natural gas is primarily composed of what?
methane
is natural gas lighter than air?
yes
natural gas flashpoint?
1200F
natural gas flammable range?
4-14%
does natural gas dissipate rapidly outside?
yes
where does natural gas tend to pocket in buildings?
attics, dead spaces
should burning natural gas be extinguished?
not normally
natural gas fires should be controlled how?
stoping the flow of gas
what PPE will be required for responses to gas leaks?
full PPE
what should be established around any suspected gas leak?
hot zone
apparatus placement should be _____ of any potential vapor cloud.
upwind
if the leak is above ground and the officer feels like the leak can be controlled, what needs to be on the ground?
hand line
NAERG guideline for gas leak distance?
330ft in all directions
secure all _____ gas shutoff valves before attempting to locate the source of the gas and any other shutoff devices.
known
when a leak is inside the building, where should the gas be shut off?
at the meter
what will a meter possibly show if there is a gas leak?
spinning meter
what should command do with a meter until repairs are made?
red tag out of service
if there is any indication of gas accumulating inside the building, what needs to be done?
control ignition sources
do not shut down power from an outside breaker unless FD has what?
has the appropriate gas meter
personnel should ensure that blowers are not placed in an _______ enviroment.
explosive
if the gas company must excavate to fix a leak, what must FD have?
1 3/4 on the ground
in the event that there is equipment running in the area, what should you do?
leave them running
units arriving at an explosion must consider what as a cause?
natural gas
if a gas concentration is encountered inside, adjacent to, or underneath any building, what needs to be secured?
all ignition sources