Exp Fault Code - Full Check List Flashcards
Exp Fault Codes - Includes Grade of Inspection (26 cards)
FAULT CODE A.1
Equipment is appropriate to the EPL/Zone requirements of the location. : DETAILED, CLOSE, VISUAL
FAULT CODE A.2
Equipment Group is correct. : DETAILED, CLOSE
FAULT CODE A.3
Equipment temperature class or surface temperature is correct. : DETAILED, CLOSE
FAULT CODE A.4
Equipment circuit identification is correct. : DETAILED
FAULT CODE A.5
Equipment circuit identification is available. : DETAILED, CLOSE, VISUAL
FAULT CODE A.6
Enclosure, glasses and glass-to-metal sealing gaskets and / or compounds are satisfactory. : DETAILED, CLOSE, VISUAL
FAULT CODE A.7
There are no unauthorized modifications. : DETAILED
FAULT CODE A.8
There is no evidence of unauthorized modifications. : CLOSE, VISUAL
FAULT CODE A.9
Lamp rating, type and position are correct. : DETAILED
FAULT CODE B.1
Type of cable is appropriate. : DETAILED
FAULT CODE B.2
There is no obvious damage to cables. : DETAILED, CLOSE, VISUAL
FAULT CODE B.3
Earthing connections, including any supplementary earthing bonding connections are satisfactory
(for example connections are tight and conductors are of sufficient cross-section). : DETAILED, CLOSE, VISUAL
FAULT CODE B.4
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory. : DETAILED
FAULT CODE B.5
Automatic electrical protective devices operate within permitted limits. : DETAILED
FAULT CODE B.6
Automatic electrical protective devices are set correctly. : DETAILED
FAULT CODE B.7
Protective gas inlet temperature is below maximum specified. : DETAILED
FAULT CODE B.8
Ducts, pipes and enclosures are in good condition. : DETAILED, CLOSE, VISUAL
FAULT CODE B.9
Protective gas is substantialy free from contaminants. : DETAILED, CLOSE, VISUAL
FAULT CODE B.9
No evidence or presence of condensation, vapours, mists, or oil-residue, in the enclosure. : DETAILED
FAULT CODE B.10
Protective gas pressure and /or flow is adequate. : DETAILED, CLOSE, VISUAL
FAULT CODE B.11
Pressure and/or flow indicators, alarms and interlocks function correctly. : DETAILED
FAULT CODE B.12
Condition of spark and partical barriers of ducts for exhausting the gas in hazardous area are satisfactory. : DETAILED
FAULT CODE B.12
Outet-exhaust port clear and unobstructed. : DETAILED, CLOSE, VISUAL
FAULT CODE B.13
Specific conditions of use (if applicable) are complied with. : DETAILED