flashcards

Flashcards in CSP Domain 5: Emergency Preparedness, Fire Prevention, And Security Deck (46)
Loading flashcards...
1

DOT Hazard Class 3

Flammable Liquids

2

DOT Hazard Class 5

Oxidizers
5.1 oxidizer
5.2 organic peroxide

3

DOT Hazard Class 6

Poisons

6.1 Poison Inhalation

4

DOT Hazard Class 8

Corrosive Materials

5

Which sprinkler systems are heat sensors removed from the sprinkler heads by design

Deluge system

6

What type of heat transfer does not require a physical medium?

Radiation- heat transfer due to the emission of electromagnetic waves

7

A hybrid of a wet, a dry, and a deluge sprinkler system is known as a:

Precaution System

8

Why would it be a bad idea to install a heat detector in a bathroom near a shower?

The alarm may be falsely triggered.

9

What do the number ratings on class B or C extinguishers indicate?

How many square feet of coverage the unit will contain

10

According to OSHA, what are some examples of times when a fire extinguisher is NOT required to undergo Hydrostatic testing

-when unit has been repaired by soldering, welding, etc.
-when cylinder or shell threads are damaged
-when there is corrosion that caused pitting
-when the extinguisher has been burned in a fire
-when calcium chloride extinguished agent has been used in a stainless steel shell

11

What are the parts of the Preparedness step in planning for emergencies?

Planning
Establishing command system and communications
Training
Exercises
Education

12

Heat transfer from the movement of a bulk fluid such as air or water

Convection

13

Under RCRA, what materials designation is associated with materials that exhibit a hazardous waste characteristic?

Code “D”

14

DOT Hazard Class 9

Miscellaneous Hazardous Materials including:
Magnetized materials
Elevated Temperature Goods
Dry Ice
Asbestos
Environmentally Hazardous Substances
Life Saving Appliances
Internal Combustion Engines
Zinc Dithionite
Saccharin

15

Phenomenon of particulates or gases adhering to the surface of filter media

Adsorption

16

Flow rate of a fire hydrant with a ORANGE top?

500-1000 GPM

17

Under RCRA, what materials designation is associated with commercial chemical sources

Code “P” or “U”

18

DOT Hazard Class 7

Radioactive materials

19

Explain NFPA Quandrant Diamond Symbols

Blue: Health hazard rating
Red: Flammability hazard rating
Yellow: Instability hazard rating
Then the hazards are ranked from 0-4 for increasing degree of hazard

20

BLUE sprinkler head is activated at what ceiling temperature?

225 deg F

21

RED sprinkler head is activated at what ceiling temperature?

300 deg F

22

WHITE sprinkler head is activated at what ceiling temperature?

150 deg F

23

Minimum temperature at which a liquid gives off vapor within a test vessel in sufficient concentration to form an ignitable mixture with air near the surface of the liquid

Flash point

24

DOT Hazard Class 2

Gases

2.1 Flammable Gas
2.2 Non Flammable Gas
2.3 Poison Gas

25

Flow rate of a fire hydrant with a GREEN top?

1000-1500 GPM

26

The lowest temperature of a liquid in an open container at which vapors evolve fast enough to support continuous combustion

Fire point

27

Describe the fire tetrahedron

Top part of diamond represent fuel
Right side represents heat
Left side represents oxygen
Bottom represents chemical chain reaction

28

GREEN sprinkler head is activated at what ceiling temperature?

375 deg F

29

Flow rate of a fire hydrant with a RED top?

500 GPM

30

Heat transfer by direct contact between two objects

Conduction