Test 1 Flashcards

(49 cards)

1
Q

What type of vacuum breaker is used where there is no back pressure downstream, but a valve is installed downstream of the vacuum breaker.
A. Atmospheric
B. Pressure
C. Hose
D. All could be used

A

B. Pressure

Page 42
Section 603.3.6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A 2-inch Trap (arm) may be located____ from a vent?

A. 42”
B. 48”
C. 54”
D. 60

A

D. 60”

Section 1002.2
Page 85

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When a rough plumbing air test is done,the test procedure shall be____?
A. 5 psi for 15 min
B. 5 psi for the period required inspection
C. 1” of water column for the period of required inspection.
D. Either A or C may be used at the request of the inspector.

A

A. 5 psi for 15 minutes

Section 712.3

Page 72

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Distance between the trap and vent on a water closet with a 4” trap arm will not be more than____?
A. 4’
B.6’
C.8’
D.5’

A

B.6’

Section 1102.2 ft note

Page 85

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
  1. Application for a plumbing license is made to

A. State health department
B. Commissioner of health
C. MN Plumbing Department
D. Department of Labor and Industry

A

D. Department of Labor and Industry

417.16

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
  1. A test and inspection tag must be affixed to an RPZ after it’s been tested?
    A.True
    B. false
A

A. True

603.5.23.3
Pg 48

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
  1. What type of urinal is prohibited?
    A. Blowout
    B. Wall-hung pedestal
    C. Siphon jet
    D. Trough
A

D. Trough

405.2 pg 30

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q
  1. The waste pipe for a commercial food disposal must not be less than ____?
    A. 1 1/2 “
    B. 2”
    C. 2 1/2”
    D. 3”
A

B. 2”

Table 702.1
Footnote 2 ph 65

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
  1. Any pipe making and angel of less than 45 degrees with the horizontal is called a vertical pipe.
    A. True
    B. False
A

B. False

224.0 pg 20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q
  1. Can a vent from a chemical waste tie into a waste from a bathroom?
    A. Yes
    B. No
A

B. No

811.6 ph 79

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q
  1. What is the minimum size pipe for an underground drain?
    A. 1 1/2”
    B. 1 1/4”
    C. 2”
    D. 3”
A

B. 1 1/4”

703.2 pg 67

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q
  1. Cleanouts for a 4” pipe shall be located ______ ft apart
    A. 50’
    B. 100’
    C. 150’
    D. 200’
A

B. 100’

707.4 pg 70

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q
  1. Are saddle hubs permissible inside of the drainage system?
    A. Yes
    B. No
A

B. No

310.1 pg 23

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q
  1. The rough plumbing shall be air tested at the uniform pressure of ____?
    A. 5 lbs for 10 min
    B. 5 lbs for 15 mins, or duration
    C. 10 lbs for 15 min
    D. 5 lbs for min
A

B. 5 lbs for 15 min or duration

712.3 pg 72

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q
  1. A 6” clean out is needed on a 6” sewer line before reducing pipe size
    A. True
    B. False
A

B. False

Table 708.1 pg 70

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q
  1. A water closet shall be installed so that____.
    A.the center line is no less than 15” from any side wall.
    B. The top of the seat is not over 2” above the rim of the fixture.
    C. At least 24” of clearance must be provided in front of water closets
    D. Both A and C may are correct.
A

D. Both A and C are correct.

Section 402.5

Page 29

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q
  1. The minimum size building water service is ____?
    A. 1”
    B. 3/4
    C. 1 1/4”
    D. Whatever the city required
A

B. 3/4”

Table 610.7
Footnote of 58

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q
  1. The maximum vertical distance from a fixture to the trap weir is ____?
    A. 10”
    B. 24 “
    C. 18“
    D. 20”
A

B. 24”

1001.1 pg 85

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q
  1. Does a residential (R-3) dwelling boiler require an RPZ?
    A. Yes
    B. No
A

B. No

603.5.10 pg 47

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q
  1. The finished plumbing shall be tested at a pressure equal to ___?
    A. 1” per static pressure
    B. 1 lb per square inch
    C. 5 lb
    D. 1” water column
A

D. 1” water column

712.5 pg 72

21
Q
  1. Any licenses who does not renew within ____ is no longer eligible for renewal?
    A. 2 years
    B. 3 years
    C. 4 years
    D. 5 years
A

A. 2 years

4716.0040 pg 174

22
Q
  1. A plumber must be licensed to work is cities with a population over ____?
    A. 500
    B. 10,000
    C. 1000
    D. 5000
A

D. 5000

326b.475 pg 199

23
Q
  1. How high above the flood rim level of the fixture can an offset occur using a 90 degree elbow?
    A. 2”
    B. 4”
    C. 6”
    D. 2 times the diameter
A

C. 6”

905.3 pg 81

24
Q
  1. Is it permissible to use a 1 1/2” combination T.Y. Fitting in the vertical pickup of a 3’ trap arm with a 1 1/2” trap?
    A. Yes
    B. No
A

