Student Guide E-2 Flashcards

(19 cards)

1
Q

What signal will generate the SI in uncontrolled depress of all SG?

A

Low SG P 500 1/1 2 SG

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is long term recovery method?

A

Cooldown and depress

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What happens to heat transfer rate as Tavg lowers?

A

It lowers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the limiting challenge to the core?

A

PTS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

IF all SG are faulted can systems maintain SG lvl?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What will cause RCS P and PRZ lvl to rise?

A

ECCS flow exceeds RCS shrinkage rate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Why we control AFW flow during an uncontrolled depress of all SGs?

A

Prevent SG dryout minimize cooldown

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the minimum FW flow to the SGs when all faulted?

A

25K pph and keep them wet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What are entry conditions for ECA2.1

A

All SGs depressurized

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

E-2 Major Action

A

1) Establish secondary pressure (heat sink)
2) Control Feed flow (limit c/d, prevent sg overfill)
3) Terminate SI (ECCS maleup exceeds shrink)
4) Cooldown and Place RHR in service (heat sink)
5) Cooldown to cold shutdown (stop steam gen)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

ECA 2.1 What action if SG level rises?

A

E-3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

ECA 2.1 What actions if SG P rises?

A

Any SG pressure boundary restored

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Under what condition will the SI pump be stopped in ECA 2.1?

A

Meet SI termination and RCS pressure above SI pump shutoff head and rising

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Why are RCS temps checked prior to determining if RCPs should be stopped?

A

Ensure pressure reduction due to SG depressurization

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Why RCP 3 for spray?

A

Greatest spray flow due to greatest D/p from spray to surge line

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Basis for performing Att ! in ECA2.1

A

Close valves on one loop at a time to ensure local check

17
Q

What is purpose of looping back to step 2 in ECA 2.1 if ECCS flow cannot be terminated?

A

Control Cool down and recheck for primary to secondary leackage

18
Q

What actions of ECA2.1 will limit he RCS re pressurization following blowdown?

A

Control AFW to stabilize HL temp
Reduce ECCS
Establish LD

19
Q

If reducing AFW flow 25K pph in ECA 2.1 results in red path, what action should be taken?

A

Maintain the established flow rate unless HL temp are rising. Must go to FRP