1
Q

If SI is actuated during an ATWS, what is the only additional action the operators must take to ensure emergency boration?

A

Check RCS Pressure to ensure enough flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is a condition 2 event?

A

Event likely to occur but the plant will be able to be restarted. Will not cause consequential loss of fuel cladding or RCS FPBs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is a ATWS?

A

A common cause failure that prevents the control rods from being inserted in response to an aniticpated event

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

During an ATWS event, what would cause a challenge to the Fuel/Clad Fission Product Barrier?

A

Most limiting event is a LOOP. Fuel could reach DNB due to loss of forced flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

During an ATWS event, what would cause a challenge to the RCS Pressure Boundary Fission Product Barrier?

A

Events initiated by a significant reduction in FW flow = rapids RCS Temp rise or events which the design capabilities RCS will be exceeded

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

List possible sources of positive reactivity in ATWS analysis?

A

Rods do not insert / cannot be
Cooldown from secondary
Dilution

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Describe a Nuclear Generation Event?

A

Power generation - power removal mismatch

1) Loss of Load/Turbine Trip
2) Loss of Normal Feedwater
3) Loss of Offsite Power
4) Accidental RCS Depressurization
5) Uncontrolled RCCA Bank Withdrawal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

List the FRS.1 immediate action steps and the basis:

A

Check Rx Trip - only RCP / Decay Heat

Actuate AMSAC - Turbine Tripped and AFW in service

Check TT - prevent uncontrolled cooldown. Turbine needs to be tripped within 30s to maintain SG

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

List major actions of FRS.1

A

Verify Auto Actions
Emergency Borate
Check for positive sources of reactivity
Verify subcritical

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the basis for checking RCS pressure below PORV lift setpoint?

A

Ensure ECCS can inject and provide boration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What condition must be satisfied to exit FRS.1?

A

<5% log power and -SUR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What are the two causes of loss of subcriticality that FRS.1 will evaluate?

A

Cooldown

Dilution

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the minimum AFW flowrate for adequate heat removal during ATWS?

A

450K pph

How well did you know this?
1
Not at all
2
3
4
5
Perfectly