- If a building is condemned by the administrative authority due to unsanitary conditions of plumbing system, any alterations will not be considered repairs, but new plumbing.
A. True
B. False
A. True
1300.01.8 pg 189
- The expiration date of Journeyman and Master licenses is _____ (month/day) each year.
Decmeber 31st
CS pg 174
- A backflow preventer must not be installed in a pit
A. True
B. False
A. True
603.4.9 pg 45
- A single trap may serve two or three compartment sinks or laundry trays. The trap shall be located no more than ____ inches from each compartment outlet.
A. 24 inches
B. 36 inches
C. 30 inches
D. 32 inches
C. 30 inches
1011.2 pg 85
- The rough plumbing of a building may be closed in after it has been:
A. Inspected and approved
B. Permits have been taken out
C. Plans were submitted
D. Inspected, tested and approved
D. Inspected, tested and approved
1300.02
Sub 3
Pg 191
- No water closet or similar fixture shall be in a room without adequate lighting and ventilation.
A.true
B. False
A. True
1002.4 pg 85
- Except for water closets and similar fixtures, the trap arm connection cannot be made with a fitting that will make the connection to the vent lower than the trap weir.
A. True
B. False
A. True
4714.01 table
Pg 3
- When plastic pipe is used for underground waste, you must …
A. Limit the run to 35 feet
B. Pressure test it to a minimum of 10 psi for 5 minutes
C. Lay it in a continuous granular bed
D. All of the above are correct
C. Lay it in a continuous granular bed
313.5 pg 24
- What is the maximum trap arm length permitted for a 3 inch trap?
A. 5 feet
B. 6 feet
C. 4 inches
D. 3 feet, 6 inches
B. 6 feet
1002.2 pg 85
- What is the minimum slope of a 3 inch pipe?
A. 1/4 inch
B. 1/16 inch
C. 1/8 inch
D. Depends on the depth of sewer
A. 1/4 inch slope
708.1 70. (73)
- How frequently must an RPZ be inspected?
A. 5 years
B. Depends on the size of the RPZ
C. 6 months
D. 1 year
D. 1 year
703.5.23.2. Pg 48
- How many 90 degree elbows may be used to change the direction of a trap arm without using a c/o?
A. 1
B. 2
C. 3
D. As many as needed
A. 1
1002.3 pg 85
A four by three water closet connection will not count as a reduction in pipe size.
True or false
True
310.5 pg 23
Vertical piping of plastic pipe, 2” and over, shall be supported every _____ intervals.
A. 5 foot intervals
B. 8 foot intervals
C. 4 foot intervals
D. At each story
D. At each story
313.3 pg 27
A new shower or shower/bath combination must be installed with an anti scald type control valve. True or false
True
408.3 pg 31
One drainage fixture unit is equal to _____ gallons per minute of discharge.
A. 7 1/2
B. 6
C. 8 1/2
D. 7
A. 7 1/2
702.2 pg 65-66
How far away must a vent be located horizontally from a window?
A. 5 ft
B. 10 ft
C. 12 ft
B. 10 ft
906.2 pg 82
Sinks, or other fixtures served by grease interceptors shall be individually trapped. True or false.
A. True
1014.1.1 pg 87
If commercial building discharges sewage with a pump duplicate pumping equipment is required. True or false
True
710.9. Pg 71
Hot water supply systems in ____ story buildings or where the developed length is more than ____ feet, require a hot water circulating pump.
A. 4 stories/100 feet
B. 3 stories/150 feet
C. No requirement
A. 4 stories, 100 feet
601.2.2 pg 41
An approved pressure reducing valve shall be installed in the water service pipe near the building if the street main exceeds ____psi.
A. 60 psi
B. 75 psi
C. 70 psi
D. 80 psi
D. 80 psi
608.2
Pg 55
Is it permissible to waste 4 water closets in a horizontal branch,
Yes or no
Yes
703.2, footnote 4, pg 60
The minimum size branch to a hose Bibb or sill cock shall be______inch(es).
A. 1/2 inch
B. 1 inch
C. 3/4 inch
D. Depends on size of valve
A. 1/2 inch
Chart 610.3
Pg 60
Who is responsible for furnishing the equipment, materials, power and labor necessary for the plumbing tear and inspection?
A. Homeowner
B. General contractor
C. Plumbing contractor
D. Wholesale house
C. Plumbing contractor
1300.021 sub 4