PLUMBING CODE I Flashcards

(89 cards)

1
Q

Preferred when a piece of pipe needed is shorter than 150 cm long

A. Single Hub
B. Standard Pipe
C. Hubless Pipe
D. Double Hub

A

Correct answer: Double Hub
Source: PDE by Max Fajardo

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

used for a well-fitted hub and spigot connections

A

Standard pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

recommended when the length of a pipe needed is more than 150 cm long wherein cutting is not necessary

A

Single Hub

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

used in lieu of the single hub to do away with caulking of joints

A

Hubless pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Each member of the board, shall at the time of his appointment be at least _____ of age.

A. 21
B. 30
C. 35
D. 40

A

Correct answer: 30
Source: IRR of RA 1378

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Trap arm size of Laundry Tub

A. 38 mm
B. 32 mm
C. 51 mm
D. 76 mm

A

Correct answer: 38 mm
Source: RNPCP, Chapter 7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

trap arm size of wash basin (lavatory) single, dental units or cuspidor

A

32 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

trap arm size of floor drains, grease interceptors, showers, etc.

A

51 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

trap arm size of water closet

A

76 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

trap arm size of DRINKING FOUNTAIN

A

31 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the accreditation number of NAMPAP?

A. 12
B. 6
C. 4
D. 14

A

D. 14

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

A plumbing permit shall become null and void if the plumbing work has been suspended or abandoned for a period or _____.

A. 365 days
B. 90 days
C. 120 days
D. 360 days

A

C. 120 days

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The Plumbing Code has been in existence for almost _____ since its promulgation before it has been amended.

A. 40 years
B. 30 years
C. 50 years
D. 60 years

A

Correct answer: 40 years

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

promulgation and approval by Malacanang

A

January 28, 1959

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

President Estrada’s approval to the Revised Plumbing Code of 1999

A

December 21, 1999

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

An adjustable tubing connection, consisting of a compression nut, a friction ring, and a compression washer, designed to fit a threaded adapter fitting or a standard taper pipe thread.

A. Pressure-Lock Type Fitting
B. Slip Joint
C. Welded Joint or Seam
D. Shielded Coupling

A

B. Slip Joint

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Roughing-in of cold and hot water supply line are ideally distanced at least _____ apart.

A. 2”
B. 8”
C. 10”
D. 4”

A

Correct answer: 8”
Source: nachi.org; audel; aspe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What is not included in a plumbing unit?

A. Hose Bibb
B. Urinal
C. Laundry Tray
D. Kitchen Sink

A

B. Urinal

Note: Study both the Plumbing Unit of Revised National Plumbing Code of the Philippines (RNPCP) and National Building Code of the Philippines (NBCP).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Each fixture directly connected to the drainage system shall be equipped with a _____.

A. gas-tight p-trap
B. water-tight trap
C. water-sealed trap
D. approved crown trap

A

Correct answer: water-sealed trap (Principle no. 10)
Source: Basic Principles

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

IPS shall be supported at ___ intervals for piping 19 mm diameter and smaller.

A. 1.8 m
B. 3 m
C. 3.6 m
D. 1.2 m

A

Correct answer: 3.0 m
Source: RNPCP, Chapter 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

for IPS piping 25 mm and larger, support intervals shall be _______meters

A

3.6 m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Code on Sanitation of the Philippines

A. RA 8495
B. PD 856
C. RA 8749
D. RA 9514

A

Correct answer: PD 856

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Fire Code of the Philippines

