Exe Fault Code - Full Check List Flashcards

Exe Fault Codes - Includes Grade of Inspection (43 cards)

1
Q

FAULT CODE A.1

A

Equipment is appropriate to the EPL/Zone requirements of the location. : DETAILED, CLOSE, VISUAL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

FAULT CODE A.2

A

Equipment Group is correct. : DETAILED, CLOSE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

FAULT CODE A.3

A

Equipment temperature class is correct (gas only). : DETAILED, CLOSE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

FAULT CODE A.4

A

Equipment maximum surface temperature is correct (dust only). : DETAILED, CLOSE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

FAULT CODE A.5

A

Degree of protection (IP) of equipment is appropriate for the level of protection/group/conductivity. : DETAILED, CLOSE, VISUAL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

FAULT CODE A.6

A

Equipment circuit identification is correct. : DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

FAULT CODE A.7

A

Equipment circuit identification is available. : DETAILED, CLOSE, VISUAL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

FAULT CODE A.8

A

Enclosure, glass parts and glass-to-metal sealing gaskets and / or compounds are satisfactory. : DETAILED, CLOSE, VISUAL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

FAULT CODE A.9

A

There is no damage or unauthorized modifications. : DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

FAULT CODE A.10

A

There is no evidence of unauthorized modifications. : DETAILED, CLOSE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

FAULT CODE A.11

A

Bolts, cable entry devices (direct & indirect) and blanking elements are of the correct type, are complete and tight.
Cable Glands are of correct type and correctly installed for the location, and type of enclosure. : DETAILED, CLOSE, VISUAL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

FAULT CODE A.14

A

Condition of enclosure gaskets is satisfactory. : DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

FAULT CODE A.15

A

There is no evidence or ingress of water or dust in the enclosure in accordance with the IP rating. : DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

FAULT CODE A.17

A

Electrical Connections are tight. : DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

FAULT CODE A.18

A

Unused terminals are tightened (gas only). : DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

FAULT CODE A.19

A

Enclosed-break and hermetically sealed devices are undamaged (‘n’ only). : DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

FAULT CODE A.20

A

Encapsulated components are undamaged (gas only). : DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

FAULT CODE A.21

A

Flameproof components are undamaged (gas only). : DETAILED

19
Q

FAULT CODE A.22

A

Restricted breathing enclosure is satisfactory (type ‘nR’ only). : DETAILED

20
Q

FAULT CODE A.23

A

Test port, if fitted, is functional (type ‘nR’ only). : DETAILED

21
Q

FAULT CODE A.24

A

Breathing operation is satisfactory (type ‘nR’ only). : DETAILED

22
Q

FAULT CODE A.25

A

Breathing and draining devices are satisfactory (gas only). : DETAILED, CLOSE

23
Q

FAULT CODE A.26

A

Fluorescent lamps are not indicating end-of-life effects. : DETAILED, CLOSE, VISUAL

24
Q

FAULT CODE A.27

A

HID lamps are not indicating end-of-life effects. : DETAILED, CLOSE, VISUAL

25
FAULT CODE A.28
Lamp type, rating, pin configuration and position are correct. : DETAILED
26
FAULT CODE A.29
Motor fans have sufficient clearance to enclosure and / or covers, cooling systems are undamaged, motor foundations have no indentations or cracks. : DETAILED, CLOSE, VISUAL
27
FAULT CODE A.30
The ventilation airflow is not impeded. : DETAILED, CLOSE, VISUAL
28
FAULT CODE A.31
Insulation resistance (IR) of the motor windings is satisfactory. : DETAILED
29
FAULT CODE B.1
Type of cable is appropriate. : DETAILED
30
FAULT CODE B.2
There is no obvious damage to cables. : DETAILED, CLOSE, VISUAL
31
FAULT CODE B.3
Sealing of trunking, ducts, pipes, conduits is satisfactory. : DETAILED, CLOSE, VISUAL
32
FAULT CODE B.5
Integrity of conduit system and interface with mixed system is maintained. : DETAILED
33
FAULT CODE B.6
Earthing connections, including any supplementary earthing bonding connections are satisfactory (for example connections are tight and conductors are of sufficient cross-section). : DETAILED, CLOSE, VISUAL
34
FAULT CODE B.7
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory. :DETAILED
35
FAULT CODE B.8
Automatic electrical protective devices are set correctly (auto-reset not possible). :DETAILED
36
FAULT CODE B.9
Automatic electrical protective devices operate within permitted limits. :DETAILED
37
FAULT CODE B.10
Specific conditions of use (if applicable) are complied with. :DETAILED
38
FAULT CODE B.11
Cables not in use are correctly terminated. :DETAILED
39
FAULT CODE B.13
Variable voltage / frequency installation in accordance with documentation. :DETAILED, CLOSE
40
FAULT CODE B.23
Motor protection devices operate within the permited tE or tA time limits (type 'e' only). : DETAILED
41
FAULT CODE C.1
Equipment is adequately protected against corrosion, weather, vibration and other adverse factors. : DETAILED, CLOSE, VISUAL
42
FAULT CODE C.2
No undue accumulation of dust and dirt. : DETAILED, CLOSE, VISUAL
43
FAULT CODE C.3
Electrical insulation is clean and dry. : DETAILED