T or F all lines at taxpayer fires must be 2 1/2
F. when medium or heavy fire conditions initial lines should be 2 1/2. 1 3/4 can be used in exposures
1st engine at a taxpayer fire cellar fire
into the occupancy above the fire. If there is an interior stair first line must be stretched to this point. advance down if possible
2nd line at taxpayer cellar fire
if interior stairs are present and 1st line advanced second line must be stretched to the top of the stairs
who ensures sprinkler is supplied at taxpayer fire
3rd engine
can second engine stretch a line at taxpayer fire
only if they supplied the sprinkler first and conditions permit
cockloft fire in a taxpayer where fire has control of cockloft and exposure protection is critical what should first engine do
position apparatus to utilize deck gun, consider inline pumping, save room for TL, if exposure problems stretch to most severe exposure
cockloft fire in a taxpayer where fire has control of cockloft and exposure protection is critical what should second engine do
assist first engine with stretch into exposure, or if conditions permit stretch second line into another exposed building/occupancy, may be advisable to skip stores
3rd engine at a cockloft fire in taxpayer
ensure sprinkler is supplied, stretch a line as ordered by the IC
who shuts utilities in a taxpayer fire
1st ladder company, if in the basement two masked members shall be disaptched
cellar fire in a taxpayer who brings first saw to the roof
2nd due roof
where do the 1st and 2nd due LCC go for cellar fire in a taxpayer
join forcible entry team unless directed otherwise
where do fires typically originate in taxpayer
street level in the storage or utility area in the rear
cellar fire in a taxpayer who do we need to communicate with in order to take store front windows
1st due truck officer
store fire in a taxpayer who authorizes removal of storefront windows
IC. charged line must be in place
who brings first saw to the roof at store fire in a taxpayer
first due roof
cockloft fire in a taxpayer where do the LCC’s go
1st LCC proceed to the roof, 2nd LCC join inside team or as directed
class J alarm between 1900-0700 who responds in emergency mode
1st due units
Class J alarm from 700-1900 who responds in emergency mode
its a single unit response between these hours and the company responds in emergency mode
is a manhole fire modified response for second due companies
no, manhole emergencies are
class J alarms how long does officer wait at the panel to make sure the reset holds
2-3 minutes
how many turns to shut the buckeye pipeline
42 full turns clockwise
In HRFPMD venting of the fire apartment should not take place until the fire is
controlled
elevator machinery room doors should not be used for ventilation until the fire
under control-as long as wind will not force smoke back into the building
in HRFPMD the FAST unit and CFRD engine shall be assigned to the fire sector when the fire is above what floor
fires above the sixth floor they can be staged on the floor below the fire, for fires sixth floor and below IC determines the location they will stage