6/5 ENGINE COMPANY Flashcards

(43 cards)

1
Q

Hose used in the field comes in 50-foot sections, but may be shortened during repairs. The exception to this is the ______.

A

3”’ ladderpipe hose which comes in 100-foot sections

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

No section, however, will be issued for fire fighting use if it has been shortened to less than ____.

A

40 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Lengths of hose less than 40 feet may be used as ____.

A

bypasses or suction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Fire hose is of three types:

1.

A

100% polyester single or double jacketed, rubber lined, presently the standard for our Department.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Fire hose is of three types:

2.

A

3/4” garden hose

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Fire hose is of three types:

3.

A

Single jacketed, synthetic rubber, impregnated with synthetic fibers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

100% polyester hose is _____, however, it is important that dirty, wet hose be properly cleaned and dried.

A

mildew proof

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Fabric-jacketed hose shall be removed from apparatus and replaced with clean, dry hose at least _____.

A

once each three calendar months

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Firefighting hand lines shall be changed within ______ .

A

24 hours when damp or dirty

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Fabric jacketed supply lines shall be changed _____.

A

weekly or more frequently if damp or dirty

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Make proper entries in ___, _____,____, and ____. When doing hose change.

A

F-2 (Journal), Book 55, F-122 (Overlay Form) and F-128.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Dirty hose, suctions and bypasses shall be washed with ______.

A

clear, cold water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Heavily soiled hose may be washed using a ____ solution of concentrated liquid soap.

A

5 to 10%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Station Commanders shall contact the _____ for instructions regarding hose contaminated with substances which cannot be removed with clear, cold water and 5 to 10% soap solution.

A

Equipment Engineering Officer at Supply and Maintenance Division

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Hose shall be repaired by ___.

A

Supply and Maintenance Division

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Damaged hose forwarded to Supply and Maintenance Division for repair shall be ____.

A

clean, dry, rolled, and tied in two places

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Small burns in the outer jacket do ____ constitute damaged hose.

A

not

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Before sending in for replacement or repair, ___ as per Volume 3, 6/11- 25.60.

19
Q

If hose is determined to be in need of repair, mark damaged area by wrapping the hose with _____ where repairs are needed.

A

black tape at the location(s)

20
Q

Hose shall be rolled with the_____ forming the core, unless the female coupling needs repair. In that case, the ____ should form the core.

A

female coupling / male coupling

21
Q

New and repaired hose shall be tested _____ after receipt by the Station. Frequency: Hose shall be tested annually. Maximum period between tests shall be 12 months.

A

as soon as possible

22
Q

One-inch double jacketed hose shall be tested at ___

23
Q

All other rubber lined single and double jacketed hose, bypasses and soft suctions shall be tested at ___

24
Q

Testing procedure: Lay out hose from the pump outlet with ____. Attach shut-off butt.

A

no sharp kinks or bends, 300 feet maximum length at one outlet

25
Testing procedure: Open the shut-off and elevate _____.
above the level of the discharge gate
26
Annual Hose Test Record
F129
27
Female swivels should turn freely; if not, lubricate with graphite. Use of ____ is prohibited.
oil
28
The male end of a 1" hose should be folded back ____ from the coupling before starting the roll.
18 to 24 inches
29
Care must be taken any time hose streams are used from ladders. Horizontal movement of hose streams shall ____ in either direction from an "in-line" position with the beam and truss of ladders.
not exceed 15 degrees
30
If hose line is going to remain stationary for a period of time, form a loop approximately ___ with the nozzle, under the loop, towards fire. Secure hose line to loop with nylon strap approximately___ to allow nozzle movement,
10' in diameter / three feet back from nozzle
31
If it is desired to remove the entire nozzle assembly when extending the line, use the appropriate sized hose clamp, ____ , behind the shut-off, bleed the nozzle and remove.
6" to 12"
32
A built-up hydrant (BUFH) is assembled from a ___ pipe surmounted by an angle valve with a single 2-1/2" or 4" outlet.
4" to 6"
33
The 2-1/2" type built-up hydrant is used in areas having high water main pressure (___).
over 200 psi identified by red top
34
Subsurface hydrants (SSFH) are normally found on ___. They may have single or multiple outlets and are covered by____. These covers are usually painted yellow for identification.
airport property / heavy steel or cast-iron plates
35
A drafting connection consists of ____ having standard hose threads. These connections lead to non-pressurized sources of water.
6" pipe reduced to a 4" pipe
36
An Eddy Valve is a gate valve installed on a hydrant outlet for use by ____, etc. This valve permits repeated opening and closing of the hydrant without using the regular valve.
contractors
37
2-1/2" Angle Valves are connected on ___ hydrant and are for the use of other City departments for filling tanks, flushing streets, etc. They ____ by the Fire Department if other outlets are occupied or defective.
top of an existing / may be used
38
A __ issued by the Fire Department must be obtained before a private hydrant may be installed.
permit
39
Chattering in a hydrant is usually caused by a ___. A valve that is chattering should be immediately _____. These hydrants shall be reported for repair.
loose valve / closed or opened enough to stop the chattering
40
It is necessary to drain standpipes to the level of the outlet on the ____ before draining at the manifold to decrease the pressure so the clapper valve can be opened without damage.
second floor
41
Draining Dry Standpipes: 1. Open gate valve of ____ to admit air 2. Connect section of hose to _____; lower male to ground; open gate valve.
highest outlet / male outlet on second floor
42
Draining Dry Standpipes: 3. When water has drained to second floor outlet, open _____ at ground level to complete drainage. 4. After standpipe has been drained, disconnect hose. Close all gate valves; replace caps on male outlets, replace plugs in female inlets or replace breakable caps if available.
clapper valve with a hydrolator
43
F 122