fire tech 6/2 Flashcards
(29 cards)
Question text
- Which of the following tool(s) are effective when handling LEXAN at fire operations?
Select one or more:
a. Oxyacetylene torch
b. Sawzall with the coarse tooth wood blade
c. Superior Air Hammer
d. Pike Axe
e. Portable Power Saw with a carbide tipped blade
Fires 4—Pg 1) Sawzall, with the coarse tooth wood blade, is also effective on LEXAN but it is slower than the Portable Power Saw
The correct answers are: Portable Power Saw with a carbide tipped blade, Sawzall with the coarse tooth wood blade
Question text
- In NYCHA buildings, if the chute door on the first floor is color coded _____, it indicates that the building has a compactor?
Select one:
a. Black
b. Gray
c. Red
d. Silver
The correct answer is: Gray
Question text
- If you open a chute door on a floor and smoke comes out at an incinerator emergency, the blockage is generally?
Select one:
a. Below that floor
b. Above that floor
The correct answer is: Above that floor
Question text
- Which point about the fire protection in compactor rooms is incorrect?
Select one:
a. Sprinkler heads are required in the compactor unit
b. A water outlet and a hose are required in the compactor room
c. Sprinkler heads in compactor units must be arranged so that they may be readily replaced even when they are electrically operated
d. An automatic sprinkler is required in the compactor room
Feedback
(Fires 7 Sec 7) (unless they are electrically operated and approved)
The correct answer is: Sprinkler heads in compactor units must be arranged so that they may be readily replaced even when they are electrically operated
Question text
- In refuse chutes constructed in new buildings, sprinklers shall be provided?
Select one:
a. On every story for the height of the chute
b. Spaced not more than three stories apart for the height of the chute.
c. Spaced not more than two stories apart for the height of the chute
d. On every story for the height of the chute unless electrically operated
The correct answer is: Spaced not more than two stories apart for the height of the chute
Question text
- E43 and Ladder 59 arrive first at a compactor fire on the 15th floor of a 40-story High Rise Multiple Dwelling. Fire is burning at the compactor chute door on the 15th floor. In this situation, it would be correct to think Engine 43 should stretch?
Select one:
a. A 2 ½” line from the standpipe outlet to the 15th floor chute door to extinguish the fire
b. A 1 ¾” line from the standpipe outlet to the 16th floor chute door to extinguish the fire
c. A 1 ¾” line from the standpipe outlet to the 15th floor chute door to extinguish the fire
d. A 2 ½” from the standpipe outlet to the 16th floor chute door to extinguish the fire
The correct answer is: A 2 ½” from the standpipe outlet to the 16th floor chute door to extinguish the fire
Question text
- You are a company officer on duty in Engine 200 where an EEO Compliance Inspection is taking place. In regards to this inspection, you would be incorrect to believe that?
Select one:
a. If a unit in a single house or both units in a double house receive an alarm during the EEO visit, the EEO staff will terminate the inspection and leave the premises
b. The unit(s) in the firehouse will remain in service during the inspection
c. When the inspection is complete, the EEO investigator will provide the officer with a signed copy of the EEO inspection checklist
d. After EEO announces their visit to the Housewatch FF, that FF should not make any notifications unless directed to do so by EEO personnel
Feedback
(Regs 20.3.10) (Housewatch FF notifies OOD that their presence is required at the housewatch area)
The correct answer is: After EEO announces their visit to the Housewatch FF, that FF should not make any notifications unless directed to do so by EEO personnel
Question text
- If a commanding officer believes the unit’s hydrant inspection goals will not be met by the end of the inspection period, the officer should submit a letterhead report through the chain of command to the ________________ requesting assistance?
Select one:
a. Division Commander
b. Battalion Commander
c. Brooklyn Boro Command Water Supply Officer
d. Borough Commander
Feedback
(Regs 28.1.4)
The correct answer is: Borough Commander
Question text
- If an officer wishes to request the installation of a new hydrant, the request must be submitted in writing through the chain of command to the ________________?
Select one:
a. Division Commander
b. Chief of Operations
c. Brooklyn Boro Command Water Supply Officer
d. Borough Commander
The correct answer is: Chief of Operations
Question text
- Which point is correct regarding hydrant inspection duty?
Select one:
a. An officer, or acting officer and not less than 2 firefighters, exclusive of the chauffeur, shall perform inspectional duty
b. Hydrant inspection duty shall be performed between 1000-1600 hours
c. If a unit does not perform hydrant inspection duty as per their schedule, they shall promptly notify the Deputy Chief, Battalion Chief and dispatcher by telephone
d. Relocated companies shall perform hydrant inspection duty when relocated for the day tour
Feedback
(28.2.2, 28.2.8, 28.2.9) And not less than 3 FF’s, between 0930-1700 hours, Relocated companies shall NOT perform)
The correct answer is: If a unit does not perform hydrant inspection duty as per their schedule, they shall promptly notify the Deputy Chief, Battalion Chief and dispatcher by telephone
Question text
- Which point is incorrect regarding the wearing of uniform shorts?
Select one:
a. Shorts are an optional part of the uniform year round
b. Shorts shall not be worn for BISP, Complaint investigation, Annual Education Day, or Public Education activities
c. Units may wear shorts when called to the Bureau of Training and Satellite training locations
d. Shorts may be worn for hydrant inspection
Feedback
(Regs 29.6.4) (Shorts may NOT be worn for hydrant inspection)
The correct answer is: Shorts may be worn for hydrant inspection
- At a fire in a H-type multiple dwelling where two floors are involved, it is generally necessary to transmit which signal below?
