Test 3 Flashcards
(51 cards)
- Water meters shall be placed at least____ inches above above basement floor.
A. 18
B.12
C.16
D.24
B. 12 inches
section 609.12
pg 57
A domestic dishwasher machine may be directly connected to a drainage system or food waste disposal using an approved _____ on the discharge side of the dishwashing machine through a tailpiece upstream of the trap.
A. air break
B. air gap
C. Air gap Fitting
D. Non of the above
C. Air gap fitting
807.3
78
Plastic waste pipe passing through studs shall be protected with a nail plates, the same as required for copper tubing.
A. True
B.False
A. True
312.9
24
For controlled flow roof drainage that water from a 25 year frequency storm shall not be stored on the roof more than ___ hours .
A. 8
B. 12
C. 24
D.36
C. 24
1105.1
93
Indirect waste connections shall be provided for drains, overflows or relief vents from the waste distribution system by means of______.
A. an indirect waste.
B. an Air break
C. an air gap
D. a backflow preventer
C. an air gap
801.5
77
When constructing a sump tank, the minimum thickness of the concrete sump wall and floor is____.
A. 2inches
B. 3inches
C. 4inches
D. 6inches
C. 4 inches
810.2
78
Master and Journeyman license expire on December 31st.
A.true
B.false
A. true
36B.458
203 or 207
The maximum developed length of an indirect waste pipe is _____ feet.
A. 5
B. 10
C. 15
D. 20
C. 15 ft
801.3.1
77
Stacks receiving discharge of less than____ stories of plumbing fixtures do not need suds relief.
A. 2
B. 3
C. 4
D. 5
B. 3 stories
711.1 (2)
72
- Replacement of the existing building sewer and storm sewer using _____ pipelining trenchless methodology shall be installed in accordance with Astm-1216.
A. cured in place
B. orangberg
C. fiberglass
D. cast iron
A. Cured in place.
715.3
73
- All pipes passing through or in contact with cinder, concrete or other corrosive materials shall be protected against external corrosion by protective coating, wrapping or other resistant means.
A. true
B. false
A. True
312.1
23
- A shower or Shower/bath combination must be installed with an anti scaled control valve (Asse 1016)
A.True
B.False
A.True
408.3
31
- How far must a vent terminal be located horizontally from a window?
A. 5 feet
B. 10 Feet
C. 12 Feet
D. 3 feet
B. 10 feet
906.2
82
- A vent from an indirect waste pipe shall combine with sewer connected vent.
A. True
B. False
B. False
803.3
77
- All food and beverages and storage or preparation that requires drainage shall be provided with _____ piping for the equipment as required.
A. direct
B. indirect
C. Trapped
D. str
B. indirect
801.3
77
- Indirect waste piping shall discharge in the building drainage system through_____.
A. air Gap
B. Air break
C. Air gap Device
D. Both A and B
D. both A and B
Air gap and air break
801.2
77
- Sinks or other fixtures served by grease interceptors shall be trapped.
A. true
B.false
A.true
1014.1.1
87
- When commercial buildings discharge sewage by pump, duplicate pumping equipment is required.
A. True
B. False
A.True
814.6
80
- Condensate waste from air conditioning coils will discharge, by direct connection, to a lavatory tailpiece or an approved accessible inlet on a bathtub overflow.
A. true
B. false
a. True
814.6
80
- A domestic or culinary sink may be used as a receptor for an indirect waste pipe.
A. true
B. false
B.false
804.2
78
21.No indirect waste receptor shall be installed in a toilet room, Closet cupboard or storeroom not in general use by the occupants of the building.
A.true
B.false
a. True
804.1
78
- Two fixtures shall be permitted to be served by a common vertical pipe where each fixture wastes separately to a(n) ______,having inlet openings at the same level.
A.double sanitary tee
B. Double wye fitting
C. Sanitary cross
D. Approved double fixture fitting
D. Approved double fixture fitting
905.6 pg 82
704.2 pg 66
- Each waste pipe receiving the discharge of a fixture, in which acid or corrosive chemical is placed, shall be constructed of_____.
A. Chlorinated polyvinyl chloride
B. High silicone iron pipe
C. Polyvinylidene fluoride PVDF
D. All of the above
D. All of the above are correct
811.2 pg 79
- Not more than _____ of the total permitted vent length shall be installed in a horizontal position.
A. One quarter
B. One half
C. One third
D. Two thirds
C. One third
No more than 1/3 vent length shall be installed in a horizontal position
904.2 pg 81