Test 5 Flashcards
(49 cards)
- Macerating toilet system is a system comprised of a sump with macerating pump connection for a water closet and other plumbing fixture in single bathrooms, true or false.
True
710.13 page 72
219 page 15
True or false. No plumbing sewer system shall be located in a lot other than the lot owned by the building or premises.
True
307.1 page 23
A rainwater catchment system collects and stores water from___collection surfaces
A. Parking lots.
B. Grassy berms.
C. Percolation pits.
D. Above ground.
Above ground
Pg 109
The minimum slip joint access panel shall be___inches, and so arranged without obstructions as to make ready for inspections and repair.
A. 6
B. 8
C. 10
D. 12
D. 12 inches
402.2.10
What is the maximum trap arm length permitted for a 3 inch trap?
A. 5 ft
B. 6 ft
C. 3 ft 6 inches
D. 4 inches
B. 6 ft
Table
1002.2 pg 85
Townhouse utilities may be combined inside the building and distributed to each unit
true or false
False
606.3 pg 55
Plumbing systems in a moved structure___be completely tested as new work.
A.must
B. Shall
C. Will
Shall
(Stupid question). It should be a true false and the answer is true.
An additional relief vent is required in combination, waste and vent systems when the piping exceeds___feet in length.
A. 25.
B. 50.
C. 100.
D. Not required.
C. 100 feet.
907.1 page 82
Unapproved pressure reducing valve shall be installed in the water service pipe near the building if the street main pressure exceeds___PSI.
A. 60.
B. 75.
C. 70.
D. 80.
D. 80.
608.2 page 55
Minimum pipe size for a symphonic roof drain is under___inches.
A. 1 1/2
B. 2
C. 3
D. 4
A. 1 1/2 inch
1106.2.5 page 94
Plumbing___be installed with due regard to preservation of the strength of structural members.
A. Shall
B. Doesn’t need to
C. Should
D. All of the above
Shall
4714.1. 3
A rain leader serving a roof area of 2210 would require a vertical pipe___inches in size.
A. 3
B. 4
C. 6
D. 8
B. 4
1103.1 pg 96
Building storm sewer shall be tested in accordance with section 712 or the hydrostatic test method. True or false.
True
1107.2.3 page 95
True or false. Copper shoulder joints do not require the steps of cleaning if you use self cleaning flux.
False
605.1.4 page 51
True or false. The provisions of the code shall be deemed to require a change in a portion of the plumbing drainage system or other regulated by the code in or on an existing building.
True
4714.0100 sub 6, page 5?
Proper protection shall be provided to prevent contamination of food by backflow of___.
A. air
B. Sterile goods
C. Sewage
D. Gas
C. Sewage
4714.00100 (B) pg 3
Sizing siphonic roof drains shall be based on a minimum rainfall rate of___inches per hour.
A. 2
B. 3
C. 4
D. 5
C. 4 inches of rain per hr
1106.2.1
If the authority having jurisdiction finds the full performance of bringing the existing work to compliance with the requirements of the code would result in exception or undue hardship, a___may be granted.
A. Deviation.
B. Alteration.
C. Exception.
D. All of the above.
Deviation 4714.0101 sub 3 page 5
No water closet or similar fixture shall be located in a room that is not___
A. Full sized
B. Properly shaped
C. Lighted and ventilated.
Lighted and ventilated
4714.01 table page 3
Anytime an individual drain exceeds___feet in length on a combination waste and vent system it shall be vented.
A. 15
B. 20
C. 25
D. 50
A.15
Any drain exceeding 15 feet in length on a combination waste-vent system shall be vented
910.3 page 83
The minimum height of a sewer below grade is ____ft.
1 foot is the minimum height of a sewer low-grade
312.3 page 24
True or false. Battery vented toilets may continue to remain in service as long as no alteration is made to the plumbing system under the provisions of the Minnesota UPC.
True
911.1 page 83
The building sewer in every building with installed plumbing fixtures shall be connected to the public sewer if available.
True,
4714.0101 sub 6 pg 5
No permit is required for the clearing of stoppage, including the removal and reinstallation of water closets. True or false.
True no permit is required for the clearing of stoppage or removal of water closets, or reinstallation of water closets