What type of vacuum breaker is used where there is no back pressure downstream, but a valve is installed downstream of the vacuum breaker.
A. Atmospheric
B. Pressure
C. Hose
D. All could be used
B. Pressure
Page 42
Section 603.3.6
A 2-inch Trap (arm) may be located____ from a vent?
A. 42”
B. 48”
C. 54”
D. 60
D. 60”
Section 1002.2
Page 85
When a rough plumbing air test is done,the test procedure shall be____?
A. 5 psi for 15 min
B. 5 psi for the period required inspection
C. 1” of water column for the period of required inspection.
D. Either A or C may be used at the request of the inspector.
A. 5 psi for 15 minutes
Section 712.3
Page 72
Distance between the trap and vent on a water closet with a 4” trap arm will not be more than____?
A. 4’
B.6’
C.8’
D.5’
B.6’
Section 1102.2 ft note
Page 85
- Application for a plumbing license is made to
A. State health department
B. Commissioner of health
C. MN Plumbing Department
D. Department of Labor and Industry
D. Department of Labor and Industry
417.16
- A test and inspection tag must be affixed to an RPZ after it’s been tested?
A.True
B. false
A. True
603.5.23.3
Pg 48
- What type of urinal is prohibited?
A. Blowout
B. Wall-hung pedestal
C. Siphon jet
D. Trough
D. Trough
405.2 pg 30
- The waste pipe for a commercial food disposal must not be less than ____?
A. 1 1/2 “
B. 2”
C. 2 1/2”
D. 3”
B. 2”
Table 702.1
Footnote 2 ph 65
- Any pipe making and angel of less than 45 degrees with the horizontal is called a vertical pipe.
A. True
B. False
B. False
224.0 pg 20
- Can a vent from a chemical waste tie into a waste from a bathroom?
A. Yes
B. No
B. No
811.6 ph 79
- What is the minimum size pipe for an underground drain?
A. 1 1/2”
B. 1 1/4”
C. 2”
D. 3”
B. 1 1/4”
703.2 pg 67
- Cleanouts for a 4” pipe shall be located ______ ft apart
A. 50’
B. 100’
C. 150’
D. 200’
B. 100’
707.4 pg 70
- Are saddle hubs permissible inside of the drainage system?
A. Yes
B. No
B. No
310.1 pg 23
- The rough plumbing shall be air tested at the uniform pressure of ____?
A. 5 lbs for 10 min
B. 5 lbs for 15 mins, or duration
C. 10 lbs for 15 min
D. 5 lbs for min
B. 5 lbs for 15 min or duration
712.3 pg 72
- A 6” clean out is needed on a 6” sewer line before reducing pipe size
A. True
B. False
B. False
Table 708.1 pg 70
- A water closet shall be installed so that____.
A.the center line is no less than 15” from any side wall.
B. The top of the seat is not over 2” above the rim of the fixture.
C. At least 24” of clearance must be provided in front of water closets
D. Both A and C may are correct.
D. Both A and C are correct.
Section 402.5
Page 29
- The minimum size building water service is ____?
A. 1”
B. 3/4
C. 1 1/4”
D. Whatever the city required
B. 3/4”
Table 610.7
Footnote of 58
- The maximum vertical distance from a fixture to the trap weir is ____?
A. 10”
B. 24 “
C. 18“
D. 20”
B. 24”
1001.1 pg 85
- Does a residential (R-3) dwelling boiler require an RPZ?
A. Yes
B. No
B. No
603.5.10 pg 47
- The finished plumbing shall be tested at a pressure equal to ___?
A. 1” per static pressure
B. 1 lb per square inch
C. 5 lb
D. 1” water column
D. 1” water column
712.5 pg 72
- Any licenses who does not renew within ____ is no longer eligible for renewal?
A. 2 years
B. 3 years
C. 4 years
D. 5 years
A. 2 years
4716.0040 pg 174
- A plumber must be licensed to work is cities with a population over ____?
A. 500
B. 10,000
C. 1000
D. 5000
D. 5000
326b.475 pg 199
- How high above the flood rim level of the fixture can an offset occur using a 90 degree elbow?
A. 2”
B. 4”
C. 6”
D. 2 times the diameter
C. 6”
905.3 pg 81
- Is it permissible to use a 1 1/2” combination T.Y. Fitting in the vertical pickup of a 3’ trap arm with a 1 1/2” trap?
A. Yes
B. No
B. No
905.2 pg 81