B. No

905.2 pg 81

25
26. The minimum length of a clothes washer standpipe is ____? A. 16” B. 24” C. 18” D. 30”
C. 18” 804.1 pg 78
26
27. The vertical distance from the crown weir and top dip of the trap is ____? A. 3 to 5 inches B. 1 1/2 to 3 1/2 inches C. 2 to 4 inches D. Per mfg instructions
C. 2 to 4 inches 1005.1 pg 86
27
28. New RPZ installations must be at least ____ but not more than ____ above the finished floor ground level. A. 12” to 6’ B. 12” to 5’ C. 18” to 7’ D. 12” to 5.6’
B. 12” to 5’ 603.4.3 pg 45
28
29. A carbonated beverage machine cannot have copper tubing in the system downstream of the back flow preventer. A. True B. False
A. True 603.5.12 pg 47
29
30. The diameter of a waste and overflow for a bathtub must not be less than ____ inches? A. 1 1/4 B. 2 C. 1 1/2 D. Both A and B
C. 1 1/2 702.1 pg 65
30
31. The minimum gallons per minute discharge capacity of a sewage pump servicing water closets or urinals is not less than____gpm? A. 10 gpm B. 15 gpm C. 20 gpm D. 25 gpm
C. 20 gpm 710.3 ft 1 pg 71
31
32. Primer must comply with ASTM standard number ____? A. 13 B. 14 C. F-656 D. None of the above
C. F-656 B 605.12.2 pg 54, 68
32
33. What is the minimum air gap required for a drinking fountain when not affected by a nearby wall? A. 1 1/2” B. 2” C. 1” D. None of the above
C. 1” 603.3.3 pg 45
33
34. Plastic waste piping passing through studs or plates shall be protected the same as required for copper tubing A. True B. False
A. True 312.9 pg 24
34
35. The minimum size vent that can be installed in any plumbing system is 1 1/2” A. True B. False
B. False 703.2 pg 67
35
36. How many fixtures located in the same room can be supplied with a 1/2” water pipe? A. 3 B. 2 C. 4 D. Size per chart
610.4 pg 61
36
37. A transition coupling without a shield may be used above ground level. A. True B. False
B. False 705.10 pg 69
37
38. The orifice of the jet in a drinking fountain must be at least ____ inches above the rim of the basin. A. 1” B. 1/2” C. 1 1/2” D. 1/4”
A. 1” Table 603.2 pg 43
38
39. Solvent weld joints in PVC pipe must include applying contrasting color to the pipe and the fitting. A. True B. False
A. True 605.12.2 pg 54 705.6.2 of 68
39
40. What is the minimum pitch of a 2” pipe to be maintained on a horizontal fixture branch? A. 1/4” B. 1/16” C. 1/8” D. 1/2”
A. 1/4” 708.1 pg 70
40
41. The discharge pipe from a relief valve shall be full size and run within _____inches of the floor or safe place of disposal. A. 12 inches B. 10 inches C. 15 inches D. 18 inches
D. 18 inches 608.5 pg 56
41
42. The stand pipe for clothes washer shall: A. Have the trap installed at least 6” above the floor B. Have a minimum trap size of 1 1/2” C. Be a maximum of 30” long D. All of the above are correct E. Only A and C are correct
E: only A and C are correct 804.1 pg 78
42
43. All pipes passing through of in contact with cinder, concrete, or other corrosive materials shall be protected against external corrosion by protective coating, wrap, or other means. A. True B. False
A. True 312.16 pg 24
43
44. Indirect waste connections shall be provided for the drains, overflows and relief vents from the waste distribution system by means of ___? A. An indirect waste B. An air break C. An air gap D. B and C
D. Both B and C, an air gap and air break 801.4 pg 77
44
45. The distance between cleanouts shall not exceed ____? A. 50’ horizontal for all pipes 3” or less B. 100’ horizontal for all pipe C. 50’ horizontal and vertical for all pipes 3” or less D. Both A and B correct
B. 100’ horizontal for all pipe 706.4 pg 70
45
46. Water meters shall be placed at least ____ inches above the finished floor. A. 6” B. 8” C. 10” D. 12”
D. 12” 609.12 pg 57
46
47. Commercial food waste grinders shall discharge to a grease interceptor. A. True B. False
B. False 1014.1.3 pg 87
47
48. What type of material is not permitted for the waste piping of a urinal? A. Plastic B.copper/drawn brass C. Steel D. Cast iron
B. Copper/drawn brass 402.6. Pg 29
48
49. The maximum of one approved slip joint fitting shall be permitted on the ____ side with an approved trap adapter. A. Inlet B. Both inlet and outlet C. Outlet D. Only on p-traps
C. Outlet 49 1003.2 Pg 85
49
50. The underground water service and building drain or sewer shall not be less than ____ feee apart horizontally, if separated by contaminated soil. A. 5 feet B. 6 feee C. 10 feet D. By administration authority
C. 10 feet 609.6.1 pg 57