A

RA 9514

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Philippine Clean Air Act

A

RA 8749

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Philippine Mechanical Engineering Act of 1998
RA 8495
26
A pipe flange that is not drilled for bolt holes. A. blind flange B. blank flange C. flat-face flange D. raised-face flange
B. blank flange
27
ASTM means? A. American Society for Testing and Materials B. American Standards for Testing and Materials C. American Safety Test Manuals D. American Society of Testing and Maintenance
A. American Society for Testing and Materials
28
Copper tube for water supply piping shall have a weight of not less than _____. A. Type K B. Type M C. Type L D. Type DWV
Type L
29
For caulked-on closet ring, the minimum overall depth shall be: A. 3" B. 1-1/2" C. 2" D. 1-1/4"
Correct answer: 2" or 51 mm Source: Chapter 4 Caulked-on closet rings or closet flanges shall not be less than 6.4 mm thick
30
This examination subject in Master Plumbing was originally split into two. A. Practical Problems B. Plumbing Arithmetic C. Sanitation, Plumbing Design, and Installation D. Plumbing Code
Correct answer: Practical Problems Source: RA 1378 Additional info: - Old Practical Subject included 2 parts: -- Practical Problems 20% -- Oral Practice Problems and Experience- 20%
31
An open return bend usually made up of two 90° bends A. Double offset bend B. Return bend C. Double-bend fitting D. Offset
B. Return bend
32
What is the standard length of Galvanized Iron Pipe? A. 6 m B. 1.5 m C. 3 m D. 4 m
Correct answer: 6 m Source: PDE by Max Fajardo
33
What is the standard length of vitrified clay pipes?
0.75 m
34
What is the standard length of length of cast iron?
1.5 m
35
What is the standard length of length of PPR?
4m
36
What is the standard length of length of PVC?
3m
37
Tube made of plastic material and colored black. The cross-sectional shape is normally oval and is denoted by its outside diameter or 0.D. A. Polyethylene B. Polyvinyl Chloride C. Polybutylene D. Acrylonitrile-Butadiene-Styrene
C. Polybutylene
38
Elastomeric gasketed and rubber-ring joints shall comply with _____ installation standard A. ASTM B. NAMPAP C. IAPMO D. ANSI
C. IAPMO
39
1 fixture unit is equal to? A. 7.48 gallons per minute B. 28.3 gallons per minute C. 1 cu.m per minute D. 7.48 liters per minute
Correct answer: 7.48 gallons per minute - 1 FU is also equal to 28.3 liters per minute and 1 cu.ft per minute
40
The distance of water closet or bidet center to center A. 0.30 m B. 0.75 m C. 0.60 m D. 0.375 m
Correct answer: 0.75 m Source: RNPCP, Chapter 4
41
Distance of water closet or bidet center to side
0.375 m
42
Distance or urinal to urinal center to center
0.6 m
43
Distance of urinal to side wall center to side
0.3 m
44
A hose connection with two-gated outlets permitting two connections of the same or smaller coupling diameter to be taken from a single supply line. A. Tapped Tee B. Wye C. Return Bend D. Siamese
Wye
45
Wiped lead joints shall have an exposed surface on each side of a joint not less than _____. A. 25.4 mm B. 3.2 mm C. 51 mm D. 19 mm
19 mm
46
Color for Type M copper pipe A. Red B. Green C. Yellow D. Blue
A. Red
47
The year when NAMPAP was organized and registered with the Securities and Exchange Commission A. 1935 B. 1965 C. 1956 D. 1940
A. 1935
48
All plumbing plans, drawings, diagrams, etc. shall be submitted in ___ sets for permit application. A. 4 B. 6 C. 3 D. 2
B. 6
49
Date of the Accreditation of NAMPAP A. January 28, 1954 B. September 18, 1985 C. October 2, 1975 D. January 28, 1959
October 2, 1975
50
The Old Fire Code of the Philippines A. PD 223 B. PD 1185 C. RA 9514 D. PD 1096
Correct answer: PD 1185
51
Creation of Professional Regulation Commission
PD 223
52
The 2008 Fire Code of the Philippines
RA 9514
53
National Building Code of the Philippines
PD 1096
54
Copper tubing shall be fully externally protected with a/an _____ and fiberglass wrapping installed inside a split rigid casing whenever installed underground. A. metal pipe sleeve B. bitumastic coating C. polyethylene sheath D. expansion joint
Correct answer: bitumastic coating Source: RNPCP, Chapter 6
55
protection from breakage for piping passing under or through walls
Embedded metal pipe sleeves
56
protection from external corrosion for pipes passing through or under cinders or other corrosive materials
Polyethylene sheath
57
for voids between pipes and sleeves through concrete floors in the ground
Bitumen
58
for pipes directly embedded in concrete and masonry walls
Metal sleeve
59
(ANSI) Pipe Color code for Fire Quenching A. Red with White Lettering B. White with Red Lettering C. Red with Black Lettering D. Orange with Black Lettering
Correct answer: Red with White Lettering Source: ANSI
60
Orange PIPE with Black Lettering
(ANSI/ASME) Pipe Color code for Toxic or Corrosive liquids, acids (Nitric Acid)
61
The birth of the plumbing profession in the Philippines is traced back to the ___ century. A. 17th B. 18th C. 20th D. 19th