Select one:
a. 4th alarm
b. 3rd alarm
c. Extra engine and truck
d. 2nd alarm
Feedback
(MD 5.5.2)
The correct answer is: 2nd alarm
Question text
- In a HRFPMD, ventilation of the fire apartment should take place after the main body of fire has been ______. The attack stairway will be the primary means for vertical ventilation when the main body of fire has been ______. Doors to elevator machinery rooms at the roof level should not be used for ventilation until the fire is _______.
Select one:
a. Controlled; under control; knocked down
b. Controlled; knocked down; under control
c. Knocked down; under control; controlled
d. Knocked down; controlled; under control
The correct answer is: Controlled; knocked down; under control
Question text
- During fire operations in a HRPFMD, vertical ventilation shall only be performed when ordered by who?
Select one:
a. The IC or Fire Sector Supervisor
b. The IC or the Ladder Company Officer
c. The IC only
d. The Ladder Company Officer
The correct answer is: The IC only
- In a HRFPMD, ventilation of the fire apartment should take place after the main body of fire has been ______. The attack stairway will be the primary means for vertical ventilation when the main body of fire has been ______. Doors to elevator machinery rooms at the roof level should not be used for ventilation until the fire is _______.
Select one:
a. Controlled; under control; knocked down
b. Controlled; knocked down; under control
c. Knocked down; under control; controlled
d. Knocked down; controlled; under control
The correct answer is: Controlled; knocked down; under control
- At a fire in a H-type multiple dwelling where two floors are involved, it is generally necessary to transmit which signal below?
Select one:
a. 4th alarm
b. 3rd alarm
c. Extra engine and truck
d. 2nd alarm
The correct answer is: 2nd alarm
uestion text
- What is the most probable point for vertical fire extension in a H-Type multiple dwelling?
Select one:
a. Closets
b. Dumbwaiter shafts
c. Vertical steel channels
d. Pipe recesses
The correct answer is: Vertical steel channels
Question text
- Which point is incorrect regarding the wearing of uniform shorts?
Select one:
a. Shorts are an optional part of the uniform year round
b. Shorts shall not be worn for BISP, Complaint investigation, Annual Education Day, or Public Education activities
c. Units may wear shorts when called to the Bureau of Training and Satellite training locations
d. Shorts may be worn for hydrant inspection
Feedback
(Regs 29.6.4) (Shorts may NOT be worn for hydrant inspection)
The correct answer is: Shorts may be worn for hydrant inspection
- Which point is correct regarding hydrant inspection duty?
Select one:
a. An officer, or acting officer and not less than 2 firefighters, exclusive of the chauffeur, shall perform inspectional duty
b. Hydrant inspection duty shall be performed between 1000-1600 hours
c. If a unit does not perform hydrant inspection duty as per their schedule, they shall promptly notify the Deputy Chief, Battalion Chief and dispatcher by telephone
d. Relocated companies shall perform hydrant inspection duty when relocated for the day tour
Feedback
(28.2.2, 28.2.8, 28.2.9) And not less than 3 FF’s, between 0930-1700 hours, Relocated companies shall NOT perform)
The correct answer is: If a unit does not perform hydrant inspection duty as per their schedule, they shall promptly notify the Deputy Chief, Battalion Chief and dispatcher by telephone
Question text
- If an officer wishes to request the installation of a new hydrant, the request must be submitted in writing through the chain of command to the ________________?
Select one:
a. Division Commander
b. Chief of Operations
c. Brooklyn Boro Command Water Supply Officer
d. Borough Commander
The correct answer is: Chief of Operations
Question text
- If a commanding officer believes the unit’s hydrant inspection goals will not be met by the end of the inspection period, the officer should submit a letterhead report through the chain of command to the ________________ requesting assistance?
Select one:
a. Division Commander
b. Battalion Commander
c. Brooklyn Boro Command Water Supply Officer
d. Borough Commander
The correct answer is: Borough Commander
Question text
- You are a company officer on duty in Engine 200 where an EEO Compliance Inspection is taking place. In regards to this inspection, you would be incorrect to believe that?
Select one:
a. If a unit in a single house or both units in a double house receive an alarm during the EEO visit, the EEO staff will terminate the inspection and leave the premises
b. The unit(s) in the firehouse will remain in service during the inspection
c. When the inspection is complete, the EEO investigator will provide the officer with a signed copy of the EEO inspection checklist
d. After EEO announces their visit to the Housewatch FF, that FF should not make any notifications unless directed to do so by EEO personnel
Feedback
(Regs 20.3.10) (Housewatch FF notifies OOD that their presence is required at the housewatch area)
The correct answer is: After EEO announces their visit to the Housewatch FF, that FF should not make any notifications unless directed to do so by EEO personnel
Question text
- E43 and Ladder 59 arrive first at a compactor fire on the 15th floor of a 40-story High Rise Multiple Dwelling. Fire is burning at the compactor chute door on the 15th floor. In this situation, it would be correct to think Engine 43 should stretch?
Select one:
a. A 2 ½” line from the standpipe outlet to the 15th floor chute door to extinguish the fire
b. A 1 ¾” line from the standpipe outlet to the 16th floor chute door to extinguish the fire
c. A 1 ¾” line from the standpipe outlet to the 15th floor chute door to extinguish the fire
d. A 2 ½” from the standpipe outlet to the 16th floor chute door to extinguish the fire
Feedback
(Fires 7—8.2 A)
The correct answer is: A 2 ½” from the standpipe outlet to the 16th floor chute door to extinguish the fire
Question text
- In refuse chutes constructed in new buildings, sprinklers shall be provided?
Select one:
a. On every story for the height of the chute
b. Spaced not more than three stories apart for the height of the chute.
c. Spaced not more than two stories apart for the height of the chute
d. On every story for the height of the chute unless electrically operated
Feedback
(Fires 7—7.5)
The correct answer is: Spaced not more than two stories apart for the height of the chute