A. 17th
62
Any change, addition or modification in construction or occupancy A. Alteration B. Renovation C. Improvement D. Repair
Correct answer: Alteration Source: RNPCP, Chapter 2
63
the reconstruction or renewal of any part of an existing building for its maintenance
Repair
64
Every building where _____ shall have a sewer service connection to a public or private sewer systems. A. solid wastes are discharged B. plumbing fixtures are installed C. there is more than 1 occupant D. at least 1 toilet room is present
Correct answer: plumbing fixtures are installed Source: RNPCP Principles (Principle #5)
65
Depth of the molten pig lead in a caulked joint A. 25.4 mm B. 51 mm C. 19 mm D. 3.2 mm
A. 25.4 mm
66
Integrated within an air accumulator vessel which is designed to discharge a predetermined quantity of water into fixtures for flushing purposes A. Flush Tank B. Flush Valve C. Flushometer Valve D. Flushometer Tank
Correct answer: Flushometer Tank Source: RNPCP, Chapter 2
67
a tank located above or integral with water close3t, urinal, or similar fixtures for flushing or removing excrements in the fixture
Flush tank
68
a device located at the bottom of the tank for the purpose of flushing water closet and similar fixtures
Flush valve
69
a device with discharges a predetermined quantity of water into fixtures for flushing purposes and is actuated by direct water pressure
Flushometer Valve
70
What will happen if a drainage piping is placed at slope of 10mm/m due to structural conditions? A. Increase in DFU loading B. Decrease in drainage piping length C. Decrease in DFU loading D. Increase in drainage piping length
Correct answer: Decrease in DFU loading Source: RNPCP, Chapter 7 Additional info: - 1% slope will require lesser DFU loading - If using 1% or 10mm/m slope, multiply the allowable DFU of horizontal drain stated in Table 7-5 by a factor of 0.8 - drainage slope does not affect length
71
A water heater is classified as? A. Plumbing Appurtenance B. Receptor C. Fixture D. Plumbing Appliance
D. Plumbing Appliance
72
The Administrative Authority must be notified at least ___ working days before such inspection is intended. A. 3 B. 8 C. 7 D. 2
A. 3
73
Common maximum service temperature rating of PVC A. 180 deg. F B. 160 deg. F C. 140 deg. F D. 120 deg. F
Correct answer: 140 deg. F
74
maximum temperature rating is 180 deg.F
CPVC
75
The following are grounds for non-issuance of the certificate of registration by the Board of Master Plumbers except for _____. A. failure to pay the required fees B. convicted by court for any criminal offense C. having an unsound mind D. guilty of immoral or dishonorable conduct
Correct answer: failure to pay the required fees (not a ground) Source: RA 1378
76
A pipe or conduit for carrying sewage and wastewater . A. Main Sewer B. Drain C. Sewer D. Drainage System
C. Sewer
77
Vertical support of _____ is placed not less than every other storey height. A. Copper Tubing B. Plastic pipe C. Screwed Pipe D. Cast Iron Soil Pipe
Correct answer: Screwed Pipe Source: RNPCP, Chapter 3
78
every storey or closer
Cast iron soil pipe, B&S Hubless Pipe
79
Each storey or maximum 3 m on center
Copper Tubing
80
Every 1 meter
Plastic Pipe
81
Who is the current chairman of the Board of Examiners for Master Plumber? A. Pedrito D. Camilet, Jr. B. Prospero A. Abellano C. Reynald B. Ilagan D. Valentino M. Mangila
Correct Answer: Reynaldo B. Ilagan Source: prc.gov
82
Member of the current Board for Master Plumbers
Pedrito D. Camilet, jr
83
former Chairman of the Board for Master Plumbers
Valentino M. Mangila
84
former Member of the Board for Master Plumbers
Prospero A. Abellano
85
Minimum weight of a lead for flashing or vent terminals A. 12.86 kg B. 14.63 kg per sqm C. 6.8 kg D. 19.56 kg per sqm
14.63 kg per sqm
86
The top edge of a receptacle from where water overflows. A. Flood Level B. Flood Level Rim C. Effective Opening D. Rim
B. Flood Level Rim
87
Distance of bottom of all pipe tranches to the footing of any adjacent building or structure parallel to it A. 90 degrees B. 45 degrees C. 600 mm D. 900 mm
B. 45 degrees
88
Which authority is responsible for the administration and enforcement of the National Plumbing Code? A. Professional Regulatory Board for Master Plumbers B. Plumbing Official C. Department of Public Works and Highways D. Professional Regulation Commission
Correct answer: Plumbing Official (Administrative Authority) Source: IRR of RA 1378 Additional info: - The Professional Regulatory Board for Master Plumbers is in-charge of the enforcement and implementation of RA 1378 and its IRR.
89
A registered master plumber must not supplant another Registered Master Plumber after definite steps have already been taken toward his/her being commissioned to perform the contract A. Code of Ethics no. 1 B. Code of Ethics no. 4 C. Code of Ethics no. 5 D. Code of Ethics no. 2
Code of Ethics no. 2